▲0 rating0 commentsAlfa Laval SA805 lube oil separator: bowl opens by itself after about 10 hoursTroubleshootingPurifier · Alfa Laval SA805 · Low back pressureThe separator ran for about 10 hours, then the bowl opened by itself. The closing water went to the drain, and nothing held the bowl closed. Alarm: "Low back pressure". The other two separators…Anonymous · 4 y▲0 rating0 commentsAC compressor loses oil pressure at start after overhaul with new partsTroubleshootingRefrigeration & HVAC · Low oil pressureThe air-conditioning compressors were overhauled with a new spare parts kit. After the overhaul, oil pressure dropped at every start.Anonymous · 1 y▲0 rating0 commentsYanmar generator: low LO pressure shutdown 5 minutes after startTroubleshootingAuxiliary Engine · YanmarAfter start, LO pressure was normal (4.8 bar), then slowly fell. After 5–6 minutes at most, the engine shut down on low LO pressure. The differential pressure indicator on the automatic LO filter…Anonymous · 4 y▲0 rating0 commentsBoiler feed pumps air-lock every few hours and trip on low pressureTroubleshootingBoilerBoiler feed water pumps get air-locked. After venting they run for 2–3 hours (sometimes up to 2 days), then the same again. Both pump motors trip. Low pressure alarms on the boiler panel, mostly at…Anonymous · 1 y▲0 rating0 commentsProvision plant compressor does not stop at pump-down, overcurrent tripTroubleshootingRefrigeration & HVACThe suction line has two low pressure switches: one stops the compressor, the other opens the unloader valve. When all cold room solenoid valves closed and suction pressure fell, the stop switch did…Anonymous · 7 y▲0 rating0 commentsAlfa Laval plate FWG: high brine temperature (60 °C) and low outputTroubleshootingFresh Water Generator · Alfa Laval (plate type)Low fresh water output and brine temperature up to 60 °C. Cleaning the plates did not help. Vacuum and heating water were normal. Readings, the same before and after cleaning: Reading Value Heating…Anonymous · 10 mo▲0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y▲0 rating0 commentsFresh water generator: checklist for low output or high salinityProcedureFresh Water GeneratorThis is my checklist for a fresh water generator (FWG) that makes too little water or gives high salinity in the distillate. It applies to a vacuum evaporator heated by engine jacket water, where an…Anonymous · 4 y▲0 rating0 commentsScrubber: "CEMS failure" alarm every 4 minutes, no alarm on the SICK analyserTroubleshootingOther · SICK CEMS · CEMS failureThe scrubber panel shows "CEMS failure" about every 4 minutes. Sometimes there is no alarm for about 20 minutes, then it comes back. The CEMS itself shows no new alarm. Its status goes to Stop and…Anonymous · 3 y▲0 rating0 commentsHimsen 6H21/32: lowering the main bearing cap far enough to change the bearingKnowledgeAuxiliary Engine · Himsen 6H21/32When the main bearing cap is lowered with the special tool as the manual says, it goes down only 7–8 cm. That is not enough to change the bearing.Anonymous · 1 y▲0 rating0 commentsTwo-stroke load diagram: why the same mep is overload at low rpmKnowledgeMain Engine · MAN B&WOn a MAN B&W two-stroke load diagram, the same mep that is fine at high RPM counts as overload at low RPM because the torque limit is set mainly by the thermal load of engine components, with weak…Anonymous · 3 y▲0 rating0 commentsScania generator (DEC2): fires 2 or 3 times at start, then fuel is cut offTroubleshootingAuxiliary Engine · Scania, DEC2 digital engine controlThe diesel generator cranks and fires 2–3 times, as if trying to start. Then the fuel supply stops and the engine does not start. Fuel comes back only after the DEC2 digital engine control system…Anonymous · 6 y▲0 rating0 commentsMAN B&W two-stroke: limits for judging engine performanceKnowledgeMain Engine · MAN B&W MC/MC-C, ME/ME-C/ME-BThis is my checklist of practical limits for judging the performance of MAN B&W two-stroke main engines, both mechanical (MC/MC-C) and electronic (ME/ME-C/ME-B). I don't have the source of the limits…Anonymous · 3 y▲0 rating0 commentsOWS 15 ppm monitor cannot detect a blocked sampling lineKnowledgeOWS & Bilge · JOWA; Bilgemon488 15 ppm monitorA 15 ppm bilge alarm without a low sample flow switch cannot tell when its sampling line is closed or blocked, so the OWS can keep discharging overboard. A poorly placed sampling point can also make…Anonymous · 3 y▲0 rating0 commentsRunning the exhaust gas economizer dry: soot fire risk and precautionsProcedureBoilerAn exhaust gas economizer (exhaust gas boiler) can be run dry in an emergency, but the main risk is a soot fire: with no water inside, the tubes run hotter. This procedure lists the precautions I…Anonymous · 3 y▲0 rating0 commentsAux boiler explosion: waxy MGO, then fan restart into a gassy furnace (Manhattan Bridge)IncidentBoiler · "" · Aux boiler emergency trip (Furnace flame-eye abnormal)A 13,900 TEU container ship was berthing at Felixstowe in winter. The auxiliary boiler (rotary cup burner) had been on MGO for three days for the ECA. It tripped four times between 17:30 and 19:51.…Anonymous · 8 y▲0 rating0 commentsMAN B&W ME-C on VLSFO: which cylinder oil BN to useKnowledgeMain Engine · MAN B&W ME-CThere is no single right cylinder oil BN for MAN B&W ME-C two-stroke engines burning VLSFO (0.5 % sulphur): results depend on the engine and on how it is run. These are my notes from about three…Anonymous · 4 y▲0 rating0 commentsGenerator overhaul: checklist to prevent con-rod failures afterwardsProcedureAuxiliary EngineMost serious damage to an auxiliary diesel generator (D/G) comes a few hours after a general overhaul, usually from connecting rod or rod bolt failure; this is the checklist I use to prevent it. It…Anonymous · 4 y▲0 rating0 commentsMAN B&W main engine in heavy weather: torque vs rpm governor modeKnowledgeMain Engine · MAN B&W ME-B / ME-C, MCTo protect the main engine liners and piston rings in heavy weather, I reduce RPM and choose the governor mode with care: on ME-B and ME-C engines that means weighing Torque mode against RPM mode.…Anonymous · 3 y