▲0 rating0 commentsKangrim boiler: "Flame failure" alarm while stopped, will not resetTroubleshootingBoiler · Kangrim · Flame failureFLAME FAILURE alarm came up while the boiler was stopped (not firing). The alarm could not be reset. A restart did not help.Anonymous · 2 y▲0 rating0 commentsGenerator will not come off the bus at stop: "Stop failure", reverse powerTroubleshootingElectrical · Stop failureThe undervoltage (UV) coil of a generator air circuit breaker (ACB) was burnt. To keep the breaker usable, the UV coil plunger was held in with its mechanical lock. The generator synchronised and…Anonymous · 1 y▲0 rating0 commentsScrubber: "CEMS failure" alarm every 4 minutes, no alarm on the SICK analyserTroubleshootingOther · SICK CEMS · CEMS failureThe scrubber panel shows "CEMS failure" about every 4 minutes. Sometimes there is no alarm for about 20 minutes, then it comes back. The CEMS itself shows no new alarm. Its status goes to Stop and…Anonymous · 3 y▲0 rating0 commentsScania generator (DEC2): fires 2 or 3 times at start, then fuel is cut offTroubleshootingAuxiliary Engine · Scania, DEC2 digital engine controlThe diesel generator cranks and fires 2–3 times, as if trying to start. Then the fuel supply stops and the engine does not start. Fuel comes back only after the DEC2 digital engine control system…Anonymous · 6 y▲0 rating0 commentsInert gas oxygen analyzers keep failing: a care routine that worksProcedureFire & SafetyInert gas (IG) oxygen analyzers that fail again and again are, in my view, usually handled badly or not maintained correctly; this is the care routine I use to prevent it. Repeated failures with…Anonymous · 4 y▲0 rating0 commentsNorimos 1000: "Signal syst. power F." alarm and all ventilation stopsTroubleshootingElectrical · Noris Norimos 1000 · SIGNAL SYST.POWER F.The alarm panel showed "SIGNAL SYST.POWER F." (signal system power failure). Right after it, all ventilation stopped. The ship was rolling.Anonymous · 7 y▲0 rating0 commentsVolvo Penta D16: con-rods through crankcase from swapped big-end caps (Wight Sky)IncidentMain Engine · Volvo Penta D16 MH · ME2 low LO pressure shutdown; ME4 common alarmRo-ro ferry with four Volvo Penta D16 MH high-speed MEs; one or two drive each Voith Schneider unit through fluid couplings. Wight Sky had three catastrophic ME failures in 15 months. The 2017 one…Anonymous · 4 y▲0 rating0 commentsGenerator con-rod seizes and holes the block: oil run far past interval (Ocean Navigator)IncidentAuxiliary Engine · Caterpillar 3516B · ER fire alarm, AE2 low LO pressure and oil filter plugged, blackoutAE2 on a coastal cruise ship (Caterpillar 3516B, 1,800 rpm) had run its LO for more than 5,000 h and its filter elements for 3,329 h. Both should be changed at 1,000 h (LO longer only under…Anonymous · 1 y▲0 rating0 commentsMAN 48/60: con-rod small end breaks after bad bush renewal (Finlandia Seaways)IncidentMain Engine · MAN 12V48/60 · Crankcase oil mist high, No. 6 main bearing temp highRo-ro at sea, single MAN 12V48/60 at 500 rpm, 110 662 running hours. The on-watch 3/E was in the purifier room when he heard loud metallic knocking. The bridge felt heavy vibration and saw pitch and…Anonymous · 5 y▲0 rating0 commentsGenerator engine fails on non-OEM bearings run to OEM intervals (Kommandor Susan)IncidentAuxiliary Engine · Caterpillar 3516B-TA · ER fire alarm, blackoutDiesel-electric vessel on sea trials, just out of the lock at Leith with a pilot on board. DG1 and DG4 were on line. The C/E heard a change in engine note on one generator, then a loud bang. The fire…Anonymous · 6 mo▲0 rating0 commentsStandard bearing shell on an undersize journal: con-rods break out (Ocean Guardian)IncidentAuxiliary Engine · Caterpillar 3516B · No alarm; loud bang, then smoke and fire in ERDiesel-electric offshore supply vessel, four Caterpillar 3516B main DGs (1,990 kW each). All four were overhauled by shore technicians in early 2022. On sea trials, DG3 had run about 4 h since…Anonymous · 3 y▲0 rating0 commentsOil tanker aux boilers: tests before cargo dischargeProcedureBoilerBefore cargo discharge on an oil tanker, I test the auxiliary boilers so they keep working through the discharge: boiler water, controls, and the pumps under load. This applies to any boiler maker…Anonymous · 4 y▲0 rating0 commentsCO2 system: leaking cylinder valves release the whole bank (Eddystone, Red Eagle)IncidentFire & Safety · Schmöle K85-50 (Eddystone), DAB D10963 with D10964 actuator (Red Eagle) · CO2 release alarm, hissing in CO2 roomTwo UK ro-ro ships, same failure: nobody touched the CO2 release, but a bank emptied itself into the CO2 room. Eddystone was in the Southern Red Sea, ambient 32 °C. The CO2 release alarm sounded with…Anonymous · 8 y