▲0 rating0 commentsScania generator (DEC2): fires 2 or 3 times at start, then fuel is cut offTroubleshootingAuxiliary Engine · Scania, DEC2 digital engine controlThe diesel generator cranks and fires 2–3 times, as if trying to start. Then the fuel supply stops and the engine does not start. Fuel comes back only after the DEC2 digital engine control system…Anonymous · 6 y▲0 rating0 commentsTwo-stroke main engine will not start without an auxiliary blowerKnowledgeMain EngineA two-stroke main engine (M/E) will not start unless at least one auxiliary blower is running; the control software blocks the start, so in practice it works as a start interlock. The M/E will start…Anonymous · 3 y▲0 rating0 commentsEngine room fan trips its breaker when the soft starter switches to bypassTroubleshootingRefrigeration & HVAC · Schneider Altistart 48 (ATS48)The main engine room supply fan is reversible and is started by a soft starter with a bypass contactor. The soft starter ran the fan up normally in about 15 seconds. At the moment the bypass…Anonymous · 1 y▲0 rating0 commentsMAN B&W ME: how cylinder prelubrication before start worksKnowledgeMain Engine · MAN B&W MEBackground The engine is a MAN B&W ME-type two-stroke main engine with Alpha cylinder lubricators. The ME hydraulic system pressure drives the lubricators. From the MOP (Main Operating Panel), the…Anonymous · 1 y▲0 rating0 commentsCaterpillar 3408 generator will not start after blackoutTroubleshootingAuxiliary Engine · Caterpillar 3408The generator engine stopped and caused a blackout. Dirty fuel filters had let air into the fuel system. After the filters were changed, the engine cranked on the air starter but did not start.Anonymous · 3 y▲0 rating0 commentsEmergency generator: all alarms when the rack bracket is releasedKnowledgeAuxiliary EngineAfter a manual (emergency) start, the fuel rack is held by a locking bracket. If this bracket is released while the engine runs, the engine stops at once and all alarms come up together.Anonymous · 7 y▲0 rating0 commentsMAN B&W ME: HPS pressure build-up time and decay checkKnowledgeMain Engine · MAN B&W MEOn a MAN B&W ME engine with one start-up pump running, I take an HPS pressure build-up time under 30 s as acceptable, and I also check the pressure decay time. The full maker requirements are in the…Anonymous · 3 y▲0 rating0 commentsMAN B&W 7S70MC: fuel pump roller will not lower back after repair in portTroubleshootingMain Engine · MAN B&W 7S70MCAt sea, one fuel pump was cut out with the pneumatic fuel pump lifting device (roller lifted off the cam). The pump was repaired in port. The lifting device would not lower the roller back.Anonymous · 4 y▲0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y▲0 rating0 commentsDual-fuel main engine: loud bangs and many alarms when changing over to gasTroubleshootingMain EngineThe main engine was started and changed over to gas. Loud bangs from the engine and many alarms.Anonymous · 7 mo▲0 rating0 commentsFatal engine room fire after opening a pressurised fuel filter (Moritz Schulte)IncidentAuxiliary Engine · MAN B&W L23/30H · ER fire alarmLPG carrier discharging alongside in Antwerp. AE2 and AE3 were running and AE1 was on standby. After the morning toolbox talk the newly promoted 3/E asked the 2/E if he could clean the AE1 fuel…Anonymous · 3 y▲0 rating0 commentsMAN ME: internal leak test on the hydraulic systemProcedureMain Engine · MAN ES ME-type main engineThis procedure is for MAN ES main engines with electronic control (ME type). It covers the hydraulic power supply (HPS) pumps, the hydraulic cylinder units (HCU) and the safety and accumulator block.…Anonymous · 4 y▲0 rating0 commentsAux engine room fire: slipped fuel pump coupling and exhaust leak (Finnmaster)IncidentAuxiliary Engine · Mitsubishi S12R · ER smoke alarm, then blackoutRo-ro leaving Hull with a pilot on board. AE1 had just been paralleled with AE2. Eight minutes after leaving the berth, smoke was detected in the aux engine room. Both AE2 exhaust temperature gauges…Anonymous · 1 y▲0 rating0 commentsMAN B&W ES main engine: precautions for long low-load runningKnowledgeMain Engine · MAN B&W ESMAN Service Letter SL09-511/MTS gives 10% load as the lowest load for continuous running of a MAN B&W ES two-stroke main engine, and running in this range needs precautions. These are the precautions…Anonymous · 4 y▲0 rating0 commentsYanmar generator: low LO pressure shutdown 5 minutes after startTroubleshootingAuxiliary Engine · YanmarAfter start, LO pressure was normal (4.8 bar), then slowly fell. After 5–6 minutes at most, the engine shut down on low LO pressure. The differential pressure indicator on the automatic LO filter…Anonymous · 4 y▲0 rating0 commentsNabtesco governor: main engine will not go above 66 rpm, SCAVEN. LIMIT lamp onTroubleshootingMain Engine · Nabtesco governor control unit · M/E GOVERNOR SYSTEM ABNRThe main engine would not run faster than 66 rpm (Half Ahead). Scavenge air pressure was 0.2 bar. The auxiliary blowers were still running. On the governor control unit the SCAVEN. LIMIT lamp was on.…Anonymous · 3 y▲0 rating0 commentsEmergency generator will not crank on batteries that test OKTroubleshootingAuxiliary EngineThe emergency generator did not start on the electric starter, from the remote panel or from the local panel on the engine. The engine turned over once or twice, then stopped cranking. The start…Anonymous · 4 y▲0 rating0 commentsEngine room fire: fuel backflow through an open return line (Scot Stuttgart)IncidentAuxiliary Engine · "" · ER fire alarm, thick white smoke in port ERChemical tanker with two engine rooms, alongside in San Juan discharging cargo. The port AE was under LOTO for turbocharger and aftercooler cleaning. The crew removed the aftercooler and the fuel…Anonymous · 2 mo▲0 rating0 answersMain engine scavenge drain tank level rising: piston crown O-ring leak suspectedTroubleshootingOpenMain EngineThe level in our main engine scavenge drain tank keeps going up, and I suspect system oil leaking into the scavenge space from the piston crown O-rings. The engine has a scavenge space, so it is most…Anonymous · 3 y▲0 rating0 commentsHFO to MGO changeover: cool slowly and watch viscosityProcedureMain EngineChanging the main engine and diesel generators from HFO to MGO is safe if fuel temperature falls slowly and viscosity stays between 2 cSt and 20 cSt. This is the general procedure I use; it follows…Anonymous · 3 y▲0 rating0 commentsDiesel oil bunkering: tank overflow through a taped vent, engine room fire (Stride)IncidentBoiler · MAN B&W 7S70MC Mk6 · Diesel oil seen dripping from upper ER; no tank high-level alarm recordedGeneral cargo ship alongside at LaPorte, Texas, taking 80 mt of LSMGO into the port and starboard double-bottom DO tanks. The C/E and 3/E ran the bunkering from the ECR, with both fill valves open.…Anonymous · 1 y▲0 rating0 commentsHow to take one cylinder out of service on MAN ME-CProcedureMain Engine · MAN ES ME-CTo take one cylinder unit out of operation on an ME-C (electronically controlled 2-stroke) main engine, I set the Chief Index limit for that cylinder to 0 on the MOP. This is an outline only. The…Anonymous · 4 y▲0 rating0 commentsKongsberg DGU 8800e governor switches off a few minutes after startTroubleshootingMain Engine · Kongsberg DGU 8800eThe main engine governor unit would not stay on. After the power button inside the unit, two green LEDs lit. The unit tried to boot, then switched off. When cold (after being off for a while), it…Anonymous · 4 y▲0 rating0 commentsEngine room flooding from a corroded sea water pipe at the strainer (Oliver Hazard Perry)IncidentAuxiliary Engine · John Deere diesel generator · AC power fault alarm on fire alarm panel, blackoutSail training tall ship (128 ft), two Caterpillar C12 propulsion engines, two John Deere DGs (99 kW). Moored, one crewmember on board. Shore power breakers kept tripping, so the port DG ran…Anonymous · 7 mo▲0 rating0 commentsMAN ME-C: running with one HPS pump in fail modeKnowledgeMain Engine · MAN Energy Solutions ME-CWith one of three HPS pumps in "fail", an ME-C main engine can usually keep full function if the fault is only electronic or in the cables; a mechanical fault is a different case. These are my notes…Anonymous · 3 y▲0 rating0 commentsBunker fuel quality: ISO 8217 fuel can still cause engine problemsKnowledgeMain EngineThese are my general notes about bunker fuel quality. They do not describe a real fault on a ship. I give no engine maker, no readings and no test results. I wrote them in two parts. Main point…Anonymous · 2 y▲0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y▲0 rating0 commentsGenerator engine fails on non-OEM bearings run to OEM intervals (Kommandor Susan)IncidentAuxiliary Engine · Caterpillar 3516B-TA · ER fire alarm, blackoutDiesel-electric vessel on sea trials, just out of the lock at Leith with a pilot on board. DG1 and DG4 were on line. The C/E heard a change in engine note on one generator, then a loud bang. The fire…Anonymous · 6 mo▲0 rating0 commentsDoosan emergency generator: testing overspeed without a test buttonKnowledgeAuxiliary Engine · Doosan AD136TS, KMC ECMS-850EH · OverspeedThe set: Doosan AD136TS engine (1800 rpm, 125 kW) with a KMC ECMS-850EH engine control and monitoring system. The wiring diagram in the manual shows a GAC ESD5550 speed control unit with "TEST…Anonymous · 3 y▲0 rating0 commentsKongsberg K-Chief 600: "ME SBW pot.meter" alarm after lever calibrationTroubleshootingMain Engine · Kongsberg K-Chief 600 · ME SBW POT.METERThe telegraph lever on the starboard bridge wing was calibrated. The calibration went normally. At the next manoeuvring the alarm "Lock in Last 'Speed Set Bridge'" came. It cleared. The alarm "ME SBW…Anonymous · 2 y▲0 rating0 commentsMAN 48/60: con-rod small end breaks after bad bush renewal (Finlandia Seaways)IncidentMain Engine · MAN 12V48/60 · Crankcase oil mist high, No. 6 main bearing temp highRo-ro at sea, single MAN 12V48/60 at 500 rpm, 110 662 running hours. The on-watch 3/E was in the purifier room when he heard loud metallic knocking. The bridge felt heavy vibration and saw pitch and…Anonymous · 5 y▲0 rating0 commentsMAN ME: exporting MOP event logs for remote troubleshootingProcedureMain Engine · MAN ES ME (electronically controlled), example engine 6S60ME-CThis is how I export the Event Log and the HCU, HPS and Cylinder Events from the MOP of a MAN ES (formerly MAN Diesel & Turbo) ME engine, to send to a remote troubleshooter. There are two parts:…Anonymous · 4 y▲0 rating0 commentsStandard bearing shell on an undersize journal: con-rods break out (Ocean Guardian)IncidentAuxiliary Engine · Caterpillar 3516B · No alarm; loud bang, then smoke and fire in ERDiesel-electric offshore supply vessel, four Caterpillar 3516B main DGs (1,990 kW each). All four were overhauled by shore technicians in early 2022. On sea trials, DG3 had run about 4 h since…Anonymous · 3 y▲0 rating0 commentsHyundai generator: no voltage at start after a 440 V insulation alarmTroubleshootingElectrical · Hyundai HFC7The 440 V insulation reading started to jump between 0 and infinity. Three generators were on the bus. Two were taken off, only No. 3 was left. Next day generator No. 1 was started, but it did not…Anonymous · 4 y▲0 rating0 commentsTwo-stroke liner and ring scuffing: causes, symptoms and monitoringKnowledgeMain EngineScuffing is heavy adhesive wear of cylinder liners and piston rings in two-stroke engines that starts when the oil film breaks down, and it usually comes from several factors acting together. These…Anonymous · 3 y▲0 rating0 commentsVolvo Penta D16: con-rods through crankcase from swapped big-end caps (Wight Sky)IncidentMain Engine · Volvo Penta D16 MH · ME2 low LO pressure shutdown; ME4 common alarmRo-ro ferry with four Volvo Penta D16 MH high-speed MEs; one or two drive each Voith Schneider unit through fluid couplings. Wight Sky had three catastrophic ME failures in 15 months. The 2017 one…Anonymous · 4 y▲0 rating0 commentsOpen-loop SOx scrubber: common problems with pipes, sensors and pumpsKnowledgeOtherThese are the usual trouble spots on SOx scrubbers, from my experience and from one other engineer. We both talk about open-loop systems. I do not name a ship, engine or scrubber maker here. This is…Anonymous · 4 y▲0 rating0 commentsTerasaki PMS: generator will not parallel in auto, "ACB non close"TroubleshootingElectrical · Terasaki PMS · ACB non closeWhen a generator was put in parallel in automatic mode, the alarm "ACB non close" came up. The breaker did not close and the engine stayed running with no load. Frequency and voltage were the same as…Anonymous · 4 y▲0 rating0 commentsMAN MC-C: no combustion in one unit, clogged ball valve at fuel pump inletTroubleshootingMain Engine · MAN B&W MC-C · Slowdown: exhaust gas temperature deviation, cylinder No.6Cylinder No.6 on our MAN MC-C stopped firing because the ball valve on the fuel oil inlet to its fuel pump was clogged. It took a long list of new parts before we found it. We reduced main engine…Anonymous · 4 y▲0 rating0 comments220 V insulation alarm every morning, gone before you reach the switchboardTroubleshootingElectrical · Low insulation 220 VLow insulation alarm on the 220 V system early every morning, at breakfast time. By the time the engineer reached the switchboard, the reading was normal again. It started when a new cook joined the…Anonymous · 2 y▲0 rating0 commentsMAN ME-C: "Low stroke" slowdown, exhaust valve position signal drops outTroubleshootingMain Engine · MAN B&W ME-C · Low strokeMain engine slowdown with "Low stroke" alarm on one cylinder. On the MOP, the exhaust valve position signal from the inductive sensor dropped out about every 3 seconds. Each time, fuel injection to…Anonymous · 8 mo▲0 rating0 commentsThermal oil fire from a failing pump bearing, water mist did not work (Pride of Hull)IncidentPumps · Allweiler NTT 80-200 · ER fire alarm, zone "Oil treatment pumps"Ro-ro passenger ferry, outbound in the Humber. Thermal oil (Texatherm 32, winter set point 170 °C) carried heat from the economisers and a boiler. Circulation pump #1 was on duty. The fire panel…Anonymous · 4 y▲0 rating0 commentsCPP hub oil loss from a cracked blade foot, not a blade seal (Maunalei)IncidentPropulsion & Thrusters · MAN Energy Solutions Mark 5 CPP; MAN B&W 7L70MC-C · Engineering alarm, CPP hub head tank found emptyContainership, MAN B&W 7L70MC-C two-stroke ME directly coupled to a 5-blade MAN Mark 5 CPP. On passage to Anchorage an alarm came up: CPP hub head tank empty. The crew reduced pitch and refilled the…Anonymous · 2 y▲0 rating0 commentsWestfalia OSD 60-91: bowl does not close, ejection monitoring alarmTroubleshootingPurifier · Westfalia OSD 60-91 · Ejection monitoringTwo main engine LO separators stopped one after the other on the ejection monitoring alarm. On both, the bowl did not close at all. No discharge either, not even a small one. No. 1 stopped 1,000…Anonymous · 2 y▲0 rating0 commentsGenerator overhaul: checklist to prevent con-rod failures afterwardsProcedureAuxiliary EngineMost serious damage to an auxiliary diesel generator (D/G) comes a few hours after a general overhaul, usually from connecting rod or rod bolt failure; this is the checklist I use to prevent it. It…Anonymous · 4 y▲0 rating0 commentsMAN 6S50ME-C: unit loses compression 10 minutes after overhaulTroubleshootingMain Engine · MAN B&W 6S50ME-CUnit 1 of the main engine was overhauled. Tests in port were normal. About 10 minutes after leaving port, the unit started knocking and lost compression. After a restart the unit worked again, but…Anonymous · 4 y▲0 rating0 commentsBallast valve remote control: half the valves stop responding, no alarmTroubleshootingBallast System · Utsuki valve remote control, Yokogawa FA-M3 PLCAbout half of the hydraulic ballast valves stopped responding, all at the same time. No reaction from the ballast console or from the local control panel. No alarms. The valves could still be moved…Anonymous · 6 y▲0 rating0 commentsRunning the exhaust gas economizer dry: soot fire risk and precautionsProcedureBoilerAn exhaust gas economizer (exhaust gas boiler) can be run dry in an emergency, but the main risk is a soot fire: with no water inside, the tubes run hotter. This procedure lists the precautions I…Anonymous · 3 y▲0 rating0 commentsMain switchboard low insulation: find the fault by isolating loadsProcedureElectrical · Low insulationThis is how I find the cause of a low insulation alarm or low reading on the main switchboard (MSB): isolate all loads, then reconnect them one at a time while watching the insulation monitor. It…Anonymous · 4 y▲0 rating0 commentsPods stuck at 90° after overspeed trip and a latched water-leak stop (Spirit of Discovery)IncidentPropulsion & Thrusters · Siemens SISHIp eSiPOD (SiPOD-M10) · Pod water leakage stop (WLS) sequence alarm, then propeller overspeedCruise ship with two Siemens eSiPOD pods (6,500 kW each, no rudder), crossing the Bay of Biscay in force 8–9 wind and 8–9 m waves. At 12:30 the port pod gave a WLS sequence alarm. Very soon after, it…Anonymous · 8 mo