▲0 rating0 commentsWestfalia OSD 60-91: bowl does not close, ejection monitoring alarmTroubleshootingPurifier · Westfalia OSD 60-91 · Ejection monitoringTwo main engine LO separators stopped one after the other on the ejection monitoring alarm. On both, the bowl did not close at all. No discharge either, not even a small one. No. 1 stopped 1,000…Anonymous · 2 y▲0 rating0 commentsFresh water generator: checklist for low output or high salinityProcedureFresh Water GeneratorThis is my checklist for a fresh water generator (FWG) that makes too little water or gives high salinity in the distillate. It applies to a vacuum evaporator heated by engine jacket water, where an…Anonymous · 4 y▲0 rating0 commentsHow to take one cylinder out of service on MAN ME-CProcedureMain Engine · MAN ES ME-CTo take one cylinder unit out of operation on an ME-C (electronically controlled 2-stroke) main engine, I set the Chief Index limit for that cylinder to 0 on the MOP. This is an outline only. The…Anonymous · 4 y▲0 rating0 commentsSiemens LOGO! fuel changeover: program loaded but does not runTroubleshootingAutomation / PLC · Siemens LOGO! 230RC with DM8 230R and AM2 expansion modules · Control failThe automatic HFO/MDO changeover (valves and fuel heating) is controlled by a Siemens LOGO! 230RC with expansion modules. A "Control fail" alarm came up on the fuel page of the control PC. Expansion…Anonymous · 3 y▲0 rating0 commentsProvision plant compressor does not stop at pump-down, overcurrent tripTroubleshootingRefrigeration & HVACThe suction line has two low pressure switches: one stops the compressor, the other opens the unloader valve. When all cold room solenoid valves closed and suction pressure fell, the stop switch did…Anonymous · 7 y▲0 rating0 commentsMAN ME: exporting MOP event logs for remote troubleshootingProcedureMain Engine · MAN ES ME (electronically controlled), example engine 6S60ME-CThis is how I export the Event Log and the HCU, HPS and Cylinder Events from the MOP of a MAN ES (formerly MAN Diesel & Turbo) ME engine, to send to a remote troubleshooter. There are two parts:…Anonymous · 4 y▲0 rating0 commentsHFO to MGO changeover: cool slowly and watch viscosityProcedureMain EngineChanging the main engine and diesel generators from HFO to MGO is safe if fuel temperature falls slowly and viscosity stays between 2 cSt and 20 cSt. This is the general procedure I use; it follows…Anonymous · 3 y▲0 rating0 commentsOWS 15 ppm monitor cannot detect a blocked sampling lineKnowledgeOWS & Bilge · JOWA; Bilgemon488 15 ppm monitorA 15 ppm bilge alarm without a low sample flow switch cannot tell when its sampling line is closed or blocked, so the OWS can keep discharging overboard. A poorly placed sampling point can also make…Anonymous · 3 y▲0 rating0 commentsAlfa Laval plate FWG: high brine temperature (60 °C) and low outputTroubleshootingFresh Water Generator · Alfa Laval (plate type)Low fresh water output and brine temperature up to 60 °C. Cleaning the plates did not help. Vacuum and heating water were normal. Readings, the same before and after cleaning: Reading Value Heating…Anonymous · 10 mo▲0 rating0 commentsSAM Electronics ME HT cooling: temperature swings 8 °C in autoTroubleshootingMain Engine · SAM ElectronicsThe ME HT cooling water temperature controller (HT cooler valve) could not hold the set point in auto. The temperature went up and down by about 8 °C. Because of this, the system was run in manual…Anonymous · 1 y▲0 rating0 commentsCummins NTA855 emergency generator: speed hunts ±30 rpm after a cold startTroubleshootingAuxiliary Engine · Cummins NTA855-D(M)On the first cold start, speed hunted by about ±30 rpm at 1800 rpm (frequency by about 0.5 Hz). After a restart (sometimes the 2nd or 3rd) it ran smoothly, and further starts were fine. A few hours…Anonymous · 1 y▲0 rating0 commentsAux boiler explosion: waxy MGO, then fan restart into a gassy furnace (Manhattan Bridge)IncidentBoiler · "" · Aux boiler emergency trip (Furnace flame-eye abnormal)A 13,900 TEU container ship was berthing at Felixstowe in winter. The auxiliary boiler (rotary cup burner) had been on MGO for three days for the ECA. It tripped four times between 17:30 and 19:51.…Anonymous · 8 y▲0 rating0 commentsOil tanker aux boilers: tests before cargo dischargeProcedureBoilerBefore cargo discharge on an oil tanker, I test the auxiliary boilers so they keep working through the discharge: boiler water, controls, and the pumps under load. This applies to any boiler maker…Anonymous · 4 y▲0 rating0 commentsRolls-Royce steering gear: "Hydraulic lock" alarm at every small rudder movementTroubleshootingSteering Gear · Rolls-Royce · Hydraulic lock"Hydraulic lock" alarm on the steering gear. It started after a service in dry dock. At first it came now and then. Sometimes it cleared by itself, sometimes tightening the contacts helped. Later it…Anonymous · 2 y▲0 rating0 commentsAlfa Laval P615 oil purifier: bowl does not close, PT4 0.00TroubleshootingPurifier · Alfa Laval P615 · PT4 high at dischargeThe bowl did not close for a week. PT4 showed 0.00. A manual discharge gave the alarm "PT4 high at discharge".Anonymous · 2 y▲0 rating0 commentsWeishaupt Monarch burner sprays fuel as soon as the fan startsTroubleshootingBoiler · Weishaupt MonarchFuel sprayed from the nozzle as soon as the burner fan motor started, during pre-purge. It should spray only after purge, when the air damper closes, together with ignition. The burner started and…Anonymous · 6 y▲0 rating0 commentsAlfa Laval S956: "Bowl speed low" alarm during separationTroubleshootingPurifier · Alfa Laval S956 · Bowl speed low"Bowl speed low" alarm about twice a day. The alarm came during separation, not during discharge. Often it came about 10 hours into the cycle. Between alarms the separator started, reached speed and…Anonymous · 5 y▲0 rating0 commentsMAN B&W two-stroke: limits for judging engine performanceKnowledgeMain Engine · MAN B&W MC/MC-C, ME/ME-C/ME-BThis is my checklist of practical limits for judging the performance of MAN B&W two-stroke main engines, both mechanical (MC/MC-C) and electronic (ME/ME-C/ME-B). I don't have the source of the limits…Anonymous · 3 y▲0 rating0 commentsSEA-Mate B500 blender stops after blending, blend not dischargedTroubleshootingMain Engine · Marine Fluid Technology SEA-Mate Blender B500In auto mode the unit mixes the oils, then stops and stays stopped. It should open the valve and pump the blend on, but it does not. No alarm.Anonymous · 3 y▲0 rating0 commentsRunning the exhaust gas economizer dry: soot fire risk and precautionsProcedureBoilerAn exhaust gas economizer (exhaust gas boiler) can be run dry in an emergency, but the main risk is a soot fire: with no water inside, the tubes run hotter. This procedure lists the precautions I…Anonymous · 3 y▲0 rating0 commentsSea water cooling pump: no pressure and low current after overhaulTroubleshootingPumpsThe cooling sea water pump had just been overhauled, and a new motor was fitted: 25.3 kW, 39.5 A, 440 V delta, 1800 rpm. After start the pump gave no pressure. Motor current rose from 17 A to 24 A…Anonymous · 7 y▲0 rating0 commentsAlfa Laval SA820: "Sludge in bowl" alarm every day or two after overhaulTroubleshootingPurifier · Alfa Laval SA820 · Sludge in bowlAfter an overhaul the separator ran normally for several days. Then the "Sludge in bowl" alarm came every one or two days. The separator had tried to calibrate itself and could not close the bowl.Anonymous · 5 y▲0 rating0 commentsMain engine turbocharger surging: causes and preventionKnowledgeTurbochargerI wanted to know what turbocharger surging is and how to prevent it. One other engineer answered, and I accepted that answer. This is general guidance. It is not a real fault case. No engine or…Anonymous · 4 y▲0 rating0 commentsTwo-stroke load diagram: why the same mep is overload at low rpmKnowledgeMain Engine · MAN B&WOn a MAN B&W two-stroke load diagram, the same mep that is fine at high RPM counts as overload at low RPM because the torque limit is set mainly by the thermal load of engine components, with weak…Anonymous · 3 y▲0 rating0 commentsYanmar generator: low LO pressure shutdown 5 minutes after startTroubleshootingAuxiliary Engine · YanmarAfter start, LO pressure was normal (4.8 bar), then slowly fell. After 5–6 minutes at most, the engine shut down on low LO pressure. The differential pressure indicator on the automatic LO filter…Anonymous · 4 y▲0 rating0 commentsBoll & Kirch filter turns back to the dirty chamber at flushingTroubleshootingOther · Boll & Kirch 6.72, BK 2200 controllerAt backflushing: The solenoid worked and the filter turned to the clean chamber. The solenoid switched off, air was cut, and the filter turned back to the dirty chamber. This happened twice in a row.…Anonymous · 5 y▲0 rating0 commentsHow to inspect the scavenge space on a two-stroke main engineProcedureMain Engine · MAN ESThis is how I do a scavenge space inspection on a 2-stroke main engine through the scavenge ports in the liner, plus the checks I make for water carry-over. Inspect often. Regular checks let you see…Anonymous · 4 y▲0 rating0 commentsAMS Totem Plus: ME Alpha Lubricator alarms go into inhibitTroubleshootingAutomation / PLC · Totem Plus IMACSAt sea, all ME Alpha Lubricator alarms on the AMS (about 6 channels) went into inhibit by themselves. Real alarms on the Alpha Lubricator panel did not come to the AMS. Alpha Lubricator solenoid…Anonymous · 8 mo▲0 rating0 commentsRolls-Royce steering gear: one pump stops the rudder at 10° to one sideTroubleshootingSteering Gear · Rolls-RoyceWith one of the two pumps, the rudder would not go more than 10° to one side. Same in follow-up and non-follow-up. It stopped at exactly 10° every time, from any starting position. Pushing the…Anonymous · 7 y▲0 rating0 commentsEngine room flooding from a corroded sea water pipe at the strainer (Oliver Hazard Perry)IncidentAuxiliary Engine · John Deere diesel generator · AC power fault alarm on fire alarm panel, blackoutSail training tall ship (128 ft), two Caterpillar C12 propulsion engines, two John Deere DGs (99 kW). Moored, one crewmember on board. Shore power breakers kept tripping, so the port DG ran…Anonymous · 7 mo