▲0 rating0 commentsNorimos 1000: "Signal syst. power F." alarm and all ventilation stopsTroubleshootingElectrical · Noris Norimos 1000 · SIGNAL SYST.POWER F.The alarm panel showed "SIGNAL SYST.POWER F." (signal system power failure). Right after it, all ventilation stopped. The ship was rolling.Anonymous · 7 y▲0 rating0 commentsTanker fixed gas sampling system: monthly and yearly checksKnowledgeFire & SafetyThe fixed gas sampling system on an oil tanker needs monthly crew checks (visual inspection, alarm test, zero and span calibration) plus, as good practice, a yearly health check by an authorized…Anonymous · 4 y▲0 rating0 commentsNabtesco governor: main engine will not go above 66 rpm, SCAVEN. LIMIT lamp onTroubleshootingMain Engine · Nabtesco governor control unit · M/E GOVERNOR SYSTEM ABNRThe main engine would not run faster than 66 rpm (Half Ahead). Scavenge air pressure was 0.2 bar. The auxiliary blowers were still running. On the governor control unit the SCAVEN. LIMIT lamp was on.…Anonymous · 3 y▲0 rating0 commentsHyundai steering gear: pump stops 4 seconds after start from the bridgeTroubleshootingSteering Gear · HyundaiIn the evening the running steering gear pump stopped, and the standby pump started. Started from the bridge (autopilot), the pump motor ran for about 4 seconds and then stopped. No alarms on the…Anonymous · 3 y▲0 rating0 commentsLNG dual-fuel ship: how the fuel gas supply system worksKnowledgeMain EngineThe fuel gas supply system (FGSS) on an LNG dual-fuel ship controls boil-off gas pressure in the LNG fuel tanks and turns LNG into gas for the engines and boilers; its design is set mainly by the…Anonymous · 3 y▲0 rating0 answersMain engine scavenge drain tank level rising: piston crown O-ring leak suspectedTroubleshootingOpenMain EngineThe level in our main engine scavenge drain tank keeps going up, and I suspect system oil leaking into the scavenge space from the piston crown O-rings. The engine has a scavenge space, so it is most…Anonymous · 3 y▲0 rating0 commentsCO2 system: leaking cylinder valves release the whole bank (Eddystone, Red Eagle)IncidentFire & Safety · Schmöle K85-50 (Eddystone), DAB D10963 with D10964 actuator (Red Eagle) · CO2 release alarm, hissing in CO2 roomTwo UK ro-ro ships, same failure: nobody touched the CO2 release, but a bank emptied itself into the CO2 room. Eddystone was in the Southern Red Sea, ambient 32 °C. The CO2 release alarm sounded with…Anonymous · 8 y▲0 rating0 commentsAC plant with two compressors: valves do not open on one compressorTroubleshootingRefrigeration & HVACAC plant with two compressors on one large AHU. With one compressor running alone, the refrigerant valves to the AHU cooling coil did not open. The controller gave no open command at all. The problem…Anonymous · 4 y▲0 rating0 commentsHFO to MGO changeover: cool slowly and watch viscosityProcedureMain EngineChanging the main engine and diesel generators from HFO to MGO is safe if fuel temperature falls slowly and viscosity stays between 2 cSt and 20 cSt. This is the general procedure I use; it follows…Anonymous · 3 y▲0 rating0 commentsMAN B&W ME: how cylinder prelubrication before start worksKnowledgeMain Engine · MAN B&W MEBackground The engine is a MAN B&W ME-type two-stroke main engine with Alpha cylinder lubricators. The ME hydraulic system pressure drives the lubricators. From the MOP (Main Operating Panel), the…Anonymous · 1 y▲0 rating0 commentsOceanGuard BWTS: "EUT Power Abnormal" 10 s after startTroubleshootingBallast System · OceanGuard · EUT Power Abnormal AlarmThe BWTS worked normally 3 days before. Now, about 10 seconds after start, the alarm "EUT Power Abnormal Alarm" came up and the system stopped. The EUT power unit got its supply: LEDs on all modules…Anonymous · 3 y▲0 rating0 commentsBallast valve remote control: half the valves stop responding, no alarmTroubleshootingBallast System · Utsuki valve remote control, Yokogawa FA-M3 PLCAbout half of the hydraulic ballast valves stopped responding, all at the same time. No reaction from the ballast console or from the local control panel. No alarms. The valves could still be moved…Anonymous · 6 y▲0 rating0 commentsConsilium CS4000: new manual call point gives "No answer"TroubleshootingFire & Safety · Consilium CS4000 · No answerAn old manual call point (P/N 11305) was replaced with the new type MCP-A, P/N 5200030-01A. The system did not find the new unit: alarm "No answer" for its address, although the address was set…Anonymous · 1 y▲0 rating0 commentsBWTS in muddy ports: filters clog, how to ballast and when to bypassProcedureBallast SystemBallasting in very muddy water clogs and can damage the BWTS filter; this note covers how I ballast in those ports and when a bypass is allowed. In my experience this happens mostly in Chinese ports.…Anonymous · 4 y▲0 rating0 commentsAux engine room fire: slipped fuel pump coupling and exhaust leak (Finnmaster)IncidentAuxiliary Engine · Mitsubishi S12R · ER smoke alarm, then blackoutRo-ro leaving Hull with a pilot on board. AE1 had just been paralleled with AE2. Eight minutes after leaving the berth, smoke was detected in the aux engine room. Both AE2 exhaust temperature gauges…Anonymous · 1 y▲0 rating0 commentsMAN ME-C: running with one HPS pump in fail modeKnowledgeMain Engine · MAN Energy Solutions ME-CWith one of three HPS pumps in "fail", an ME-C main engine can usually keep full function if the fault is only electronic or in the cables; a mechanical fault is a different case. These are my notes…Anonymous · 3 y▲0 rating0 commentsConsilium fire detection: five "Sensor fail" alarms from one zoneTroubleshootingFire & Safety · Consilium · Sensor fail, Communication errorFive "Sensor fail" alarms with "Communication error" came up suddenly, all from one zone (pump room). The failed points were on two loops: 3 smoke detectors on loop 2 and 2 manual call points on loop…Anonymous · 6 y▲0 rating0 commentsEngine room fire: fuel backflow through an open return line (Scot Stuttgart)IncidentAuxiliary Engine · "" · ER fire alarm, thick white smoke in port ERChemical tanker with two engine rooms, alongside in San Juan discharging cargo. The port AE was under LOTO for turbocharger and aftercooler cleaning. The crew removed the aftercooler and the fuel…Anonymous · 2 mo▲0 rating0 commentsDiesel oil bunkering: tank overflow through a taped vent, engine room fire (Stride)IncidentBoiler · MAN B&W 7S70MC Mk6 · Diesel oil seen dripping from upper ER; no tank high-level alarm recordedGeneral cargo ship alongside at LaPorte, Texas, taking 80 mt of LSMGO into the port and starboard double-bottom DO tanks. The C/E and 3/E ran the bunkering from the ECR, with both fill valves open.…Anonymous · 1 y▲0 rating0 commentsInert gas oxygen analyzers keep failing: a care routine that worksProcedureFire & SafetyInert gas (IG) oxygen analyzers that fail again and again are, in my view, usually handled badly or not maintained correctly; this is the care routine I use to prevent it. Repeated failures with…Anonymous · 4 y▲0 rating0 commentsOpen-loop SOx scrubber: common problems with pipes, sensors and pumpsKnowledgeOtherThese are the usual trouble spots on SOx scrubbers, from my experience and from one other engineer. We both talk about open-loop systems. I do not name a ship, engine or scrubber maker here. This is…Anonymous · 4 y▲0 rating0 commentsCondition based maintenance on tankers and gas carriers: examplesKnowledgeMain Engine · MAN ES ME / MCCondition based maintenance (CBM) on tankers and gas carriers means working on equipment when its condition calls for it; these are the practical examples I use for the main engine, pumps and lube…Anonymous · 3 y▲0 rating0 commentsBWTS valve with Siemens SIPART PS2 positioner: alarm A29, valve limit switchTroubleshootingBallast System · Siemens SIPART PS2 6DR5020-0NG30-0AB0 · A29The ballast water treatment system gave alarm A29: limit switch fault on a valve. The limit switch is inside the valve positioner, wired to terminals 41–42.Anonymous · 6 y▲0 rating0 commentsAlfa Laval PA605 will not start after emergency stop is releasedTroubleshootingPurifier · Alfa Laval PA605 · Emergency button pressThe emergency stop button was pressed. After the button was released, the pump and the separator would not start. The alarm "Emergency button press" stayed on.Anonymous · 2 y▲0 rating0 commentsScania generator (DEC2): fires 2 or 3 times at start, then fuel is cut offTroubleshootingAuxiliary Engine · Scania, DEC2 digital engine controlThe diesel generator cranks and fires 2–3 times, as if trying to start. Then the fuel supply stops and the engine does not start. Fuel comes back only after the DEC2 digital engine control system…Anonymous · 6 y▲0 rating0 comments220 V insulation alarm every morning, gone before you reach the switchboardTroubleshootingElectrical · Low insulation 220 VLow insulation alarm on the 220 V system early every morning, at breakfast time. By the time the engineer reached the switchboard, the reading was normal again. It started when a new cook joined the…Anonymous · 2 y▲0 rating0 commentsFatal engine room fire after opening a pressurised fuel filter (Moritz Schulte)IncidentAuxiliary Engine · MAN B&W L23/30H · ER fire alarmLPG carrier discharging alongside in Antwerp. AE2 and AE3 were running and AE1 was on standby. After the morning toolbox talk the newly promoted 3/E asked the 2/E if he could clean the AE1 fuel…Anonymous · 3 y▲0 rating0 commentsAlpha Lubricator: "Feedback failure" slowdown comes and goesTroubleshootingMain Engine · MAN B&W Alpha Lubricator · Feedback failureMain engine slowdown from the Alpha Lubricator system, alarm "Feedback failure". The alarm came for 5 to 60 seconds and then cleared by itself. In the menu it showed as Alarm 3. By the manual, Alarm…Anonymous · 4 y▲0 rating0 commentsDoosan emergency generator: testing overspeed without a test buttonKnowledgeAuxiliary Engine · Doosan AD136TS, KMC ECMS-850EH · OverspeedThe set: Doosan AD136TS engine (1800 rpm, 125 kW) with a KMC ECMS-850EH engine control and monitoring system. The wiring diagram in the manual shows a GAC ESD5550 speed control unit with "TEST…Anonymous · 3 y▲0 rating0 commentsSea water cooling pump: no pressure and low current after overhaulTroubleshootingPumpsThe cooling sea water pump had just been overhauled, and a new motor was fitted: 25.3 kW, 39.5 A, 440 V delta, 1800 rpm. After start the pump gave no pressure. Motor current rose from 17 A to 24 A…Anonymous · 7 y