Search

Cases

0 rating0 commentsAMS Totem Plus: ME Alpha Lubricator alarms go into inhibitTroubleshootingAutomation / PLC · Totem Plus IMACSAt sea, all ME Alpha Lubricator alarms on the AMS (about 6 channels) went into inhibit by themselves. Real alarms on the Alpha Lubricator panel did not come to the AMS. Alpha Lubricator solenoid…Anonymous · 8 mo0 rating0 commentsConsilium fire detection: five "Sensor fail" alarms from one zoneTroubleshootingFire & Safety · Consilium · Sensor fail, Communication errorFive "Sensor fail" alarms with "Communication error" came up suddenly, all from one zone (pump room). The failed points were on two loops: 3 smoke detectors on loop 2 and 2 manual call points on loop…Anonymous · 6 y0 rating0 commentsDual-fuel main engine: loud bangs and many alarms when changing over to gasTroubleshootingMain EngineThe main engine was started and changed over to gas. Loud bangs from the engine and many alarms.Anonymous · 7 mo0 rating0 commentsWeishaupt Monarch burner: random "Air combustion low" at startTroubleshootingBoiler · Weishaupt Monarch · Air combustion lowThe burner tripped only at boiler start, two or three times a day. The alarm changed: sometimes "Air combustion low", sometimes "Flame failure". It was random: no alarm for 10 hours, then up to five…Anonymous · 4 y0 rating0 commentsBoiler feed pumps air-lock every few hours and trip on low pressureTroubleshootingBoilerBoiler feed water pumps get air-locked. After venting they run for 2–3 hours (sometimes up to 2 days), then the same again. Both pump motors trip. Low pressure alarms on the boiler panel, mostly at…Anonymous · 1 y0 rating0 commentsConsilium CS4000: false fire alarm in cargo hold keeps coming backTroubleshootingFire & Safety · Consilium CS4000 · FIRE ALARM — FIRE ZONE 31 IS-DET 43Fire alarm from a cargo hold zone, but there was no fire. The Fault LED was also lit. After a reset the alarm came back the next morning and then would not reset. A full system restart did not help.…Anonymous · 6 mo0 rating0 commentsTMC Tamrotor screw compressor: "R:3137 RUN INHIBIT", "check pressure in pipe"TroubleshootingCompressed Air · TMC Tamrotor EMH 21-44 · R:3137 RUN INHIBITThe display showed 6.0 bar and "R:3137 RUN INHIBIT". The manual has only two alarms marked R. For them it says: "check pressure in pipe".Anonymous · 1 y0 rating0 commentsHyundai steering gear: pump stops 4 seconds after start from the bridgeTroubleshootingSteering Gear · HyundaiIn the evening the running steering gear pump stopped, and the standby pump started. Started from the bridge (autopilot), the pump motor ran for about 4 seconds and then stopped. No alarms on the…Anonymous · 3 y0 rating0 commentsMitsubishi deck crane will not start after a limit switch stopTroubleshootingDeck Machinery · MitsubishiThe crane limit switches were being tested during a class survey. A limit switch tripped and the crane stopped. After that the crane would not start at all. There were no alarms.Anonymous · 1 y0 rating0 comments220 V insulation alarm every morning, gone before you reach the switchboardTroubleshootingElectrical · Low insulation 220 VLow insulation alarm on the 220 V system early every morning, at breakfast time. By the time the engineer reached the switchboard, the reading was normal again. It started when a new cook joined the…Anonymous · 2 y0 rating0 commentsAlfa Laval S956: "Bowl speed low" alarm during separationTroubleshootingPurifier · Alfa Laval S956 · Bowl speed low"Bowl speed low" alarm about twice a day. The alarm came during separation, not during discharge. Often it came about 10 hours into the cycle. Between alarms the separator started, reached speed and…Anonymous · 5 y0 rating0 commentsHi Air Korea AC: compressor will not start, "FRESH ARM 1CRUN"TroubleshootingRefrigeration & HVAC · Hi Air Korea · FRESH ARM 1CRUNThe AC compressor did not start. No alarms were showing. When starting the compressor, only the controller on the AC control panel showed a new alarm: FRESH ARM 1CRUN. The manuals do not explain this…Anonymous · 4 mo0 rating0 commentsScrubber: "CEMS failure" alarm every 4 minutes, no alarm on the SICK analyserTroubleshootingOther · SICK CEMS · CEMS failureThe scrubber panel shows "CEMS failure" about every 4 minutes. Sometimes there is no alarm for about 20 minutes, then it comes back. The CEMS itself shows no new alarm. Its status goes to Stop and…Anonymous · 3 y0 rating0 commentsFuruno DS-60 speed log: wind, GPS SOG and COG not shown, no alarmTroubleshootingNavigation · Furuno DS-60 (DS-600 display)The speed log stopped showing wind. After the input wires were tightened, GPS SOG and GPS COG also disappeared (dashes on the display). No alarms on the panel or on the screen. All other bridge…Anonymous · 1 y0 rating0 commentsBallast valve remote control: half the valves stop responding, no alarmTroubleshootingBallast System · Utsuki valve remote control, Yokogawa FA-M3 PLCAbout half of the hydraulic ballast valves stopped responding, all at the same time. No reaction from the ballast console or from the local control panel. No alarms. The valves could still be moved…Anonymous · 6 y0 rating0 commentsEmergency generator breaker closes and opens again at once, no tripTroubleshootingElectrical · Schneider Masterpact NT06 H2, Micrologic 5.0 AThe emergency generator breaker would not stay closed on the emergency switchboard bus, in both auto and manual mode. On "close" the breaker clicked and closed. The green "closed" indication was on…Anonymous · 4 y0 rating0 commentsEmergency generator trips on blackout test, then will not close on the busTroubleshootingElectrical · Schneider Electric ComPacT NSX630Blackout test from the main switchboard: the supply to the emergency switchboard was switched off. The emergency generator started, closed onto the bus and took the load. After 5–10 minutes it…Anonymous · 6 mo0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y0 rating0 commentsGenerator con-rod seizes and holes the block: oil run far past interval (Ocean Navigator)IncidentAuxiliary Engine · Caterpillar 3516B · ER fire alarm, AE2 low LO pressure and oil filter plugged, blackoutAE2 on a coastal cruise ship (Caterpillar 3516B, 1,800 rpm) had run its LO for more than 5,000 h and its filter elements for 3,329 h. Both should be changed at 1,000 h (LO longer only under…Anonymous · 1 y0 rating0 commentsEngine room flooding from a corroded sea water pipe at the strainer (Oliver Hazard Perry)IncidentAuxiliary Engine · John Deere diesel generator · AC power fault alarm on fire alarm panel, blackoutSail training tall ship (128 ft), two Caterpillar C12 propulsion engines, two John Deere DGs (99 kW). Moored, one crewmember on board. Shore power breakers kept tripping, so the port DG ran…Anonymous · 7 mo0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y0 rating0 commentsStandard bearing shell on an undersize journal: con-rods break out (Ocean Guardian)IncidentAuxiliary Engine · Caterpillar 3516B · No alarm; loud bang, then smoke and fire in ERDiesel-electric offshore supply vessel, four Caterpillar 3516B main DGs (1,990 kW each). All four were overhauled by shore technicians in early 2022. On sea trials, DG3 had run about 4 h since…Anonymous · 3 y0 rating0 commentsDiesel oil bunkering: tank overflow through a taped vent, engine room fire (Stride)IncidentBoiler · MAN B&W 7S70MC Mk6 · Diesel oil seen dripping from upper ER; no tank high-level alarm recordedGeneral cargo ship alongside at LaPorte, Texas, taking 80 mt of LSMGO into the port and starboard double-bottom DO tanks. The C/E and 3/E ran the bunkering from the ECR, with both fill valves open.…Anonymous · 1 y