Search

Cases

0 rating0 commentsMain engine: gas bubbles in the fuel system, fuel pressure jumpingTroubleshootingMain EngineAir (gas) bubbles in the main engine fuel oil system. Small bubbles stayed all the time. Fuel pressure was jumping.Anonymous · 1 y0 rating0 commentsMain engine: fuel pressure slowdowns, deaeration chamber full of gasTroubleshootingMain EngineRepeated main engine slowdowns on fuel oil pressure. It took about 4 days to find the cause. The deaeration chamber was "boiling" with gas. The gas came into the fuel system through the return line…Anonymous · 5 y0 rating0 commentsMAN MC-C: no combustion in one unit, clogged ball valve at fuel pump inletTroubleshootingMain Engine · MAN B&W MC-C · Slowdown: exhaust gas temperature deviation, cylinder No.6Cylinder No.6 on our MAN MC-C stopped firing because the ball valve on the fuel oil inlet to its fuel pump was clogged. It took a long list of new parts before we found it. We reduced main engine…Anonymous · 4 y0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y0 rating0 commentsAalborg thermal oil boiler: no fuel from the nozzle at ignitionTroubleshootingBoiler · Aalborg, LAL burner controlAfter a safety alarm test the boiler stopped and did not start again. The coil of the recirculation (return) solenoid valve had burnt. It had run hot for a long time: it looked melted and its wiring…Anonymous · 1 y0 rating0 commentsIMO fuel supply pump gives only 5 bar on diesel oilTroubleshootingPumps · IMOThe fuel supply pumps (IMO screw pumps) gave only about 5 bar when running on diesel oil. The ship rarely ran on diesel, so the fault went unnoticed for a long time. It took three months to find.Anonymous · 2 y0 rating0 commentsDual-fuel main engine: loud bangs and many alarms when changing over to gasTroubleshootingMain EngineThe main engine was started and changed over to gas. Loud bangs from the engine and many alarms.Anonymous · 7 mo0 rating0 commentsEngine room fire: fuel backflow through an open return line (Scot Stuttgart)IncidentAuxiliary Engine · "" · ER fire alarm, thick white smoke in port ERChemical tanker with two engine rooms, alongside in San Juan discharging cargo. The port AE was under LOTO for turbocharger and aftercooler cleaning. The crew removed the aftercooler and the fuel…Anonymous · 2 mo0 rating0 commentsME exhaust valve spindle burn-through: common causesKnowledgeMain EngineExhaust valve spindle burn-through on a two-stroke main engine usually comes from one of a short list of factors, each of which makes the spindle burn away faster and shortens the time between…Anonymous · 4 y0 rating0 commentsHFO to MGO changeover: cool slowly and watch viscosityProcedureMain EngineChanging the main engine and diesel generators from HFO to MGO is safe if fuel temperature falls slowly and viscosity stays between 2 cSt and 20 cSt. This is the general procedure I use; it follows…Anonymous · 3 y0 rating0 commentsAlfa Laval SA 836: oil comes out of the bowl water feed pipeTroubleshootingPurifier · Alfa Laval SA 836 · Oil leaking from bowlAt start, after some time, heavy fuel oil came out of the pipe that feeds water into the bowl. No pressure on PT4 and PT5 (oil and water outlets). Alarm "Oil leaking from bowl".Anonymous · 6 y0 rating0 commentsSiemens LOGO! fuel changeover: program loaded but does not runTroubleshootingAutomation / PLC · Siemens LOGO! 230RC with DM8 230R and AM2 expansion modules · Control failThe automatic HFO/MDO changeover (valves and fuel heating) is controlled by a Siemens LOGO! 230RC with expansion modules. A "Control fail" alarm came up on the fuel page of the control PC. Expansion…Anonymous · 3 y0 rating0 commentsAlfa Laval 856 separator: "Bowl leak" alarm during the leakage testTroubleshootingPurifier · Alfa Laval 856 · Bowl leak"Bowl leak" alarm, but only during the test steps TI 66 or TI 71 (leakage test on fuel). Most often when displacement water was fed. During TI 66 the pressure fell from 1.6 to about 0.4 bar in about…Anonymous · 2 y0 rating0 commentsWeishaupt Monarch burner sprays fuel as soon as the fan startsTroubleshootingBoiler · Weishaupt MonarchFuel sprayed from the nozzle as soon as the burner fan motor started, during pre-purge. It should spray only after purge, when the air damper closes, together with ignition. The burner started and…Anonymous · 6 y0 rating0 commentsBoiler burner smokes, and more air makes it worseTroubleshootingBoilerThe boiler was smoking. Adding more combustion air made the smoke worse. The burner is set to run on the first stage only. The second stage was switched off on the panel.Anonymous · 3 y0 rating0 commentsCummins NTA855 emergency generator: speed hunts ±30 rpm after a cold startTroubleshootingAuxiliary Engine · Cummins NTA855-D(M)On the first cold start, speed hunted by about ±30 rpm at 1800 rpm (frequency by about 0.5 Hz). After a restart (sometimes the 2nd or 3rd) it ran smoothly, and further starts were fine. A few hours…Anonymous · 1 y0 rating0 commentsMAN 6S50ME-C: unit loses compression 10 minutes after overhaulTroubleshootingMain Engine · MAN B&W 6S50ME-CUnit 1 of the main engine was overhauled. Tests in port were normal. About 10 minutes after leaving port, the unit started knocking and lost compression. After a restart the unit worked again, but…Anonymous · 4 y0 rating0 commentsMAN B&W two-stroke: limits for judging engine performanceKnowledgeMain Engine · MAN B&W MC/MC-C, ME/ME-C/ME-BThis is my checklist of practical limits for judging the performance of MAN B&W two-stroke main engines, both mechanical (MC/MC-C) and electronic (ME/ME-C/ME-B). I don't have the source of the limits…Anonymous · 3 y0 rating0 commentsAux engine room fire: slipped fuel pump coupling and exhaust leak (Finnmaster)IncidentAuxiliary Engine · Mitsubishi S12R · ER smoke alarm, then blackoutRo-ro leaving Hull with a pilot on board. AE1 had just been paralleled with AE2. Eight minutes after leaving the berth, smoke was detected in the aux engine room. Both AE2 exhaust temperature gauges…Anonymous · 1 y0 rating0 commentsBoll & Kirch filter turns back to the dirty chamber at flushingTroubleshootingOther · Boll & Kirch 6.72, BK 2200 controllerAt backflushing: The solenoid worked and the filter turned to the clean chamber. The solenoid switched off, air was cut, and the filter turned back to the dirty chamber. This happened twice in a row.…Anonymous · 5 y0 rating0 commentsDiesel oil bunkering: tank overflow through a taped vent, engine room fire (Stride)IncidentBoiler · MAN B&W 7S70MC Mk6 · Diesel oil seen dripping from upper ER; no tank high-level alarm recordedGeneral cargo ship alongside at LaPorte, Texas, taking 80 mt of LSMGO into the port and starboard double-bottom DO tanks. The C/E and 3/E ran the bunkering from the ECR, with both fill valves open.…Anonymous · 1 y0 rating0 commentsAux boiler explosion: waxy MGO, then fan restart into a gassy furnace (Manhattan Bridge)IncidentBoiler · "" · Aux boiler emergency trip (Furnace flame-eye abnormal)A 13,900 TEU container ship was berthing at Felixstowe in winter. The auxiliary boiler (rotary cup burner) had been on MGO for three days for the ECA. It tripped four times between 17:30 and 19:51.…Anonymous · 8 y0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y0 rating0 commentsOil tanker aux boilers: tests before cargo dischargeProcedureBoilerBefore cargo discharge on an oil tanker, I test the auxiliary boilers so they keep working through the discharge: boiler water, controls, and the pumps under load. This applies to any boiler maker…Anonymous · 4 y0 rating0 commentsBunker fuel quality: ISO 8217 fuel can still cause engine problemsKnowledgeMain EngineThese are my general notes about bunker fuel quality. They do not describe a real fault on a ship. I give no engine maker, no readings and no test results. I wrote them in two parts. Main point…Anonymous · 2 y0 rating0 commentsFatal engine room fire after opening a pressurised fuel filter (Moritz Schulte)IncidentAuxiliary Engine · MAN B&W L23/30H · ER fire alarmLPG carrier discharging alongside in Antwerp. AE2 and AE3 were running and AE1 was on standby. After the morning toolbox talk the newly promoted 3/E asked the 2/E if he could clean the AE1 fuel…Anonymous · 3 y0 rating0 commentsMain engine turbocharger surging: causes and preventionKnowledgeTurbochargerI wanted to know what turbocharger surging is and how to prevent it. One other engineer answered, and I accepted that answer. This is general guidance. It is not a real fault case. No engine or…Anonymous · 4 y0 rating0 commentsMAN ME-C: "Low stroke" slowdown, exhaust valve position signal drops outTroubleshootingMain Engine · MAN B&W ME-C · Low strokeMain engine slowdown with "Low stroke" alarm on one cylinder. On the MOP, the exhaust valve position signal from the inductive sensor dropped out about every 3 seconds. Each time, fuel injection to…Anonymous · 8 mo0 rating0 commentsTwo-stroke load diagram: why the same mep is overload at low rpmKnowledgeMain Engine · MAN B&WOn a MAN B&W two-stroke load diagram, the same mep that is fine at high RPM counts as overload at low RPM because the torque limit is set mainly by the thermal load of engine components, with weak…Anonymous · 3 y0 rating0 commentsHow to take one cylinder out of service on MAN ME-CProcedureMain Engine · MAN ES ME-CTo take one cylinder unit out of operation on an ME-C (electronically controlled 2-stroke) main engine, I set the Chief Index limit for that cylinder to 0 on the MOP. This is an outline only. The…Anonymous · 4 y
Load more30 of 33 shown