0 rating0 commentsSwitchboard earth lamps do not light, only one of three on lamp testTroubleshootingElectricalThe insulation resistance monitor (IRM) worked normally. The earth lamps did not light. With the test button pressed, only one of the three lamps lit.Anonymous · 3 mo0 rating0 commentsHi Air Korea AC: compressor will not start, "FRESH ARM 1CRUN"TroubleshootingRefrigeration & HVAC · Hi Air Korea · FRESH ARM 1CRUNThe AC compressor did not start. No alarms were showing. When starting the compressor, only the controller on the AC control panel showed a new alarm: FRESH ARM 1CRUN. The manuals do not explain this…Anonymous · 4 mo1 rating0 commentsConsilium CS4000: "IOM70 Synchronisation signal" faultTroubleshootingFire & Safety · Consilium CS4000 · CENTRAL 1 IOM70 51 SYNCHRONISATION SIGNALFault alarm on the water mist main panel: "(212) CENTRAL 1 IOM70 51 SYNCHRONISATION SIGNAL", with "PUMP CONTROL BOX - UNIT FAULT INPUTS". On the I/O M70 module: PS LED flashing yellow, COM LED green.…Anonymous · 6 mo0 rating0 commentsConsilium CS4000: false fire alarm in cargo hold keeps coming backTroubleshootingFire & Safety · Consilium CS4000 · FIRE ALARM — FIRE ZONE 31 IS-DET 43Fire alarm from a cargo hold zone, but there was no fire. The Fault LED was also lit. After a reset the alarm came back the next morning and then would not reset. A full system restart did not help.…Anonymous · 6 mo0 rating0 commentsEmergency generator trips on blackout test, then will not close on the busTroubleshootingElectrical · Schneider Electric ComPacT NSX630Blackout test from the main switchboard: the supply to the emergency switchboard was switched off. The emergency generator started, closed onto the bus and took the load. After 5–10 minutes it…Anonymous · 6 mo1 rating0 commentsHyundai HV switchboard: generator VCB tripped, no reset buttonTroubleshootingElectrical · Hyundai HIMAP-BCThe generator engine shut down on lube oil. HIMAP showed reverse power, and the generator VCB (6600 V) tripped. The breaker could not be reset at the breaker. There is no reset button and no handle…Anonymous · 7 mo0 rating0 commentsDual-fuel main engine: loud bangs and many alarms when changing over to gasTroubleshootingMain EngineThe main engine was started and changed over to gas. Loud bangs from the engine and many alarms.Anonymous · 7 mo0 rating0 commentsAMS Totem Plus: ME Alpha Lubricator alarms go into inhibitTroubleshootingAutomation / PLC · Totem Plus IMACSAt sea, all ME Alpha Lubricator alarms on the AMS (about 6 channels) went into inhibit by themselves. Real alarms on the Alpha Lubricator panel did not come to the AMS. Alpha Lubricator solenoid…Anonymous · 8 mo0 rating0 commentsMAN ME-C: "Low stroke" slowdown, exhaust valve position signal drops outTroubleshootingMain Engine · MAN B&W ME-C · Low strokeMain engine slowdown with "Low stroke" alarm on one cylinder. On the MOP, the exhaust valve position signal from the inductive sensor dropped out about every 3 seconds. Each time, fuel injection to…Anonymous · 8 mo0 rating0 commentsAlfa Laval plate FWG: high brine temperature (60 °C) and low outputTroubleshootingFresh Water Generator · Alfa Laval (plate type)Low fresh water output and brine temperature up to 60 °C. Cleaning the plates did not help. Vacuum and heating water were normal. Readings, the same before and after cleaning: Reading Value Heating…Anonymous · 10 mo0 rating0 commentsAutronica: loop fault on Ex detector stays after barrier replacementTroubleshootingFire & Safety · Autronica, BZB 500 interface unit · LOOP FAULTS: LOOP 01 / POINT FAULTS: 10106 SD(EXI)Open-circuit fault on the paint store detector line. The panel showed "LOOP FAULTS 1 LOOP 01" and "POINT FAULTS 1 10106 SD(EXI)". The system did not see the detector.Anonymous · 1 y0 rating0 commentsCummins NTA855 emergency generator: speed hunts ±30 rpm after a cold startTroubleshootingAuxiliary Engine · Cummins NTA855-D(M)On the first cold start, speed hunted by about ±30 rpm at 1800 rpm (frequency by about 0.5 Hz). After a restart (sometimes the 2nd or 3rd) it ran smoothly, and further starts were fine. A few hours…Anonymous · 1 y0 rating0 commentsConsilium CS4000: new manual call point gives "No answer"TroubleshootingFire & Safety · Consilium CS4000 · No answerAn old manual call point (P/N 11305) was replaced with the new type MCP-A, P/N 5200030-01A. The system did not find the new unit: alarm "No answer" for its address, although the address was set…Anonymous · 1 y0 rating0 commentsAlfa Laval boiler: both HMI panels show "Comm err station 0"TroubleshootingBoiler · Alfa Laval, Beijer HMI · Controller1_TCP: Comm err station 0After the boiler control power was switched off and on, neither HMI panel started working: not the local panel, not the one in the ECR. Both panels showed only the start screen with "Controller1TCP:…Anonymous · 1 y0 rating0 commentsFuruno DS-60 speed log: wind, GPS SOG and COG not shown, no alarmTroubleshootingNavigation · Furuno DS-60 (DS-600 display)The speed log stopped showing wind. After the input wires were tightened, GPS SOG and GPS COG also disappeared (dashes on the display). No alarms on the panel or on the screen. All other bridge…Anonymous · 1 y0 rating0 commentsBoiler feed pumps air-lock every few hours and trip on low pressureTroubleshootingBoilerBoiler feed water pumps get air-locked. After venting they run for 2–3 hours (sometimes up to 2 days), then the same again. Both pump motors trip. Low pressure alarms on the boiler panel, mostly at…Anonymous · 1 y0 rating0 commentsMitsubishi deck crane will not start after a limit switch stopTroubleshootingDeck Machinery · MitsubishiThe crane limit switches were being tested during a class survey. A limit switch tripped and the crane stopped. After that the crane would not start at all. There were no alarms.Anonymous · 1 y0 rating0 commentsGenerator will not come off the bus at stop: "Stop failure", reverse powerTroubleshootingElectrical · Stop failureThe undervoltage (UV) coil of a generator air circuit breaker (ACB) was burnt. To keep the breaker usable, the UV coil plunger was held in with its mechanical lock. The generator synchronised and…Anonymous · 1 y0 rating0 commentsAalborg thermal oil boiler: no fuel from the nozzle at ignitionTroubleshootingBoiler · Aalborg, LAL burner controlAfter a safety alarm test the boiler stopped and did not start again. The coil of the recirculation (return) solenoid valve had burnt. It had run hot for a long time: it looked melted and its wiring…Anonymous · 1 y0 rating0 commentsHoppe valve remote control shows open and closed at the same timeTroubleshootingAutomation / PLC · Hoppe HOMIPOn the HOMIP valve remote control, one electro-hydraulic valve showed "open" and "closed" at the same time. Locally the valve worked correctly and moved fully open and closed.Anonymous · 1 y0 rating0 commentsMain engine: gas bubbles in the fuel system, fuel pressure jumpingTroubleshootingMain EngineAir (gas) bubbles in the main engine fuel oil system. Small bubbles stayed all the time. Fuel pressure was jumping.Anonymous · 1 y0 rating0 commentsEngine room fan trips its breaker when the soft starter switches to bypassTroubleshootingRefrigeration & HVAC · Schneider Altistart 48 (ATS48)The main engine room supply fan is reversible and is started by a soft starter with a bypass contactor. The soft starter ran the fan up normally in about 15 seconds. At the moment the bypass…Anonymous · 1 y0 rating0 commentsSAM Electronics ME HT cooling: temperature swings 8 °C in autoTroubleshootingMain Engine · SAM ElectronicsThe ME HT cooling water temperature controller (HT cooler valve) could not hold the set point in auto. The temperature went up and down by about 8 °C. Because of this, the system was run in manual…Anonymous · 1 y0 rating0 commentsTMC Tamrotor screw compressor: "R:3137 RUN INHIBIT", "check pressure in pipe"TroubleshootingCompressed Air · TMC Tamrotor EMH 21-44 · R:3137 RUN INHIBITThe display showed 6.0 bar and "R:3137 RUN INHIBIT". The manual has only two alarms marked R. For them it says: "check pressure in pipe".Anonymous · 1 y0 rating0 commentsNewins IC5000 cold room indicator shows LLLL after resetTroubleshootingRefrigeration & HVAC · Newins IC5000The cold chamber remote temperature indicator read 6 °C different from the real temperature. The settings were reset as the manual says: hold two keys while switching the power on. After the reset,…Anonymous · 1 y0 rating0 commentsMooring winch with frequency converter: speed does not change with the joystickTroubleshootingDeck MachineryAn inverter-driven mooring winch stopped regulating speed from the joystick.Anonymous · 1 y0 rating0 commentsAC compressor loses oil pressure at start after overhaul with new partsTroubleshootingRefrigeration & HVAC · Low oil pressureThe air-conditioning compressors were overhauled with a new spare parts kit. After the overhaul, oil pressure dropped at every start.Anonymous · 1 y0 rating0 commentsBock compressor (AC plant): oil solenoid valve coils overheat and meltTroubleshootingRefrigeration & HVAC · BockAC plant with a Bock compressor. The coil of the oil solenoid valve (220 V, 60 Hz, 10 W) burnt. A new coil heated up very fast and melted. The next coils melted too. Before this, everything had…Anonymous · 1 y0 rating0 commentsAlfa Laval separator: alarm A85 (MT60 fault), water content shows only dashesTroubleshootingPurifier · Alfa Laval · A85 (MT60 fault)Separator with a water content transducer. The transducer had problems for about two weeks. The transducer board was replaced with a new one. After that, alarm A85 (MT60 fault) came up. The old board…Anonymous · 2 y0 rating0 commentsWestfalia OSD 60-91: bowl does not close, ejection monitoring alarmTroubleshootingPurifier · Westfalia OSD 60-91 · Ejection monitoringTwo main engine LO separators stopped one after the other on the ejection monitoring alarm. On both, the bowl did not close at all. No discharge either, not even a small one. No. 1 stopped 1,000…Anonymous · 2 y
Load more30 of 114 shown