▲0 rating0 commentsScania generator (DEC2): fires 2 or 3 times at start, then fuel is cut offTroubleshootingAuxiliary Engine · Scania, DEC2 digital engine controlThe diesel generator cranks and fires 2–3 times, as if trying to start. Then the fuel supply stops and the engine does not start. Fuel comes back only after the DEC2 digital engine control system…Anonymous · 6 y▲0 rating0 commentsSiemens LOGO! fuel changeover: program loaded but does not runTroubleshootingAutomation / PLC · Siemens LOGO! 230RC with DM8 230R and AM2 expansion modules · Control failThe automatic HFO/MDO changeover (valves and fuel heating) is controlled by a Siemens LOGO! 230RC with expansion modules. A "Control fail" alarm came up on the fuel page of the control PC. Expansion…Anonymous · 3 y▲0 rating0 commentsMAN ME-C: running with one HPS pump in fail modeKnowledgeMain Engine · MAN Energy Solutions ME-CWith one of three HPS pumps in "fail", an ME-C main engine can usually keep full function if the fault is only electronic or in the cables; a mechanical fault is a different case. These are my notes…Anonymous · 3 y▲0 rating0 commentsAlpha Lubricator: "Feedback failure" slowdown comes and goesTroubleshootingMain Engine · MAN B&W Alpha Lubricator · Feedback failureMain engine slowdown from the Alpha Lubricator system, alarm "Feedback failure". The alarm came for 5 to 60 seconds and then cleared by itself. In the menu it showed as Alarm 3. By the manual, Alarm…Anonymous · 4 y▲0 rating0 commentsSauer air-cooled service air compressor overheats (105 °C)TroubleshootingCompressed Air · Sauer Compressors, Air Control 1 controllerThe air-cooled service air compressor overheated. The controller showed 105 °C at 5.6 bar.Anonymous · 2 y▲0 rating0 commentsWeishaupt Monarch burner: random "Air combustion low" at startTroubleshootingBoiler · Weishaupt Monarch · Air combustion lowThe burner tripped only at boiler start, two or three times a day. The alarm changed: sometimes "Air combustion low", sometimes "Flame failure". It was random: no alarm for 10 hours, then up to five…Anonymous · 4 y▲0 rating0 commentsStern tube air seal: risk of losing air supply at deep draftKnowledgePropulsion & ThrustersLoss of the air supply to a stern tube air seal is a serious condition, because at deep draft the oil head alone may not hold back seawater and seawater may enter the stern tube. Loss of air supply…Anonymous · 3 y▲0 rating0 commentsAalborg boilers: local panels go offline, fan trips at ignitionTroubleshootingBoiler · AalborgTwo boilers, one ECR PC. First the boiler 1 local panel went offline now and then; a reset helped for a day. Then the boiler 2 local panel went offline, flashing online / offline, and did not reset.…Anonymous · 6 y▲0 rating0 commentsThermal oil fire from a failing pump bearing, water mist did not work (Pride of Hull)IncidentPumps · Allweiler NTT 80-200 · ER fire alarm, zone "Oil treatment pumps"Ro-ro passenger ferry, outbound in the Humber. Thermal oil (Texatherm 32, winter set point 170 °C) carried heat from the economisers and a boiler. Circulation pump #1 was on duty. The fire panel…Anonymous · 4 y▲0 rating0 commentsNMF deck crane: no POWER REQUEST after flooding, CPU blinks RUN/STOPTroubleshootingDeck Machinery · NMF crane, Moeller XC-CPU201The cranes were badly flooded: slip rings and control panels. Slip rings and panels were cleaned and dried. The cranes had been without power for 2 days. Cranes 1 and 3 started. On crane 2 the POWER…Anonymous · 3 y▲0 rating0 commentsDEIF PPM-3: busbar voltage read too low, generator will not auto-synchroniseTroubleshootingAutomation / PLC · DEIF PPM-3The DEIF PPM-3 controller of one generator measured the busbar voltage lower than it really was. The PMS saw a voltage fault. Auto synchronising was not possible, only manual. When the measured…Anonymous · 2 y▲0 rating0 commentsME exhaust valve spindle burn-through: common causesKnowledgeMain EngineExhaust valve spindle burn-through on a two-stroke main engine usually comes from one of a short list of factors, each of which makes the spindle burn away faster and shortens the time between…Anonymous · 4 y▲0 rating0 commentsEmergency generator breaker closes and opens again at once, no tripTroubleshootingElectrical · Schneider Masterpact NT06 H2, Micrologic 5.0 AThe emergency generator breaker would not stay closed on the emergency switchboard bus, in both auto and manual mode. On "close" the breaker clicked and closed. The green "closed" indication was on…Anonymous · 4 y▲0 rating0 commentsOil tanker aux boilers: tests before cargo dischargeProcedureBoilerBefore cargo discharge on an oil tanker, I test the auxiliary boilers so they keep working through the discharge: boiler water, controls, and the pumps under load. This applies to any boiler maker…Anonymous · 4 y▲0 rating0 commentsCPP hub oil loss from a cracked blade foot, not a blade seal (Maunalei)IncidentPropulsion & Thrusters · MAN Energy Solutions Mark 5 CPP; MAN B&W 7L70MC-C · Engineering alarm, CPP hub head tank found emptyContainership, MAN B&W 7L70MC-C two-stroke ME directly coupled to a 5-blade MAN Mark 5 CPP. On passage to Anchorage an alarm came up: CPP hub head tank empty. The crew reduced pitch and refilled the…Anonymous · 2 y▲0 rating0 commentsMain engine EGR: deposits and wear depend mainly on fuel sulphurKnowledgeMain EngineOn a two-stroke main engine EGR (exhaust gas recirculation) system, fuel sulphur content is the main factor behind deposits in the air cooler and scavenge receiver and the amount of drain water and…Anonymous · 4 y▲0 rating0 commentsWhy anchors and anchor chains are lost or damagedKnowledgeDeck MachineryAnchors and chains are lost or damaged through a mix of technical wear, operational mistakes and use beyond the design limits of the equipment. This is a general note, not one fault case. When…Anonymous · 4 y▲0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y