▲0 rating0 commentsAC compressor loses oil pressure at start after overhaul with new partsTroubleshootingRefrigeration & HVAC · Low oil pressureThe air-conditioning compressors were overhauled with a new spare parts kit. After the overhaul, oil pressure dropped at every start.Anonymous · 1 y▲0 rating0 commentsYanmar generator: low LO pressure shutdown 5 minutes after startTroubleshootingAuxiliary Engine · YanmarAfter start, LO pressure was normal (4.8 bar), then slowly fell. After 5–6 minutes at most, the engine shut down on low LO pressure. The differential pressure indicator on the automatic LO filter…Anonymous · 4 y▲0 rating0 commentsAlfa Laval SA805 lube oil separator: bowl opens by itself after about 10 hoursTroubleshootingPurifier · Alfa Laval SA805 · Low back pressureThe separator ran for about 10 hours, then the bowl opened by itself. The closing water went to the drain, and nothing held the bowl closed. Alarm: "Low back pressure". The other two separators…Anonymous · 4 y▲0 rating0 commentsGenerator con-rod seizes and holes the block: oil run far past interval (Ocean Navigator)IncidentAuxiliary Engine · Caterpillar 3516B · ER fire alarm, AE2 low LO pressure and oil filter plugged, blackoutAE2 on a coastal cruise ship (Caterpillar 3516B, 1,800 rpm) had run its LO for more than 5,000 h and its filter elements for 3,329 h. Both should be changed at 1,000 h (LO longer only under…Anonymous · 1 y▲0 rating0 commentsStern tube air seal: risk of losing air supply at deep draftKnowledgePropulsion & ThrustersLoss of the air supply to a stern tube air seal is a serious condition, because at deep draft the oil head alone may not hold back seawater and seawater may enter the stern tube. Loss of air supply…Anonymous · 3 y▲0 rating0 commentsSchaller Visatron VN215 oil mist detector: error E 012 a week after serviceTroubleshootingMain Engine · Schaller Visatron VN215/93 · E 012The oil mist detector was fully serviced: optics cleaned, filters changed, negative pressure set as per the manual. One week later it showed error E 012.Anonymous · 2 y▲0 rating0 commentsVolvo Penta D16: con-rods through crankcase from swapped big-end caps (Wight Sky)IncidentMain Engine · Volvo Penta D16 MH · ME2 low LO pressure shutdown; ME4 common alarmRo-ro ferry with four Volvo Penta D16 MH high-speed MEs; one or two drive each Voith Schneider unit through fluid couplings. Wight Sky had three catastrophic ME failures in 15 months. The 2017 one…Anonymous · 4 y▲0 rating0 commentsMAN B&W ME: how cylinder prelubrication before start worksKnowledgeMain Engine · MAN B&W MEBackground The engine is a MAN B&W ME-type two-stroke main engine with Alpha cylinder lubricators. The ME hydraulic system pressure drives the lubricators. From the MOP (Main Operating Panel), the…Anonymous · 1 y▲0 rating0 commentsOWS 15 ppm monitor cannot detect a blocked sampling lineKnowledgeOWS & Bilge · JOWA; Bilgemon488 15 ppm monitorA 15 ppm bilge alarm without a low sample flow switch cannot tell when its sampling line is closed or blocked, so the OWS can keep discharging overboard. A poorly placed sampling point can also make…Anonymous · 3 y▲0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y▲0 rating0 commentsAlfa Laval SA 836: oil comes out of the bowl water feed pipeTroubleshootingPurifier · Alfa Laval SA 836 · Oil leaking from bowlAt start, after some time, heavy fuel oil came out of the pipe that feeds water into the bowl. No pressure on PT4 and PT5 (oil and water outlets). Alarm "Oil leaking from bowl".Anonymous · 6 y▲0 rating0 commentsAalborg thermal oil boiler: no fuel from the nozzle at ignitionTroubleshootingBoiler · Aalborg, LAL burner controlAfter a safety alarm test the boiler stopped and did not start again. The coil of the recirculation (return) solenoid valve had burnt. It had run hot for a long time: it looked melted and its wiring…Anonymous · 1 y▲0 rating0 commentsIMO fuel supply pump gives only 5 bar on diesel oilTroubleshootingPumps · IMOThe fuel supply pumps (IMO screw pumps) gave only about 5 bar when running on diesel oil. The ship rarely ran on diesel, so the fault went unnoticed for a long time. It took three months to find.Anonymous · 2 y▲0 rating0 commentsCPP hub oil loss from a cracked blade foot, not a blade seal (Maunalei)IncidentPropulsion & Thrusters · MAN Energy Solutions Mark 5 CPP; MAN B&W 7L70MC-C · Engineering alarm, CPP hub head tank found emptyContainership, MAN B&W 7L70MC-C two-stroke ME directly coupled to a 5-blade MAN Mark 5 CPP. On passage to Anchorage an alarm came up: CPP hub head tank empty. The crew reduced pitch and refilled the…Anonymous · 2 y▲0 rating0 commentsMain engine: fuel pressure slowdowns, deaeration chamber full of gasTroubleshootingMain EngineRepeated main engine slowdowns on fuel oil pressure. It took about 4 days to find the cause. The deaeration chamber was "boiling" with gas. The gas came into the fuel system through the return line…Anonymous · 5 y▲0 rating0 commentsMain engine: gas bubbles in the fuel system, fuel pressure jumpingTroubleshootingMain EngineAir (gas) bubbles in the main engine fuel oil system. Small bubbles stayed all the time. Fuel pressure was jumping.Anonymous · 1 y▲0 rating0 commentsScania generator (DEC2): fires 2 or 3 times at start, then fuel is cut offTroubleshootingAuxiliary Engine · Scania, DEC2 digital engine controlThe diesel generator cranks and fires 2–3 times, as if trying to start. Then the fuel supply stops and the engine does not start. Fuel comes back only after the DEC2 digital engine control system…Anonymous · 6 y▲0 rating0 commentsUsing a new bunker before the lab report arrives: precautionsProcedureMain EngineWhen a ship has to change over to a new bunker before the lab report arrives, I treat the fuel as suspect and run with extra precautions on fuel treatment and engines until the result is known. The…Anonymous · 4 y▲0 rating0 commentsOil tanker aux boilers: tests before cargo dischargeProcedureBoilerBefore cargo discharge on an oil tanker, I test the auxiliary boilers so they keep working through the discharge: boiler water, controls, and the pumps under load. This applies to any boiler maker…Anonymous · 4 y▲0 rating0 commentsThermal oil fire from a failing pump bearing, water mist did not work (Pride of Hull)IncidentPumps · Allweiler NTT 80-200 · ER fire alarm, zone "Oil treatment pumps"Ro-ro passenger ferry, outbound in the Humber. Thermal oil (Texatherm 32, winter set point 170 °C) carried heat from the economisers and a boiler. Circulation pump #1 was on duty. The fire panel…Anonymous · 4 y▲0 rating0 commentsCondition based maintenance on tankers and gas carriers: examplesKnowledgeMain Engine · MAN ES ME / MCCondition based maintenance (CBM) on tankers and gas carriers means working on equipment when its condition calls for it; these are the practical examples I use for the main engine, pumps and lube…Anonymous · 3 y▲0 rating0 commentsMAN 6S50ME-B: high exhaust temperature on all cylinders at part loadTroubleshootingMain Engine · MAN B&W 6S50ME-BAt 82–85 rpm (about 55% load; normal sea speed is 90 rpm), exhaust temperature rose on all six cylinders. Exhaust outlet temperatures were 416–437 °C, mean 427 °C. At sea trial this was about 340 °C.…Anonymous · 2 y▲0 rating0 commentsMAN ME: internal leak test on the hydraulic systemProcedureMain Engine · MAN ES ME-type main engineThis procedure is for MAN ES main engines with electronic control (ME type). It covers the hydraulic power supply (HPS) pumps, the hydraulic cylinder units (HCU) and the safety and accumulator block.…Anonymous · 4 y▲0 rating0 commentsMAN MC-C: no combustion in one unit, clogged ball valve at fuel pump inletTroubleshootingMain Engine · MAN B&W MC-C · Slowdown: exhaust gas temperature deviation, cylinder No.6Cylinder No.6 on our MAN MC-C stopped firing because the ball valve on the fuel oil inlet to its fuel pump was clogged. It took a long list of new parts before we found it. We reduced main engine…Anonymous · 4 y▲0 rating0 commentsTwo-stroke main engine: jobs to do while stopped in port or at anchorKnowledgeMain Engine · MAN ES ME / MCThis is my checklist of jobs to plan when the two-stroke main engine is stopped in port or at anchor and there is a good chance to do the work. It leaves out inspections that are due by running…Anonymous · 4 y▲0 rating0 commentsMAN B&W ME-C on VLSFO: which cylinder oil BN to useKnowledgeMain Engine · MAN B&W ME-CThere is no single right cylinder oil BN for MAN B&W ME-C two-stroke engines burning VLSFO (0.5 % sulphur): results depend on the engine and on how it is run. These are my notes from about three…Anonymous · 4 y▲0 rating0 commentsMAN B&W ES main engine: precautions for long low-load runningKnowledgeMain Engine · MAN B&W ESMAN Service Letter SL09-511/MTS gives 10% load as the lowest load for continuous running of a MAN B&W ES two-stroke main engine, and running in this range needs precautions. These are the precautions…Anonymous · 4 y▲0 rating0 commentsDiesel oil bunkering: tank overflow through a taped vent, engine room fire (Stride)IncidentBoiler · MAN B&W 7S70MC Mk6 · Diesel oil seen dripping from upper ER; no tank high-level alarm recordedGeneral cargo ship alongside at LaPorte, Texas, taking 80 mt of LSMGO into the port and starboard double-bottom DO tanks. The C/E and 3/E ran the bunkering from the ECR, with both fill valves open.…Anonymous · 1 y▲0 rating0 commentsHimsen 6H21/32: lowering the main bearing cap far enough to change the bearingKnowledgeAuxiliary Engine · Himsen 6H21/32When the main bearing cap is lowered with the special tool as the manual says, it goes down only 7–8 cm. That is not enough to change the bearing.Anonymous · 1 y▲0 rating0 commentsAft stern tube bearing wiped by partial propeller immersionKnowledgePropulsion & ThrustersRunning with the propeller not fully immersed puts off-centre thrust on the shaft, which edge-loads the aft stern tube bearing and can wipe its white metal within minutes. My main reference is DNV GL…Anonymous · 4 y