▲0 rating0 commentsKongsberg DGU 8800e governor switches off a few minutes after startTroubleshootingMain Engine · Kongsberg DGU 8800eThe main engine governor unit would not stay on. After the power button inside the unit, two green LEDs lit. The unit tried to boot, then switched off. When cold (after being off for a while), it…Anonymous · 4 y▲0 rating0 commentsOceanGuard BWTS: "EUT Power Abnormal" 10 s after startTroubleshootingBallast System · OceanGuard · EUT Power Abnormal AlarmThe BWTS worked normally 3 days before. Now, about 10 seconds after start, the alarm "EUT Power Abnormal Alarm" came up and the system stopped. The EUT power unit got its supply: LEDs on all modules…Anonymous · 3 y▲0 rating0 answersMAN B&W ME: "Large deviation from model curve" alarm, worn HPS valves suspectedTroubleshootingOpenMain Engine · MAN B&W ME (electronic engine), exact model not stated · Large deviation from model curveThe "Large deviation from model curve" alarm on a MAN B&W ME engine most often points to a worn or defective proportional valve on an HPS pump. That is my working suspicion for the alarm on our…Anonymous · 3 y▲0 rating0 commentsMAN B&W ME: HPS pressure build-up time and decay checkKnowledgeMain Engine · MAN B&W MEOn a MAN B&W ME engine with one start-up pump running, I take an HPS pressure build-up time under 30 s as acceptable, and I also check the pressure decay time. The full maker requirements are in the…Anonymous · 3 y▲0 rating0 commentsNorimos 1000: "Signal syst. power F." alarm and all ventilation stopsTroubleshootingElectrical · Noris Norimos 1000 · SIGNAL SYST.POWER F.The alarm panel showed "SIGNAL SYST.POWER F." (signal system power failure). Right after it, all ventilation stopped. The ship was rolling.Anonymous · 7 y▲0 rating0 commentsBallast valve remote control: half the valves stop responding, no alarmTroubleshootingBallast System · Utsuki valve remote control, Yokogawa FA-M3 PLCAbout half of the hydraulic ballast valves stopped responding, all at the same time. No reaction from the ballast console or from the local control panel. No alarms. The valves could still be moved…Anonymous · 6 y▲0 rating0 commentsHow to check that the AIS transponder is workingProcedureNavigationA simple routine check confirms the shipboard AIS is working: distant targets show the receiver is good, and other ships confirming they see you shows the transmitter and antenna are good. This is…Anonymous · 4 y▲0 rating0 commentsAalborg thermal oil boiler: no fuel from the nozzle at ignitionTroubleshootingBoiler · Aalborg, LAL burner controlAfter a safety alarm test the boiler stopped and did not start again. The coil of the recirculation (return) solenoid valve had burnt. It had run hot for a long time: it looked melted and its wiring…Anonymous · 1 y▲0 rating0 commentsMAN ME: internal leak test on the hydraulic systemProcedureMain Engine · MAN ES ME-type main engineThis procedure is for MAN ES main engines with electronic control (ME type). It covers the hydraulic power supply (HPS) pumps, the hydraulic cylinder units (HCU) and the safety and accumulator block.…Anonymous · 4 y▲0 rating0 commentsEngine room flooding from a corroded sea water pipe at the strainer (Oliver Hazard Perry)IncidentAuxiliary Engine · John Deere diesel generator · AC power fault alarm on fire alarm panel, blackoutSail training tall ship (128 ft), two Caterpillar C12 propulsion engines, two John Deere DGs (99 kW). Moored, one crewmember on board. Shore power breakers kept tripping, so the port DG ran…Anonymous · 7 mo▲0 rating0 commentsUsing a new bunker before the lab report arrives: precautionsProcedureMain EngineWhen a ship has to change over to a new bunker before the lab report arrives, I treat the fuel as suspect and run with extra precautions on fuel treatment and engines until the result is known. The…Anonymous · 4 y▲0 rating0 commentsFire pump 115 kW: main breaker trips at star-delta changeoverTroubleshootingPumpsTwo fire pumps, 115 kW each. One starts normally. The other runs up on star without problems. At the changeover to delta, the main breaker trips. At the changeover, the current goes off the scale of…Anonymous · 6 y▲0 rating0 commentsTwo-stroke main engine: jobs to do while stopped in port or at anchorKnowledgeMain Engine · MAN ES ME / MCThis is my checklist of jobs to plan when the two-stroke main engine is stopped in port or at anchor and there is a good chance to do the work. It leaves out inspections that are due by running…Anonymous · 4 y▲0 rating0 commentsMacGregor crane: slewing stops with "60 Joystick level error"TroubleshootingDeck Machinery · MacGregor crane, MPC control cards · 60 Joystick level error (normal is 1,5 to 10,5V)The slewing card showed error 60 "Joystick level error (normal is 1,5 to 10,5V)". The crane stopped because of this error.Anonymous · 6 y▲0 rating0 commentsMAN ME-C: running with one HPS pump in fail modeKnowledgeMain Engine · MAN Energy Solutions ME-CWith one of three HPS pumps in "fail", an ME-C main engine can usually keep full function if the fault is only electronic or in the cables; a mechanical fault is a different case. These are my notes…Anonymous · 3 y▲0 rating0 commentsMAN ME HCU and HPS event logs: compare only with the same engineKnowledgeMain Engine · MAN Energy Solutions ME (electronically controlled)HCU and HPS event logs from the MOP are a useful troubleshooting tool on MAN ES ME engines, but you can only compare events from the same engine. These are my notes on what the events are, how I view…Anonymous · 3 y▲0 rating0 commentsInert gas oxygen analyzers keep failing: a care routine that worksProcedureFire & SafetyInert gas (IG) oxygen analyzers that fail again and again are, in my view, usually handled badly or not maintained correctly; this is the care routine I use to prevent it. Repeated failures with…Anonymous · 4 y▲0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y