0 rating0 answersStern tube oil: high copper, cooler or pump wear suspectedTroubleshootingOpenPropulsion & ThrustersOur stern tube lube oil showed high copper (60-80 ppm); the cause is not confirmed, and I suspect wear in the oil cooler or circulating pumps rather than the bearing. Lab analysis of the stern tube…Anonymous · 4 y0 rating0 commentsCondition based maintenance on tankers and gas carriers: examplesKnowledgeMain Engine · MAN ES ME / MCCondition based maintenance (CBM) on tankers and gas carriers means working on equipment when its condition calls for it; these are the practical examples I use for the main engine, pumps and lube…Anonymous · 3 y0 rating0 commentsGenerator con-rod seizes and holes the block: oil run far past interval (Ocean Navigator)IncidentAuxiliary Engine · Caterpillar 3516B · ER fire alarm, AE2 low LO pressure and oil filter plugged, blackoutAE2 on a coastal cruise ship (Caterpillar 3516B, 1,800 rpm) had run its LO for more than 5,000 h and its filter elements for 3,329 h. Both should be changed at 1,000 h (LO longer only under…Anonymous · 1 y0 rating0 commentsThermal oil fire from a failing pump bearing, water mist did not work (Pride of Hull)IncidentPumps · Allweiler NTT 80-200 · ER fire alarm, zone "Oil treatment pumps"Ro-ro passenger ferry, outbound in the Humber. Thermal oil (Texatherm 32, winter set point 170 °C) carried heat from the economisers and a boiler. Circulation pump #1 was on duty. The fire panel…Anonymous · 4 y0 rating0 commentsUsing a new bunker before the lab report arrives: precautionsProcedureMain EngineWhen a ship has to change over to a new bunker before the lab report arrives, I treat the fuel as suspect and run with extra precautions on fuel treatment and engines until the result is known. The…Anonymous · 4 y0 rating0 commentsGenerator engine fails on non-OEM bearings run to OEM intervals (Kommandor Susan)IncidentAuxiliary Engine · Caterpillar 3516B-TA · ER fire alarm, blackoutDiesel-electric vessel on sea trials, just out of the lock at Leith with a pilot on board. DG1 and DG4 were on line. The C/E heard a change in engine note on one generator, then a loud bang. The fire…Anonymous · 6 mo0 rating0 commentsVolvo Penta D16: con-rods through crankcase from swapped big-end caps (Wight Sky)IncidentMain Engine · Volvo Penta D16 MH · ME2 low LO pressure shutdown; ME4 common alarmRo-ro ferry with four Volvo Penta D16 MH high-speed MEs; one or two drive each Voith Schneider unit through fluid couplings. Wight Sky had three catastrophic ME failures in 15 months. The 2017 one…Anonymous · 4 y0 rating0 commentsCPP hub oil loss from a cracked blade foot, not a blade seal (Maunalei)IncidentPropulsion & Thrusters · MAN Energy Solutions Mark 5 CPP; MAN B&W 7L70MC-C · Engineering alarm, CPP hub head tank found emptyContainership, MAN B&W 7L70MC-C two-stroke ME directly coupled to a 5-blade MAN Mark 5 CPP. On passage to Anchorage an alarm came up: CPP hub head tank empty. The crew reduced pitch and refilled the…Anonymous · 2 y0 rating0 commentsDiesel oil bunkering: tank overflow through a taped vent, engine room fire (Stride)IncidentBoiler · MAN B&W 7S70MC Mk6 · Diesel oil seen dripping from upper ER; no tank high-level alarm recordedGeneral cargo ship alongside at LaPorte, Texas, taking 80 mt of LSMGO into the port and starboard double-bottom DO tanks. The C/E and 3/E ran the bunkering from the ECR, with both fill valves open.…Anonymous · 1 y0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y0 rating0 commentsMAN 48/60: con-rod small end breaks after bad bush renewal (Finlandia Seaways)IncidentMain Engine · MAN 12V48/60 · Crankcase oil mist high, No. 6 main bearing temp highRo-ro at sea, single MAN 12V48/60 at 500 rpm, 110 662 running hours. The on-watch 3/E was in the purifier room when he heard loud metallic knocking. The bridge felt heavy vibration and saw pitch and…Anonymous · 5 y0 rating0 commentsStandard bearing shell on an undersize journal: con-rods break out (Ocean Guardian)IncidentAuxiliary Engine · Caterpillar 3516B · No alarm; loud bang, then smoke and fire in ERDiesel-electric offshore supply vessel, four Caterpillar 3516B main DGs (1,990 kW each). All four were overhauled by shore technicians in early 2022. On sea trials, DG3 had run about 4 h since…Anonymous · 3 y0 rating0 commentsEngine room fire: fuel backflow through an open return line (Scot Stuttgart)IncidentAuxiliary Engine · "" · ER fire alarm, thick white smoke in port ERChemical tanker with two engine rooms, alongside in San Juan discharging cargo. The port AE was under LOTO for turbocharger and aftercooler cleaning. The crew removed the aftercooler and the fuel…Anonymous · 2 mo0 rating0 commentsStern tube oil: EAL vs mineral oil, downsides beyond priceKnowledgePropulsion & ThrustersBeyond its higher price, EAL (bio, biodegradable) stern tube oil has two risks compared with mineral oil: some EAL oils hold a weaker oil film under heavy load, and EAL oil is harmed by water…Anonymous · 4 y0 rating0 commentsMAN B&W ME-C on VLSFO: which cylinder oil BN to useKnowledgeMain Engine · MAN B&W ME-CThere is no single right cylinder oil BN for MAN B&W ME-C two-stroke engines burning VLSFO (0.5 % sulphur): results depend on the engine and on how it is run. These are my notes from about three…Anonymous · 4 y0 rating0 answersMain engine scavenge drain tank level rising: piston crown O-ring leak suspectedTroubleshootingOpenMain EngineThe level in our main engine scavenge drain tank keeps going up, and I suspect system oil leaking into the scavenge space from the piston crown O-rings. The engine has a scavenge space, so it is most…Anonymous · 3 y0 rating0 commentsPods stuck at 90° after overspeed trip and a latched water-leak stop (Spirit of Discovery)IncidentPropulsion & Thrusters · Siemens SISHIp eSiPOD (SiPOD-M10) · Pod water leakage stop (WLS) sequence alarm, then propeller overspeedCruise ship with two Siemens eSiPOD pods (6,500 kW each, no rudder), crossing the Bay of Biscay in force 8–9 wind and 8–9 m waves. At 12:30 the port pod gave a WLS sequence alarm. Very soon after, it…Anonymous · 8 mo0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y0 rating0 commentsCO2 system: leaking cylinder valves release the whole bank (Eddystone, Red Eagle)IncidentFire & Safety · Schmöle K85-50 (Eddystone), DAB D10963 with D10964 actuator (Red Eagle) · CO2 release alarm, hissing in CO2 roomTwo UK ro-ro ships, same failure: nobody touched the CO2 release, but a bank emptied itself into the CO2 room. Eddystone was in the Southern Red Sea, ambient 32 °C. The CO2 release alarm sounded with…Anonymous · 8 y0 rating0 commentsAux boiler explosion: waxy MGO, then fan restart into a gassy furnace (Manhattan Bridge)IncidentBoiler · "" · Aux boiler emergency trip (Furnace flame-eye abnormal)A 13,900 TEU container ship was berthing at Felixstowe in winter. The auxiliary boiler (rotary cup burner) had been on MGO for three days for the ECA. It tripped four times between 17:30 and 19:51.…Anonymous · 8 y0 rating0 commentsAux engine room fire: slipped fuel pump coupling and exhaust leak (Finnmaster)IncidentAuxiliary Engine · Mitsubishi S12R · ER smoke alarm, then blackoutRo-ro leaving Hull with a pilot on board. AE1 had just been paralleled with AE2. Eight minutes after leaving the berth, smoke was detected in the aux engine room. Both AE2 exhaust temperature gauges…Anonymous · 1 y0 rating0 commentsMain engine EGR: deposits and wear depend mainly on fuel sulphurKnowledgeMain EngineOn a two-stroke main engine EGR (exhaust gas recirculation) system, fuel sulphur content is the main factor behind deposits in the air cooler and scavenge receiver and the amount of drain water and…Anonymous · 4 y0 rating0 commentsMain engine liners: how often to do external wear scanningKnowledgeMain EngineExternal electronic scanning of main engine cylinder liners by an outside company is worth doing; what is not settled is how often, at least yearly or about every 5 years backed by onboard…Anonymous · 4 y