▲0 rating0 commentsBoiler burner smokes, and more air makes it worseTroubleshootingBoilerThe boiler was smoking. Adding more combustion air made the smoke worse. The burner is set to run on the first stage only. The second stage was switched off on the panel.Anonymous · 3 y▲0 rating0 commentsIncinerator will not light: thick white smoke, flame sensor drops outTroubleshootingIncinerator & SewageThe incinerator would not light. The flame sensor lost the flame. Before, it had worked every day. The furnace had not been cleaned for a long time. Both chambers were full of ash, and all the air…Anonymous · 3 y▲0 rating0 commentsFire detection: fault on loop point 2.6, but all loop detectors test OKTroubleshootingFire & SafetyThe fire detection panel showed a fault on loop 2, point 2.6. The ship was in a storm.Anonymous · 6 y▲0 rating0 commentsAutronica: loop fault on Ex detector stays after barrier replacementTroubleshootingFire & Safety · Autronica, BZB 500 interface unit · LOOP FAULTS: LOOP 01 / POINT FAULTS: 10106 SD(EXI)Open-circuit fault on the paint store detector line. The panel showed "LOOP FAULTS 1 LOOP 01" and "POINT FAULTS 1 10106 SD(EXI)". The system did not see the detector.Anonymous · 1 y▲0 rating0 commentsConsilium CS4000: false fire alarm in cargo hold keeps coming backTroubleshootingFire & Safety · Consilium CS4000 · FIRE ALARM — FIRE ZONE 31 IS-DET 43Fire alarm from a cargo hold zone, but there was no fire. The Fault LED was also lit. After a reset the alarm came back the next morning and then would not reset. A full system restart did not help.…Anonymous · 6 mo▲0 rating0 commentsEngine room fire: fuel backflow through an open return line (Scot Stuttgart)IncidentAuxiliary Engine · "" · ER fire alarm, thick white smoke in port ERChemical tanker with two engine rooms, alongside in San Juan discharging cargo. The port AE was under LOTO for turbocharger and aftercooler cleaning. The crew removed the aftercooler and the fuel…Anonymous · 2 mo▲0 rating0 commentsAux engine room fire: slipped fuel pump coupling and exhaust leak (Finnmaster)IncidentAuxiliary Engine · Mitsubishi S12R · ER smoke alarm, then blackoutRo-ro leaving Hull with a pilot on board. AE1 had just been paralleled with AE2. Eight minutes after leaving the berth, smoke was detected in the aux engine room. Both AE2 exhaust temperature gauges…Anonymous · 1 y▲0 rating0 commentsStandard bearing shell on an undersize journal: con-rods break out (Ocean Guardian)IncidentAuxiliary Engine · Caterpillar 3516B · No alarm; loud bang, then smoke and fire in ERDiesel-electric offshore supply vessel, four Caterpillar 3516B main DGs (1,990 kW each). All four were overhauled by shore technicians in early 2022. On sea trials, DG3 had run about 4 h since…Anonymous · 3 y▲0 rating0 commentsFatal engine room fire after opening a pressurised fuel filter (Moritz Schulte)IncidentAuxiliary Engine · MAN B&W L23/30H · ER fire alarmLPG carrier discharging alongside in Antwerp. AE2 and AE3 were running and AE1 was on standby. After the morning toolbox talk the newly promoted 3/E asked the 2/E if he could clean the AE1 fuel…Anonymous · 3 y▲0 rating0 commentsConsilium fire detection: five "Sensor fail" alarms from one zoneTroubleshootingFire & Safety · Consilium · Sensor fail, Communication errorFive "Sensor fail" alarms with "Communication error" came up suddenly, all from one zone (pump room). The failed points were on two loops: 3 smoke detectors on loop 2 and 2 manual call points on loop…Anonymous · 6 y▲0 rating0 commentsMAN 48/60: con-rod small end breaks after bad bush renewal (Finlandia Seaways)IncidentMain Engine · MAN 12V48/60 · Crankcase oil mist high, No. 6 main bearing temp highRo-ro at sea, single MAN 12V48/60 at 500 rpm, 110 662 running hours. The on-watch 3/E was in the purifier room when he heard loud metallic knocking. The bridge felt heavy vibration and saw pitch and…Anonymous · 5 y▲0 rating0 commentsMAN 6S50ME-C: unit loses compression 10 minutes after overhaulTroubleshootingMain Engine · MAN B&W 6S50ME-CUnit 1 of the main engine was overhauled. Tests in port were normal. About 10 minutes after leaving port, the unit started knocking and lost compression. After a restart the unit worked again, but…Anonymous · 4 y▲0 rating0 commentsGenerator engine fails on non-OEM bearings run to OEM intervals (Kommandor Susan)IncidentAuxiliary Engine · Caterpillar 3516B-TA · ER fire alarm, blackoutDiesel-electric vessel on sea trials, just out of the lock at Leith with a pilot on board. DG1 and DG4 were on line. The C/E heard a change in engine note on one generator, then a loud bang. The fire…Anonymous · 6 mo▲0 rating0 commentsCummins NTA855 emergency generator: speed hunts ±30 rpm after a cold startTroubleshootingAuxiliary Engine · Cummins NTA855-D(M)On the first cold start, speed hunted by about ±30 rpm at 1800 rpm (frequency by about 0.5 Hz). After a restart (sometimes the 2nd or 3rd) it ran smoothly, and further starts were fine. A few hours…Anonymous · 1 y▲0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y▲0 rating0 commentsThermal oil fire from a failing pump bearing, water mist did not work (Pride of Hull)IncidentPumps · Allweiler NTT 80-200 · ER fire alarm, zone "Oil treatment pumps"Ro-ro passenger ferry, outbound in the Humber. Thermal oil (Texatherm 32, winter set point 170 °C) carried heat from the economisers and a boiler. Circulation pump #1 was on duty. The fire panel…Anonymous · 4 y▲0 rating0 commentsVolvo Penta D16: con-rods through crankcase from swapped big-end caps (Wight Sky)IncidentMain Engine · Volvo Penta D16 MH · ME2 low LO pressure shutdown; ME4 common alarmRo-ro ferry with four Volvo Penta D16 MH high-speed MEs; one or two drive each Voith Schneider unit through fluid couplings. Wight Sky had three catastrophic ME failures in 15 months. The 2017 one…Anonymous · 4 y▲0 rating0 commentsGenerator con-rod seizes and holes the block: oil run far past interval (Ocean Navigator)IncidentAuxiliary Engine · Caterpillar 3516B · ER fire alarm, AE2 low LO pressure and oil filter plugged, blackoutAE2 on a coastal cruise ship (Caterpillar 3516B, 1,800 rpm) had run its LO for more than 5,000 h and its filter elements for 3,329 h. Both should be changed at 1,000 h (LO longer only under…Anonymous · 1 y▲0 rating0 commentsDiesel oil bunkering: tank overflow through a taped vent, engine room fire (Stride)IncidentBoiler · MAN B&W 7S70MC Mk6 · Diesel oil seen dripping from upper ER; no tank high-level alarm recordedGeneral cargo ship alongside at LaPorte, Texas, taking 80 mt of LSMGO into the port and starboard double-bottom DO tanks. The C/E and 3/E ran the bunkering from the ECR, with both fill valves open.…Anonymous · 1 y