▲0 rating0 commentsBWTS valve with Siemens SIPART PS2 positioner: alarm A29, valve limit switchTroubleshootingBallast System · Siemens SIPART PS2 6DR5020-0NG30-0AB0 · A29The ballast water treatment system gave alarm A29: limit switch fault on a valve. The limit switch is inside the valve positioner, wired to terminals 41–42.Anonymous · 6 y▲0 rating0 commentsMitsubishi deck crane will not start after a limit switch stopTroubleshootingDeck Machinery · MitsubishiThe crane limit switches were being tested during a class survey. A limit switch tripped and the crane stopped. After that the crane would not start at all. There were no alarms.Anonymous · 1 y▲0 rating0 commentsRolls-Royce steering gear: one pump stops the rudder at 10° to one sideTroubleshootingSteering Gear · Rolls-RoyceWith one of the two pumps, the rudder would not go more than 10° to one side. Same in follow-up and non-follow-up. It stopped at exactly 10° every time, from any starting position. Pushing the…Anonymous · 7 y▲0 rating0 commentsNabtesco governor: main engine will not go above 66 rpm, SCAVEN. LIMIT lamp onTroubleshootingMain Engine · Nabtesco governor control unit · M/E GOVERNOR SYSTEM ABNRThe main engine would not run faster than 66 rpm (Half Ahead). Scavenge air pressure was 0.2 bar. The auxiliary blowers were still running. On the governor control unit the SCAVEN. LIMIT lamp was on.…Anonymous · 3 y▲0 rating0 commentsHyundai lift works only in Manual or Inspection mode, not in Auto, no alarmTroubleshootingOther · Hyundai ElevatorIn heavy pitching, the ship slammed into a wave with strong vibration. The lift stopped at that moment. The car was brought down in Manual mode and the breaker was switched off. After switching on…Anonymous · 6 y▲0 rating0 commentsNorimos 1000: "Signal syst. power F." alarm and all ventilation stopsTroubleshootingElectrical · Noris Norimos 1000 · SIGNAL SYST.POWER F.The alarm panel showed "SIGNAL SYST.POWER F." (signal system power failure). Right after it, all ventilation stopped. The ship was rolling.Anonymous · 7 y▲0 rating0 commentsEngine room fan trips its breaker when the soft starter switches to bypassTroubleshootingRefrigeration & HVAC · Schneider Altistart 48 (ATS48)The main engine room supply fan is reversible and is started by a soft starter with a bypass contactor. The soft starter ran the fan up normally in about 15 seconds. At the moment the bypass…Anonymous · 1 y▲0 rating0 commentsBoll & Kirch filter turns back to the dirty chamber at flushingTroubleshootingOther · Boll & Kirch 6.72, BK 2200 controllerAt backflushing: The solenoid worked and the filter turned to the clean chamber. The solenoid switched off, air was cut, and the filter turned back to the dirty chamber. This happened twice in a row.…Anonymous · 5 y▲0 rating0 commentsHow to take one cylinder out of service on MAN ME-CProcedureMain Engine · MAN ES ME-CTo take one cylinder unit out of operation on an ME-C (electronically controlled 2-stroke) main engine, I set the Chief Index limit for that cylinder to 0 on the MOP. This is an outline only. The…Anonymous · 4 y▲0 rating0 commentsMacGregor crane: alarm 93 "Encoder wrong position", crane stopsTroubleshootingDeck Machinery · MacGregor · 93 Encoder wrong positionAlarm 93 "Encoder wrong position" on the hoisting and luffing MPC. After one MPC was replaced, the alarm still came, but the crane could be operated. An hour later the alarm came again and the crane…Anonymous · 4 y▲0 rating0 commentsHFO to MGO changeover: cool slowly and watch viscosityProcedureMain EngineChanging the main engine and diesel generators from HFO to MGO is safe if fuel temperature falls slowly and viscosity stays between 2 cSt and 20 cSt. This is the general procedure I use; it follows…Anonymous · 3 y▲0 rating0 commentsShipboard incinerator: how to keep it in good conditionKnowledgeIncinerator & SewageKeeping a shipboard incinerator in good condition mostly means clean air inlets and burner parts, a slow shutdown, careful sludge handling and sensible loading. These are the practices I follow,…Anonymous · 4 y▲0 rating0 commentsEmergency generator breaker closes and opens again at once, no tripTroubleshootingElectrical · Schneider Masterpact NT06 H2, Micrologic 5.0 AThe emergency generator breaker would not stay closed on the emergency switchboard bus, in both auto and manual mode. On "close" the breaker clicked and closed. The green "closed" indication was on…Anonymous · 4 y▲0 rating0 commentsDoppler speed log: water track vs bottom trackKnowledgeNavigationWater track and bottom track on a Doppler speed log use the same Doppler principle; the only difference is the surface that reflects the signal. This note covers how the log works in each mode.…Anonymous · 1 y▲0 rating0 commentsThermal oil fire from a failing pump bearing, water mist did not work (Pride of Hull)IncidentPumps · Allweiler NTT 80-200 · ER fire alarm, zone "Oil treatment pumps"Ro-ro passenger ferry, outbound in the Humber. Thermal oil (Texatherm 32, winter set point 170 °C) carried heat from the economisers and a boiler. Circulation pump #1 was on duty. The fire panel…Anonymous · 4 y▲0 rating0 commentsMAN B&W main engine in heavy weather: torque vs rpm governor modeKnowledgeMain Engine · MAN B&W ME-B / ME-C, MCTo protect the main engine liners and piston rings in heavy weather, I reduce RPM and choose the governor mode with care: on ME-B and ME-C engines that means weighing Torque mode against RPM mode.…Anonymous · 3 y▲0 rating0 commentsPods stuck at 90° after overspeed trip and a latched water-leak stop (Spirit of Discovery)IncidentPropulsion & Thrusters · Siemens SISHIp eSiPOD (SiPOD-M10) · Pod water leakage stop (WLS) sequence alarm, then propeller overspeedCruise ship with two Siemens eSiPOD pods (6,500 kW each, no rudder), crossing the Bay of Biscay in force 8–9 wind and 8–9 m waves. At 12:30 the port pod gave a WLS sequence alarm. Very soon after, it…Anonymous · 8 mo▲0 rating0 commentsMAN ME: internal leak test on the hydraulic systemProcedureMain Engine · MAN ES ME-type main engineThis procedure is for MAN ES main engines with electronic control (ME type). It covers the hydraulic power supply (HPS) pumps, the hydraulic cylinder units (HCU) and the safety and accumulator block.…Anonymous · 4 y