Search

Cases

0 rating0 commentsNewins IC5000 cold room indicator shows LLLL after resetTroubleshootingRefrigeration & HVAC · Newins IC5000The cold chamber remote temperature indicator read 6 °C different from the real temperature. The settings were reset as the manual says: hold two keys while switching the power on. After the reset,…Anonymous · 1 y0 rating0 commentsME exhaust valve spindle burn-through: common causesKnowledgeMain EngineExhaust valve spindle burn-through on a two-stroke main engine usually comes from one of a short list of factors, each of which makes the spindle burn away faster and shortens the time between…Anonymous · 4 y0 rating0 commentsBoll & Kirch filter turns back to the dirty chamber at flushingTroubleshootingOther · Boll & Kirch 6.72, BK 2200 controllerAt backflushing: The solenoid worked and the filter turned to the clean chamber. The solenoid switched off, air was cut, and the filter turned back to the dirty chamber. This happened twice in a row.…Anonymous · 5 y0 rating0 commentsMAN ME: internal leak test on the hydraulic systemProcedureMain Engine · MAN ES ME-type main engineThis procedure is for MAN ES main engines with electronic control (ME type). It covers the hydraulic power supply (HPS) pumps, the hydraulic cylinder units (HCU) and the safety and accumulator block.…Anonymous · 4 y0 rating0 commentsTwo-stroke liner and ring scuffing: causes, symptoms and monitoringKnowledgeMain EngineScuffing is heavy adhesive wear of cylinder liners and piston rings in two-stroke engines that starts when the oil film breaks down, and it usually comes from several factors acting together. These…Anonymous · 3 y0 rating0 answersStern tube oil: high copper, cooler or pump wear suspectedTroubleshootingOpenPropulsion & ThrustersOur stern tube lube oil showed high copper (60-80 ppm); the cause is not confirmed, and I suspect wear in the oil cooler or circulating pumps rather than the bearing. Lab analysis of the stern tube…Anonymous · 4 y0 rating0 commentsStern tube oil: EAL vs mineral oil, downsides beyond priceKnowledgePropulsion & ThrustersBeyond its higher price, EAL (bio, biodegradable) stern tube oil has two risks compared with mineral oil: some EAL oils hold a weaker oil film under heavy load, and EAL oil is harmed by water…Anonymous · 4 y0 rating0 commentsMAN ES two-stroke: why the piston skirt has bronze bandsKnowledgeMain Engine · MAN Energy Solutions (2-stroke)The bronze bands on a MAN ES 2-stroke main engine piston skirt are there to keep adhesive wear on the cylinder liner low when the skirt touches the liner wall. This note explains how they work and…Anonymous · 2 y0 rating0 commentsShipboard electric motors: routine maintenance checks and testsKnowledgeElectricalPreventive maintenance of shipboard electric motors comes down to daily attention plus a few periodic checks and tests. The best thing I know is an electro-technical officer (ETO) on board who…Anonymous · 4 y0 rating0 commentsMAN B&W ES main engine: precautions for long low-load runningKnowledgeMain Engine · MAN B&W ESMAN Service Letter SL09-511/MTS gives 10% load as the lowest load for continuous running of a MAN B&W ES two-stroke main engine, and running in this range needs precautions. These are the precautions…Anonymous · 4 y0 rating0 commentsAft stern tube bearing wiped by partial propeller immersionKnowledgePropulsion & ThrustersRunning with the propeller not fully immersed puts off-centre thrust on the shaft, which edge-loads the aft stern tube bearing and can wipe its white metal within minutes. My main reference is DNV GL…Anonymous · 4 y0 rating0 commentsBent propeller blade tip: straightening in place, then PT checkProcedurePropulsion & ThrustersA bent propeller blade tip can be straightened in place by heating, by pressing, or both, followed by a dye penetrant (PT) check. This is the outline of how I did this repair; it is not a common job.…Anonymous · 3 y0 rating0 commentsSEA-Mate B500 blender stops after blending, blend not dischargedTroubleshootingMain Engine · Marine Fluid Technology SEA-Mate Blender B500In auto mode the unit mixes the oils, then stops and stays stopped. It should open the valve and pump the blend on, but it does not. No alarm.Anonymous · 3 y0 rating0 commentsDEIF PPM-3: busbar voltage read too low, generator will not auto-synchroniseTroubleshootingAutomation / PLC · DEIF PPM-3The DEIF PPM-3 controller of one generator measured the busbar voltage lower than it really was. The PMS saw a voltage fault. Auto synchronising was not possible, only manual. When the measured…Anonymous · 2 y0 rating0 commentsEmergency generator trips on blackout test, then will not close on the busTroubleshootingElectrical · Schneider Electric ComPacT NSX630Blackout test from the main switchboard: the supply to the emergency switchboard was switched off. The emergency generator started, closed onto the bus and took the load. After 5–10 minutes it…Anonymous · 6 mo0 rating0 commentsISO 4406 vs ISO 4407: oil cleanliness code vs particle countingKnowledgeMain Engine · MAN Energy Solutions ME / ME-B / ME-CISO 4406 is the cleanliness code MAN refers to for main engine system oil on its electronically controlled 2-stroke engines (ME type); ISO 4407 and ISO 11500 are particle counting methods. This note…Anonymous · 2 y0 rating0 commentsTwo-stroke main engine will not start without an auxiliary blowerKnowledgeMain EngineA two-stroke main engine (M/E) will not start unless at least one auxiliary blower is running; the control software blocks the start, so in practice it works as a start interlock. The M/E will start…Anonymous · 3 y0 rating0 commentsTwo-stroke piston rings: what cermet and alu-bronze coatings doKnowledgeMain EngineContext The engine type is a large two-stroke, slow-speed diesel main engine. A colleague asked me about the purpose of the two coatings on M/E piston rings: aluminium and cermet. I answered on the…Anonymous · 4 y0 rating0 answersMAN B&W ME: "Large deviation from model curve" alarm, worn HPS valves suspectedTroubleshootingOpenMain Engine · MAN B&W ME (electronic engine), exact model not stated · Large deviation from model curveThe "Large deviation from model curve" alarm on a MAN B&W ME engine most often points to a worn or defective proportional valve on an HPS pump. That is my working suspicion for the alarm on our…Anonymous · 3 y0 rating0 commentsTanker fixed gas sampling system: monthly and yearly checksKnowledgeFire & SafetyThe fixed gas sampling system on an oil tanker needs monthly crew checks (visual inspection, alarm test, zero and span calibration) plus, as good practice, a yearly health check by an authorized…Anonymous · 4 y0 rating0 commentsMain switchboard low insulation: find the fault by isolating loadsProcedureElectrical · Low insulationThis is how I find the cause of a low insulation alarm or low reading on the main switchboard (MSB): isolate all loads, then reconnect them one at a time while watching the insulation monitor. It…Anonymous · 4 y0 rating0 commentsDual-fuel VLCC: why deck LNG tanks have a water spray systemKnowledgeFire & SafetyThe water spray system around deck LNG fuel tanks has two jobs: it cools the tank and nearby structure in a fire, and it protects carbon steel deck and structure from brittle fracture if LNG leaks or…Anonymous · 4 y0 rating0 commentsMAN B&W ME: how cylinder prelubrication before start worksKnowledgeMain Engine · MAN B&W MEBackground The engine is a MAN B&W ME-type two-stroke main engine with Alpha cylinder lubricators. The ME hydraulic system pressure drives the lubricators. From the MOP (Main Operating Panel), the…Anonymous · 1 y0 rating0 commentsBallast pump coupling stuck: removed without heat using an extractor and jackTroubleshootingPumpsA stuck coupling flange on a tanker ballast pump can be pulled off without heat using a home-made extractor and a hydraulic jack. That is how we freed ours. The ballast pump sits in the pump room of…Anonymous · 2 y0 rating0 commentsBWTS in muddy ports: filters clog, how to ballast and when to bypassProcedureBallast SystemBallasting in very muddy water clogs and can damage the BWTS filter; this note covers how I ballast in those ports and when a bypass is allowed. In my experience this happens mostly in Chinese ports.…Anonymous · 4 y0 rating0 commentsWhy anchors and anchor chains are lost or damagedKnowledgeDeck MachineryAnchors and chains are lost or damaged through a mix of technical wear, operational mistakes and use beyond the design limits of the equipment. This is a general note, not one fault case. When…Anonymous · 4 y0 rating0 commentsHow to take one cylinder out of service on MAN ME-CProcedureMain Engine · MAN ES ME-CTo take one cylinder unit out of operation on an ME-C (electronically controlled 2-stroke) main engine, I set the Chief Index limit for that cylinder to 0 on the MOP. This is an outline only. The…Anonymous · 4 y0 rating0 commentsMain engine piston crowns burnt: long low-load running and bad injectorsTroubleshootingMain EngineBurn marks on our main engine piston crowns came, as far as we can tell, from long running at low load together with faulty fuel injectors. I found burn marks on the combustion side of the piston…Anonymous · 4 y0 rating0 commentsDiesel oil bunkering: tank overflow through a taped vent, engine room fire (Stride)IncidentBoiler · MAN B&W 7S70MC Mk6 · Diesel oil seen dripping from upper ER; no tank high-level alarm recordedGeneral cargo ship alongside at LaPorte, Texas, taking 80 mt of LSMGO into the port and starboard double-bottom DO tanks. The C/E and 3/E ran the bunkering from the ECR, with both fill valves open.…Anonymous · 1 y0 rating0 commentsAux engine room fire: slipped fuel pump coupling and exhaust leak (Finnmaster)IncidentAuxiliary Engine · Mitsubishi S12R · ER smoke alarm, then blackoutRo-ro leaving Hull with a pilot on board. AE1 had just been paralleled with AE2. Eight minutes after leaving the berth, smoke was detected in the aux engine room. Both AE2 exhaust temperature gauges…Anonymous · 1 y
Load more30 of 31 shown