0 rating0 commentsMain switchboard low insulation: find the fault by isolating loadsProcedureElectrical · Low insulationThis is how I find the cause of a low insulation alarm or low reading on the main switchboard (MSB): isolate all loads, then reconnect them one at a time while watching the insulation monitor. It…Anonymous · 4 y0 rating0 commentsDaihatsu 6DK generator: testing overspeed without a test buttonKnowledgeAuxiliary Engine · Anqing Daihatsu 6DK, Nanjing Chuzheng speed switchThe generator engine has a separate speed switch unit (Nanjing Chuzheng). It has no test button. The settings on its label: Setting Value Low speed 300 rpm Rated speed 720 rpm Overspeed 815 rpm…Anonymous · 6 y0 rating0 commentsCaterpillar 3408 generator will not start after blackoutTroubleshootingAuxiliary Engine · Caterpillar 3408The generator engine stopped and caused a blackout. Dirty fuel filters had let air into the fuel system. After the filters were changed, the engine cranked on the air starter but did not start.Anonymous · 3 y0 rating0 commentsHyundai lift works only in Manual or Inspection mode, not in Auto, no alarmTroubleshootingOther · Hyundai ElevatorIn heavy pitching, the ship slammed into a wave with strong vibration. The lift stopped at that moment. The car was brought down in Manual mode and the breaker was switched off. After switching on…Anonymous · 6 y0 rating0 commentsMooring winch with frequency converter: speed does not change with the joystickTroubleshootingDeck MachineryAn inverter-driven mooring winch stopped regulating speed from the joystick.Anonymous · 1 y0 rating0 commentsScania generator (DEC2): fires 2 or 3 times at start, then fuel is cut offTroubleshootingAuxiliary Engine · Scania, DEC2 digital engine controlThe diesel generator cranks and fires 2–3 times, as if trying to start. Then the fuel supply stops and the engine does not start. Fuel comes back only after the DEC2 digital engine control system…Anonymous · 6 y0 rating0 comments220 V insulation alarm every morning, gone before you reach the switchboardTroubleshootingElectrical · Low insulation 220 VLow insulation alarm on the 220 V system early every morning, at breakfast time. By the time the engineer reached the switchboard, the reading was normal again. It started when a new cook joined the…Anonymous · 2 y0 rating0 commentsEngine room flooding from a corroded sea water pipe at the strainer (Oliver Hazard Perry)IncidentAuxiliary Engine · John Deere diesel generator · AC power fault alarm on fire alarm panel, blackoutSail training tall ship (128 ft), two Caterpillar C12 propulsion engines, two John Deere DGs (99 kW). Moored, one crewmember on board. Shore power breakers kept tripping, so the port DG ran…Anonymous · 7 mo0 rating0 commentsACONIS AMS: diesel tanks show level, but volume does not changeTroubleshootingAutomation / PLC · Hyundai ACONISOn the ACONIS "Tank overview" page, the MGO (diesel oil) tanks showed the level correctly. The volume in m³ did not change when the level changed. Example: MGO storage tank (P) 10.64 m level showed…Anonymous · 5 y0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y0 rating0 commentsSauer air compressor keeps tripping, nothing found by handTroubleshootingCompressed Air · SauerThe air compressor tripped again and again for about 1.5 years.Anonymous · 2 y0 rating0 commentsGenerator engine fails on non-OEM bearings run to OEM intervals (Kommandor Susan)IncidentAuxiliary Engine · Caterpillar 3516B-TA · ER fire alarm, blackoutDiesel-electric vessel on sea trials, just out of the lock at Leith with a pilot on board. DG1 and DG4 were on line. The C/E heard a change in engine note on one generator, then a loud bang. The fire…Anonymous · 6 mo0 rating0 commentsAlfa Laval S956: "Bowl speed low" alarm during separationTroubleshootingPurifier · Alfa Laval S956 · Bowl speed low"Bowl speed low" alarm about twice a day. The alarm came during separation, not during discharge. Often it came about 10 hours into the cycle. Between alarms the separator started, reached speed and…Anonymous · 5 y0 rating0 commentsFuruno FAR-2837S radar: antenna motor thermal overload trips at switch-onTroubleshootingNavigation · Furuno FAR-2837S (S-band)S-band radar. The antenna is turned by an AC motor-gearbox, 3-phase 220 V, without brushes. The motor wires go straight into the motor body, there is no terminal box. As soon as the antenna is…Anonymous · 5 y0 rating0 commentsStandard bearing shell on an undersize journal: con-rods break out (Ocean Guardian)IncidentAuxiliary Engine · Caterpillar 3516B · No alarm; loud bang, then smoke and fire in ERDiesel-electric offshore supply vessel, four Caterpillar 3516B main DGs (1,990 kW each). All four were overhauled by shore technicians in early 2022. On sea trials, DG3 had run about 4 h since…Anonymous · 3 y0 rating0 commentsHi Air Korea AC: compressor will not start, "FRESH ARM 1CRUN"TroubleshootingRefrigeration & HVAC · Hi Air Korea · FRESH ARM 1CRUNThe AC compressor did not start. No alarms were showing. When starting the compressor, only the controller on the AC control panel showed a new alarm: FRESH ARM 1CRUN. The manuals do not explain this…Anonymous · 4 mo0 rating0 commentsKongsberg K-Chief 600: "ME SBW pot.meter" alarm after lever calibrationTroubleshootingMain Engine · Kongsberg K-Chief 600 · ME SBW POT.METERThe telegraph lever on the starboard bridge wing was calibrated. The calibration went normally. At the next manoeuvring the alarm "Lock in Last 'Speed Set Bridge'" came. It cleared. The alarm "ME SBW…Anonymous · 2 y0 rating0 commentsScrubber: "CEMS failure" alarm every 4 minutes, no alarm on the SICK analyserTroubleshootingOther · SICK CEMS · CEMS failureThe scrubber panel shows "CEMS failure" about every 4 minutes. Sometimes there is no alarm for about 20 minutes, then it comes back. The CEMS itself shows no new alarm. Its status goes to Stop and…Anonymous · 3 y0 rating0 commentsShaft torque meters with strain gauges: calibrate every 6 monthsKnowledgePropulsion & ThrustersI recommend calibrating shaft torque meters (shaft power meters) on the propulsion shafting every 6 months, at least those with strain gauges, because regular calibration stops the strain-gauge…Anonymous · 4 y0 rating0 commentsFuruno DS-60 speed log: wind, GPS SOG and COG not shown, no alarmTroubleshootingNavigation · Furuno DS-60 (DS-600 display)The speed log stopped showing wind. After the input wires were tightened, GPS SOG and GPS COG also disappeared (dashes on the display). No alarms on the panel or on the screen. All other bridge…Anonymous · 1 y0 rating0 commentsAlfa Laval 856 separator: "Bowl leak" alarm during the leakage testTroubleshootingPurifier · Alfa Laval 856 · Bowl leak"Bowl leak" alarm, but only during the test steps TI 66 or TI 71 (leakage test on fuel). Most often when displacement water was fed. During TI 66 the pressure fell from 1.6 to about 0.4 bar in about…Anonymous · 2 y0 rating0 commentsHFO to MGO changeover: cool slowly and watch viscosityProcedureMain EngineChanging the main engine and diesel generators from HFO to MGO is safe if fuel temperature falls slowly and viscosity stays between 2 cSt and 20 cSt. This is the general procedure I use; it follows…Anonymous · 3 y0 rating0 commentsMAN MC-C: no combustion in one unit, clogged ball valve at fuel pump inletTroubleshootingMain Engine · MAN B&W MC-C · Slowdown: exhaust gas temperature deviation, cylinder No.6Cylinder No.6 on our MAN MC-C stopped firing because the ball valve on the fuel oil inlet to its fuel pump was clogged. It took a long list of new parts before we found it. We reduced main engine…Anonymous · 4 y0 rating0 commentsYanmar generator: low LO pressure shutdown 5 minutes after startTroubleshootingAuxiliary Engine · YanmarAfter start, LO pressure was normal (4.8 bar), then slowly fell. After 5–6 minutes at most, the engine shut down on low LO pressure. The differential pressure indicator on the automatic LO filter…Anonymous · 4 y0 rating0 commentsAlfa Laval plate FWG: vacuum lost and will not come back past 60 %TroubleshootingFresh Water Generator · Alfa LavalFirst the salinity started to jump. One hour later the water level went out of the sight glass and the vacuum fell to 30 %. It all happened within a few hours. Before that, the vacuum built up in 30…Anonymous · 4 y0 rating0 commentsEmergency generator trips on blackout test, then will not close on the busTroubleshootingElectrical · Schneider Electric ComPacT NSX630Blackout test from the main switchboard: the supply to the emergency switchboard was switched off. The emergency generator started, closed onto the bus and took the load. After 5–10 minutes it…Anonymous · 6 mo0 rating0 commentsEmergency generator will not crank on batteries that test OKTroubleshootingAuxiliary EngineThe emergency generator did not start on the electric starter, from the remote panel or from the local panel on the engine. The engine turned over once or twice, then stopped cranking. The start…Anonymous · 4 y0 rating0 commentsAMS Totem Plus: ME Alpha Lubricator alarms go into inhibitTroubleshootingAutomation / PLC · Totem Plus IMACSAt sea, all ME Alpha Lubricator alarms on the AMS (about 6 channels) went into inhibit by themselves. Real alarms on the Alpha Lubricator panel did not come to the AMS. Alpha Lubricator solenoid…Anonymous · 8 mo0 rating0 commentsControl room console: lamp test, duty engineer call and phone horn all deadTroubleshootingElectricalSeveral functions of the engine control room console stopped at the same time: Lamp test did not work. Duty engineer call did not work. When the engine room telephone rang, the loud horn in the…Anonymous · 7 y0 rating0 commentsMain engine piston crowns burnt: long low-load running and bad injectorsTroubleshootingMain EngineBurn marks on our main engine piston crowns came, as far as we can tell, from long running at low load together with faulty fuel injectors. I found burn marks on the combustion side of the piston…Anonymous · 4 y
Load more30 of 79 shown