0 rating0 commentsAC compressor loses oil pressure at start after overhaul with new partsTroubleshootingRefrigeration & HVAC · Low oil pressureThe air-conditioning compressors were overhauled with a new spare parts kit. After the overhaul, oil pressure dropped at every start.Anonymous · 1 y0 rating0 commentsYanmar generator: low LO pressure shutdown 5 minutes after startTroubleshootingAuxiliary Engine · YanmarAfter start, LO pressure was normal (4.8 bar), then slowly fell. After 5–6 minutes at most, the engine shut down on low LO pressure. The differential pressure indicator on the automatic LO filter…Anonymous · 4 y0 rating0 commentsSea water cooling pump: no pressure and low current after overhaulTroubleshootingPumpsThe cooling sea water pump had just been overhauled, and a new motor was fitted: 25.3 kW, 39.5 A, 440 V delta, 1800 rpm. After start the pump gave no pressure. Motor current rose from 17 A to 24 A…Anonymous · 7 y0 rating0 commentsMain engine: gas bubbles in the fuel system, fuel pressure jumpingTroubleshootingMain EngineAir (gas) bubbles in the main engine fuel oil system. Small bubbles stayed all the time. Fuel pressure was jumping.Anonymous · 1 y0 rating0 commentsTMC Tamrotor screw compressor: "R:3137 RUN INHIBIT", "check pressure in pipe"TroubleshootingCompressed Air · TMC Tamrotor EMH 21-44 · R:3137 RUN INHIBITThe display showed 6.0 bar and "R:3137 RUN INHIBIT". The manual has only two alarms marked R. For them it says: "check pressure in pipe".Anonymous · 1 y0 rating0 commentsMain engine: fuel pressure slowdowns, deaeration chamber full of gasTroubleshootingMain EngineRepeated main engine slowdowns on fuel oil pressure. It took about 4 days to find the cause. The deaeration chamber was "boiling" with gas. The gas came into the fuel system through the return line…Anonymous · 5 y0 rating0 commentsWestfalia OSD 18: weak sludge discharge when hydrophore pressure is lowTroubleshootingPurifier · Westfalia OSD 18Poor sludge discharge: no normal "bang", the bowl only "sneezes" and little comes out. Everything else worked correctly. With the hydrophore at 5.1–5.6 bar the discharge was normal. At 4.3 bar the…Anonymous · 4 y0 rating0 commentsMAN B&W ME: HPS pressure build-up time and decay checkKnowledgeMain Engine · MAN B&W MEOn a MAN B&W ME engine with one start-up pump running, I take an HPS pressure build-up time under 30 s as acceptable, and I also check the pressure decay time. The full maker requirements are in the…Anonymous · 3 y0 rating0 commentsBoiler feed pumps air-lock every few hours and trip on low pressureTroubleshootingBoilerBoiler feed water pumps get air-locked. After venting they run for 2–3 hours (sometimes up to 2 days), then the same again. Both pump motors trip. Low pressure alarms on the boiler panel, mostly at…Anonymous · 1 y0 rating0 commentsProvision plant compressor does not stop at pump-down, overcurrent tripTroubleshootingRefrigeration & HVACThe suction line has two low pressure switches: one stops the compressor, the other opens the unloader valve. When all cold room solenoid valves closed and suction pressure fell, the stop switch did…Anonymous · 7 y0 rating0 commentsWeishaupt Monarch burner: random "Air combustion low" at startTroubleshootingBoiler · Weishaupt Monarch · Air combustion lowThe burner tripped only at boiler start, two or three times a day. The alarm changed: sometimes "Air combustion low", sometimes "Flame failure". It was random: no alarm for 10 hours, then up to five…Anonymous · 4 y0 rating0 commentsOceanGuard BWTS: "EUT Power Abnormal" 10 s after startTroubleshootingBallast System · OceanGuard · EUT Power Abnormal AlarmThe BWTS worked normally 3 days before. Now, about 10 seconds after start, the alarm "EUT Power Abnormal Alarm" came up and the system stopped. The EUT power unit got its supply: LEDs on all modules…Anonymous · 3 y0 rating0 commentsHyundai steering gear: pump stops 4 seconds after start from the bridgeTroubleshootingSteering Gear · HyundaiIn the evening the running steering gear pump stopped, and the standby pump started. Started from the bridge (autopilot), the pump motor ran for about 4 seconds and then stopped. No alarms on the…Anonymous · 3 y0 rating0 commentsScrubber: "CEMS failure" alarm every 4 minutes, no alarm on the SICK analyserTroubleshootingOther · SICK CEMS · CEMS failureThe scrubber panel shows "CEMS failure" about every 4 minutes. Sometimes there is no alarm for about 20 minutes, then it comes back. The CEMS itself shows no new alarm. Its status goes to Stop and…Anonymous · 3 y0 rating0 commentsMAN 6S50ME-B: high exhaust temperature on all cylinders at part loadTroubleshootingMain Engine · MAN B&W 6S50ME-BAt 82–85 rpm (about 55% load; normal sea speed is 90 rpm), exhaust temperature rose on all six cylinders. Exhaust outlet temperatures were 416–437 °C, mean 427 °C. At sea trial this was about 340 °C.…Anonymous · 2 y0 rating0 commentsAlfa Laval SA805 lube oil separator: bowl opens by itself after about 10 hoursTroubleshootingPurifier · Alfa Laval SA805 · Low back pressureThe separator ran for about 10 hours, then the bowl opened by itself. The closing water went to the drain, and nothing held the bowl closed. Alarm: "Low back pressure". The other two separators…Anonymous · 4 y0 rating0 commentsAlfa Laval plate FWG: vacuum lost and will not come back past 60 %TroubleshootingFresh Water Generator · Alfa LavalFirst the salinity started to jump. One hour later the water level went out of the sight glass and the vacuum fell to 30 %. It all happened within a few hours. Before that, the vacuum built up in 30…Anonymous · 4 y0 rating0 commentsLNG dual-fuel ship: how the fuel gas supply system worksKnowledgeMain EngineThe fuel gas supply system (FGSS) on an LNG dual-fuel ship controls boil-off gas pressure in the LNG fuel tanks and turns LNG into gas for the engines and boilers; its design is set mainly by the…Anonymous · 3 y0 rating0 commentsMAN B&W two-stroke: limits for judging engine performanceKnowledgeMain Engine · MAN B&W MC/MC-C, ME/ME-C/ME-BThis is my checklist of practical limits for judging the performance of MAN B&W two-stroke main engines, both mechanical (MC/MC-C) and electronic (ME/ME-C/ME-B). I don't have the source of the limits…Anonymous · 3 y0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y0 rating0 commentsMAN ME: internal leak test on the hydraulic systemProcedureMain Engine · MAN ES ME-type main engineThis procedure is for MAN ES main engines with electronic control (ME type). It covers the hydraulic power supply (HPS) pumps, the hydraulic cylinder units (HCU) and the safety and accumulator block.…Anonymous · 4 y0 rating0 commentsRunning the exhaust gas economizer dry: soot fire risk and precautionsProcedureBoilerAn exhaust gas economizer (exhaust gas boiler) can be run dry in an emergency, but the main risk is a soot fire: with no water inside, the tubes run hotter. This procedure lists the precautions I…Anonymous · 3 y0 rating0 commentsVolvo Penta D16: con-rods through crankcase from swapped big-end caps (Wight Sky)IncidentMain Engine · Volvo Penta D16 MH · ME2 low LO pressure shutdown; ME4 common alarmRo-ro ferry with four Volvo Penta D16 MH high-speed MEs; one or two drive each Voith Schneider unit through fluid couplings. Wight Sky had three catastrophic ME failures in 15 months. The 2017 one…Anonymous · 4 y0 rating0 commentsStern tube air seal: risk of losing air supply at deep draftKnowledgePropulsion & ThrustersLoss of the air supply to a stern tube air seal is a serious condition, because at deep draft the oil head alone may not hold back seawater and seawater may enter the stern tube. Loss of air supply…Anonymous · 3 y0 rating0 commentsGenerator con-rod seizes and holes the block: oil run far past interval (Ocean Navigator)IncidentAuxiliary Engine · Caterpillar 3516B · ER fire alarm, AE2 low LO pressure and oil filter plugged, blackoutAE2 on a coastal cruise ship (Caterpillar 3516B, 1,800 rpm) had run its LO for more than 5,000 h and its filter elements for 3,329 h. Both should be changed at 1,000 h (LO longer only under…Anonymous · 1 y0 rating0 commentsMAN B&W ME: how cylinder prelubrication before start worksKnowledgeMain Engine · MAN B&W MEBackground The engine is a MAN B&W ME-type two-stroke main engine with Alpha cylinder lubricators. The ME hydraulic system pressure drives the lubricators. From the MOP (Main Operating Panel), the…Anonymous · 1 y0 rating0 commentsAlfa Laval plate FWG: high brine temperature (60 °C) and low outputTroubleshootingFresh Water Generator · Alfa Laval (plate type)Low fresh water output and brine temperature up to 60 °C. Cleaning the plates did not help. Vacuum and heating water were normal. Readings, the same before and after cleaning: Reading Value Heating…Anonymous · 10 mo0 rating0 commentsAux boiler explosion: waxy MGO, then fan restart into a gassy furnace (Manhattan Bridge)IncidentBoiler · "" · Aux boiler emergency trip (Furnace flame-eye abnormal)A 13,900 TEU container ship was berthing at Felixstowe in winter. The auxiliary boiler (rotary cup burner) had been on MGO for three days for the ECA. It tripped four times between 17:30 and 19:51.…Anonymous · 8 y0 rating0 commentsTwo-stroke main engine: jobs to do while stopped in port or at anchorKnowledgeMain Engine · MAN ES ME / MCThis is my checklist of jobs to plan when the two-stroke main engine is stopped in port or at anchor and there is a good chance to do the work. It leaves out inspections that are due by running…Anonymous · 4 y
Load more30 of 75 shown