0 rating0 commentsAtlas incinerator will not burn sludge: no start signal to dosing pumpTroubleshootingIncinerator & Sewage · AtlasThe incinerator would not burn sludge. Chamber temperature rose normally and reached the set point for starting the sludge burner. But the PLC gave no output signals: no "dosing pump ready to start",…Anonymous · 6 y0 rating0 commentsOil tanker aux boilers: tests before cargo dischargeProcedureBoilerBefore cargo discharge on an oil tanker, I test the auxiliary boilers so they keep working through the discharge: boiler water, controls, and the pumps under load. This applies to any boiler maker…Anonymous · 4 y0 rating0 commentsDoosan emergency generator: testing overspeed without a test buttonKnowledgeAuxiliary Engine · Doosan AD136TS, KMC ECMS-850EH · OverspeedThe set: Doosan AD136TS engine (1800 rpm, 125 kW) with a KMC ECMS-850EH engine control and monitoring system. The wiring diagram in the manual shows a GAC ESD5550 speed control unit with "TEST…Anonymous · 3 y0 rating0 commentsEmergency generator trips on blackout test, then will not close on the busTroubleshootingElectrical · Schneider Electric ComPacT NSX630Blackout test from the main switchboard: the supply to the emergency switchboard was switched off. The emergency generator started, closed onto the bus and took the load. After 5–10 minutes it…Anonymous · 6 mo0 rating0 commentsSEA-Mate B500 blender stops after blending, blend not dischargedTroubleshootingMain Engine · Marine Fluid Technology SEA-Mate Blender B500In auto mode the unit mixes the oils, then stops and stays stopped. It should open the valve and pump the blend on, but it does not. No alarm.Anonymous · 3 y0 rating0 commentsShipboard electric motors: routine maintenance checks and testsKnowledgeElectricalPreventive maintenance of shipboard electric motors comes down to daily attention plus a few periodic checks and tests. The best thing I know is an electro-technical officer (ETO) on board who…Anonymous · 4 y0 rating0 commentsDual-fuel main engine: loud bangs and many alarms when changing over to gasTroubleshootingMain EngineThe main engine was started and changed over to gas. Loud bangs from the engine and many alarms.Anonymous · 7 mo0 rating0 answersMAN B&W ME: "Large deviation from model curve" alarm, worn HPS valves suspectedTroubleshootingOpenMain Engine · MAN B&W ME (electronic engine), exact model not stated · Large deviation from model curveThe "Large deviation from model curve" alarm on a MAN B&W ME engine most often points to a worn or defective proportional valve on an HPS pump. That is my working suspicion for the alarm on our…Anonymous · 3 y0 rating0 commentsTanker P/V valves: clean often, lap pitting early, keep a spareProcedureOtherP/V (pressure/vacuum) valve care on tankers comes down to cleaning the discs and seats often, lapping pitting while it is still shallow, and always keeping a spare valve on board. A tanker is only…Anonymous · 4 y0 rating0 commentsMAN ME: internal leak test on the hydraulic systemProcedureMain Engine · MAN ES ME-type main engineThis procedure is for MAN ES main engines with electronic control (ME type). It covers the hydraulic power supply (HPS) pumps, the hydraulic cylinder units (HCU) and the safety and accumulator block.…Anonymous · 4 y0 rating0 commentsHyundai steering gear: pump stops 4 seconds after start from the bridgeTroubleshootingSteering Gear · HyundaiIn the evening the running steering gear pump stopped, and the standby pump started. Started from the bridge (autopilot), the pump motor ran for about 4 seconds and then stopped. No alarms on the…Anonymous · 3 y0 rating0 commentsMitsubishi deck crane will not start after a limit switch stopTroubleshootingDeck Machinery · MitsubishiThe crane limit switches were being tested during a class survey. A limit switch tripped and the crane stopped. After that the crane would not start at all. There were no alarms.Anonymous · 1 y0 rating0 commentsTanker fixed gas sampling system: monthly and yearly checksKnowledgeFire & SafetyThe fixed gas sampling system on an oil tanker needs monthly crew checks (visual inspection, alarm test, zero and span calibration) plus, as good practice, a yearly health check by an authorized…Anonymous · 4 y0 rating0 commentsHow to check that the AIS transponder is workingProcedureNavigationA simple routine check confirms the shipboard AIS is working: distant targets show the receiver is good, and other ships confirming they see you shows the transmitter and antenna are good. This is…Anonymous · 4 y0 rating0 commentsFuel oil purifiers: how to remove more cat finesKnowledgePurifierTo remove more catalytic fines (cat fines), fuel oil purifiers (centrifugal separators) need low throughput, the right temperature and good maintenance. These are my general notes; there is no…Anonymous · 4 y0 rating0 commentsMain switchboard low insulation: find the fault by isolating loadsProcedureElectrical · Low insulationThis is how I find the cause of a low insulation alarm or low reading on the main switchboard (MSB): isolate all loads, then reconnect them one at a time while watching the insulation monitor. It…Anonymous · 4 y0 rating0 commentsGenerator overhaul: checklist to prevent con-rod failures afterwardsProcedureAuxiliary EngineMost serious damage to an auxiliary diesel generator (D/G) comes a few hours after a general overhaul, usually from connecting rod or rod bolt failure; this is the checklist I use to prevent it. It…Anonymous · 4 y0 rating0 commentsDual-fuel VLCC: why deck LNG tanks have a water spray systemKnowledgeFire & SafetyThe water spray system around deck LNG fuel tanks has two jobs: it cools the tank and nearby structure in a fire, and it protects carbon steel deck and structure from brittle fracture if LNG leaks or…Anonymous · 4 y0 rating0 commentsMAN B&W ES main engine: precautions for long low-load runningKnowledgeMain Engine · MAN B&W ESMAN Service Letter SL09-511/MTS gives 10% load as the lowest load for continuous running of a MAN B&W ES two-stroke main engine, and running in this range needs precautions. These are the precautions…Anonymous · 4 y0 rating0 commentsBent propeller blade tip: straightening in place, then PT checkProcedurePropulsion & ThrustersA bent propeller blade tip can be straightened in place by heating, by pressing, or both, followed by a dye penetrant (PT) check. This is the outline of how I did this repair; it is not a common job.…Anonymous · 3 y