▲0 rating0 commentsTwo-stroke main engine: jobs to do while stopped in port or at anchorKnowledgeMain Engine · MAN ES ME / MCThis is my checklist of jobs to plan when the two-stroke main engine is stopped in port or at anchor and there is a good chance to do the work. It leaves out inspections that are due by running…Anonymous · 4 y▲0 rating0 commentsDual-fuel main engine: loud bangs and many alarms when changing over to gasTroubleshootingMain EngineThe main engine was started and changed over to gas. Loud bangs from the engine and many alarms.Anonymous · 7 mo▲0 rating0 commentsMain engine: fuel pressure slowdowns, deaeration chamber full of gasTroubleshootingMain EngineRepeated main engine slowdowns on fuel oil pressure. It took about 4 days to find the cause. The deaeration chamber was "boiling" with gas. The gas came into the fuel system through the return line…Anonymous · 5 y▲0 rating0 commentsTwo-stroke main engine will not start without an auxiliary blowerKnowledgeMain EngineA two-stroke main engine (M/E) will not start unless at least one auxiliary blower is running; the control software blocks the start, so in practice it works as a start interlock. The M/E will start…Anonymous · 3 y▲0 rating0 commentsMain engine: gas bubbles in the fuel system, fuel pressure jumpingTroubleshootingMain EngineAir (gas) bubbles in the main engine fuel oil system. Small bubbles stayed all the time. Fuel pressure was jumping.Anonymous · 1 y▲0 rating0 commentsNabtesco governor: main engine will not go above 66 rpm, SCAVEN. LIMIT lamp onTroubleshootingMain Engine · Nabtesco governor control unit · M/E GOVERNOR SYSTEM ABNRThe main engine would not run faster than 66 rpm (Half Ahead). Scavenge air pressure was 0.2 bar. The auxiliary blowers were still running. On the governor control unit the SCAVEN. LIMIT lamp was on.…Anonymous · 3 y▲0 rating0 commentsMain engine EGR: deposits and wear depend mainly on fuel sulphurKnowledgeMain EngineOn a two-stroke main engine EGR (exhaust gas recirculation) system, fuel sulphur content is the main factor behind deposits in the air cooler and scavenge receiver and the amount of drain water and…Anonymous · 4 y▲0 rating0 answersMain engine scavenge drain tank level rising: piston crown O-ring leak suspectedTroubleshootingOpenMain EngineThe level in our main engine scavenge drain tank keeps going up, and I suspect system oil leaking into the scavenge space from the piston crown O-rings. The engine has a scavenge space, so it is most…Anonymous · 3 y▲0 rating0 commentsMain engine liners: how often to do external wear scanningKnowledgeMain EngineExternal electronic scanning of main engine cylinder liners by an outside company is worth doing; what is not settled is how often, at least yearly or about every 5 years backed by onboard…Anonymous · 4 y▲0 rating0 commentsMain engine turbocharger surging: causes and preventionKnowledgeTurbochargerI wanted to know what turbocharger surging is and how to prevent it. One other engineer answered, and I accepted that answer. This is general guidance. It is not a real fault case. No engine or…Anonymous · 4 y▲0 rating0 commentsMAN B&W ES main engine: precautions for long low-load runningKnowledgeMain Engine · MAN B&W ESMAN Service Letter SL09-511/MTS gives 10% load as the lowest load for continuous running of a MAN B&W ES two-stroke main engine, and running in this range needs precautions. These are the precautions…Anonymous · 4 y▲0 rating0 commentsCondition based maintenance on tankers and gas carriers: examplesKnowledgeMain Engine · MAN ES ME / MCCondition based maintenance (CBM) on tankers and gas carriers means working on equipment when its condition calls for it; these are the practical examples I use for the main engine, pumps and lube…Anonymous · 3 y▲0 rating0 commentsMain engine piston crowns burnt: long low-load running and bad injectorsTroubleshootingMain EngineBurn marks on our main engine piston crowns came, as far as we can tell, from long running at low load together with faulty fuel injectors. I found burn marks on the combustion side of the piston…Anonymous · 4 y▲0 rating0 commentsMAN B&W main engine in heavy weather: torque vs rpm governor modeKnowledgeMain Engine · MAN B&W ME-B / ME-C, MCTo protect the main engine liners and piston rings in heavy weather, I reduce RPM and choose the governor mode with care: on ME-B and ME-C engines that means weighing Torque mode against RPM mode.…Anonymous · 3 y▲0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y▲0 rating0 commentsLNG dual-fuel ship: how the fuel gas supply system worksKnowledgeMain EngineThe fuel gas supply system (FGSS) on an LNG dual-fuel ship controls boil-off gas pressure in the LNG fuel tanks and turns LNG into gas for the engines and boilers; its design is set mainly by the…Anonymous · 3 y▲0 rating0 commentsStandard bearing shell on an undersize journal: con-rods break out (Ocean Guardian)IncidentAuxiliary Engine · Caterpillar 3516B · No alarm; loud bang, then smoke and fire in ERDiesel-electric offshore supply vessel, four Caterpillar 3516B main DGs (1,990 kW each). All four were overhauled by shore technicians in early 2022. On sea trials, DG3 had run about 4 h since…Anonymous · 3 y▲0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y▲0 rating0 commentsHow to inspect the scavenge space on a two-stroke main engineProcedureMain Engine · MAN ESThis is how I do a scavenge space inspection on a 2-stroke main engine through the scavenge ports in the liner, plus the checks I make for water carry-over. Inspect often. Regular checks let you see…Anonymous · 4 y▲0 rating0 commentsWinGD DF engine: running on VLSFO with a seized pilot fuel pumpKnowledgeMain Engine · WinGD DFThe pilot fuel pump seized. The question was how long the engine can run without it before the pilot injector nozzle holes coke up. The engine ran on VLSFO for 10 days with no pilot fuel supply. When…Anonymous · 1 y▲0 rating0 commentsEngine room fan trips its breaker when the soft starter switches to bypassTroubleshootingRefrigeration & HVAC · Schneider Altistart 48 (ATS48)The main engine room supply fan is reversible and is started by a soft starter with a bypass contactor. The soft starter ran the fan up normally in about 15 seconds. At the moment the bypass…Anonymous · 1 y▲0 rating0 commentsMAN ME: internal leak test on the hydraulic systemProcedureMain Engine · MAN ES ME-type main engineThis procedure is for MAN ES main engines with electronic control (ME type). It covers the hydraulic power supply (HPS) pumps, the hydraulic cylinder units (HCU) and the safety and accumulator block.…Anonymous · 4 y▲0 rating0 commentsME exhaust valve spindle burn-through: common causesKnowledgeMain EngineExhaust valve spindle burn-through on a two-stroke main engine usually comes from one of a short list of factors, each of which makes the spindle burn away faster and shortens the time between…Anonymous · 4 y▲0 rating0 commentsVolvo Penta D16: con-rods through crankcase from swapped big-end caps (Wight Sky)IncidentMain Engine · Volvo Penta D16 MH · ME2 low LO pressure shutdown; ME4 common alarmRo-ro ferry with four Volvo Penta D16 MH high-speed MEs; one or two drive each Voith Schneider unit through fluid couplings. Wight Sky had three catastrophic ME failures in 15 months. The 2017 one…Anonymous · 4 y▲0 rating0 commentsMain switchboard low insulation: find the fault by isolating loadsProcedureElectrical · Low insulationThis is how I find the cause of a low insulation alarm or low reading on the main switchboard (MSB): isolate all loads, then reconnect them one at a time while watching the insulation monitor. It…Anonymous · 4 y▲0 rating0 commentsMAN MC-C: no combustion in one unit, clogged ball valve at fuel pump inletTroubleshootingMain Engine · MAN B&W MC-C · Slowdown: exhaust gas temperature deviation, cylinder No.6Cylinder No.6 on our MAN MC-C stopped firing because the ball valve on the fuel oil inlet to its fuel pump was clogged. It took a long list of new parts before we found it. We reduced main engine…Anonymous · 4 y▲0 rating0 commentsTwo-stroke load diagram: why the same mep is overload at low rpmKnowledgeMain Engine · MAN B&WOn a MAN B&W two-stroke load diagram, the same mep that is fine at high RPM counts as overload at low RPM because the torque limit is set mainly by the thermal load of engine components, with weak…Anonymous · 3 y▲0 rating0 commentsMAN 48/60: con-rod small end breaks after bad bush renewal (Finlandia Seaways)IncidentMain Engine · MAN 12V48/60 · Crankcase oil mist high, No. 6 main bearing temp highRo-ro at sea, single MAN 12V48/60 at 500 rpm, 110 662 running hours. The on-watch 3/E was in the purifier room when he heard loud metallic knocking. The bridge felt heavy vibration and saw pitch and…Anonymous · 5 y▲0 rating0 commentsKongsberg K-Chief 600: "ME SBW pot.meter" alarm after lever calibrationTroubleshootingMain Engine · Kongsberg K-Chief 600 · ME SBW POT.METERThe telegraph lever on the starboard bridge wing was calibrated. The calibration went normally. At the next manoeuvring the alarm "Lock in Last 'Speed Set Bridge'" came. It cleared. The alarm "ME SBW…Anonymous · 2 y▲0 rating0 commentsMAN ME-C: running with one HPS pump in fail modeKnowledgeMain Engine · MAN Energy Solutions ME-CWith one of three HPS pumps in "fail", an ME-C main engine can usually keep full function if the fault is only electronic or in the cables; a mechanical fault is a different case. These are my notes…Anonymous · 3 y▲0 rating0 commentsUsing a new bunker before the lab report arrives: precautionsProcedureMain EngineWhen a ship has to change over to a new bunker before the lab report arrives, I treat the fuel as suspect and run with extra precautions on fuel treatment and engines until the result is known. The…Anonymous · 4 y▲0 rating0 commentsMAN ES two-stroke: why the piston skirt has bronze bandsKnowledgeMain Engine · MAN Energy Solutions (2-stroke)The bronze bands on a MAN ES 2-stroke main engine piston skirt are there to keep adhesive wear on the cylinder liner low when the skirt touches the liner wall. This note explains how they work and…Anonymous · 2 y▲0 rating0 commentsMAN B&W ME: how cylinder prelubrication before start worksKnowledgeMain Engine · MAN B&W MEBackground The engine is a MAN B&W ME-type two-stroke main engine with Alpha cylinder lubricators. The ME hydraulic system pressure drives the lubricators. From the MOP (Main Operating Panel), the…Anonymous · 1 y▲0 rating0 commentsFuel oil purifiers: how to remove more cat finesKnowledgePurifierTo remove more catalytic fines (cat fines), fuel oil purifiers (centrifugal separators) need low throughput, the right temperature and good maintenance. These are my general notes; there is no…Anonymous · 4 y▲0 rating0 commentsEngine room fire: fuel backflow through an open return line (Scot Stuttgart)IncidentAuxiliary Engine · "" · ER fire alarm, thick white smoke in port ERChemical tanker with two engine rooms, alongside in San Juan discharging cargo. The port AE was under LOTO for turbocharger and aftercooler cleaning. The crew removed the aftercooler and the fuel…Anonymous · 2 mo▲0 rating0 commentsHow to take one cylinder out of service on MAN ME-CProcedureMain Engine · MAN ES ME-CTo take one cylinder unit out of operation on an ME-C (electronically controlled 2-stroke) main engine, I set the Chief Index limit for that cylinder to 0 on the MOP. This is an outline only. The…Anonymous · 4 y▲0 rating0 commentsHFO to MGO changeover: cool slowly and watch viscosityProcedureMain EngineChanging the main engine and diesel generators from HFO to MGO is safe if fuel temperature falls slowly and viscosity stays between 2 cSt and 20 cSt. This is the general procedure I use; it follows…Anonymous · 3 y▲0 rating0 commentsWestfalia OSD 60-91: bowl does not close, ejection monitoring alarmTroubleshootingPurifier · Westfalia OSD 60-91 · Ejection monitoringTwo main engine LO separators stopped one after the other on the ejection monitoring alarm. On both, the bowl did not close at all. No discharge either, not even a small one. No. 1 stopped 1,000…Anonymous · 2 y▲0 rating0 commentsFuel treatment chemicals: why engine makers prefer good fuel managementKnowledgeMain EngineThe big makers of main and generator engines prefer good fuel management to fuel treatment chemicals; they have not confirmed the claimed benefits of additives. The one exception I make is a…Anonymous · 4 y▲0 rating0 commentsTanker fixed gas sampling system: monthly and yearly checksKnowledgeFire & SafetyThe fixed gas sampling system on an oil tanker needs monthly crew checks (visual inspection, alarm test, zero and span calibration) plus, as good practice, a yearly health check by an authorized…Anonymous · 4 y▲0 rating0 answersMAN B&W ME: "Large deviation from model curve" alarm, worn HPS valves suspectedTroubleshootingOpenMain Engine · MAN B&W ME (electronic engine), exact model not stated · Large deviation from model curveThe "Large deviation from model curve" alarm on a MAN B&W ME engine most often points to a worn or defective proportional valve on an HPS pump. That is my working suspicion for the alarm on our…Anonymous · 3 y▲0 rating0 commentsTwo-stroke piston rings: what cermet and alu-bronze coatings doKnowledgeMain EngineContext The engine type is a large two-stroke, slow-speed diesel main engine. A colleague asked me about the purpose of the two coatings on M/E piston rings: aluminium and cermet. I answered on the…Anonymous · 4 y▲0 rating0 commentsISO 4406 vs ISO 4407: oil cleanliness code vs particle countingKnowledgeMain Engine · MAN Energy Solutions ME / ME-B / ME-CISO 4406 is the cleanliness code MAN refers to for main engine system oil on its electronically controlled 2-stroke engines (ME type); ISO 4407 and ISO 11500 are particle counting methods. This note…Anonymous · 2 y▲0 rating0 commentsMAN ME HCU and HPS event logs: compare only with the same engineKnowledgeMain Engine · MAN Energy Solutions ME (electronically controlled)HCU and HPS event logs from the MOP are a useful troubleshooting tool on MAN ES ME engines, but you can only compare events from the same engine. These are my notes on what the events are, how I view…Anonymous · 3 y▲0 rating0 commentsRunning the exhaust gas economizer dry: soot fire risk and precautionsProcedureBoilerAn exhaust gas economizer (exhaust gas boiler) can be run dry in an emergency, but the main risk is a soot fire: with no water inside, the tubes run hotter. This procedure lists the precautions I…Anonymous · 3 y▲0 rating0 commentsBunker fuel quality: ISO 8217 fuel can still cause engine problemsKnowledgeMain EngineThese are my general notes about bunker fuel quality. They do not describe a real fault on a ship. I give no engine maker, no readings and no test results. I wrote them in two parts. Main point…Anonymous · 2 y▲0 rating0 commentsKongsberg DGU 8800e governor switches off a few minutes after startTroubleshootingMain Engine · Kongsberg DGU 8800eThe main engine governor unit would not stay on. After the power button inside the unit, two green LEDs lit. The unit tried to boot, then switched off. When cold (after being off for a while), it…Anonymous · 4 y▲0 rating0 commentsAlpha Lubricator: "Feedback failure" slowdown comes and goesTroubleshootingMain Engine · MAN B&W Alpha Lubricator · Feedback failureMain engine slowdown from the Alpha Lubricator system, alarm "Feedback failure". The alarm came for 5 to 60 seconds and then cleared by itself. In the menu it showed as Alarm 3. By the manual, Alarm…Anonymous · 4 y▲0 rating0 commentsShaft torque meters with strain gauges: calibrate every 6 monthsKnowledgePropulsion & ThrustersI recommend calibrating shaft torque meters (shaft power meters) on the propulsion shafting every 6 months, at least those with strain gauges, because regular calibration stops the strain-gauge…Anonymous · 4 y▲0 rating0 commentsAft stern tube bearing wiped by partial propeller immersionKnowledgePropulsion & ThrustersRunning with the propeller not fully immersed puts off-centre thrust on the shaft, which edge-loads the aft stern tube bearing and can wipe its white metal within minutes. My main reference is DNV GL…Anonymous · 4 y▲0 rating0 commentsTwo-stroke liner and ring scuffing: causes, symptoms and monitoringKnowledgeMain EngineScuffing is heavy adhesive wear of cylinder liners and piston rings in two-stroke engines that starts when the oil film breaks down, and it usually comes from several factors acting together. These…Anonymous · 3 y▲0 rating0 commentsMAN ME-C: "Low stroke" slowdown, exhaust valve position signal drops outTroubleshootingMain Engine · MAN B&W ME-C · Low strokeMain engine slowdown with "Low stroke" alarm on one cylinder. On the MOP, the exhaust valve position signal from the inductive sensor dropped out about every 3 seconds. Each time, fuel injection to…Anonymous · 8 mo▲0 rating0 commentsMAN 6S50ME-C: unit loses compression 10 minutes after overhaulTroubleshootingMain Engine · MAN B&W 6S50ME-CUnit 1 of the main engine was overhauled. Tests in port were normal. About 10 minutes after leaving port, the unit started knocking and lost compression. After a restart the unit worked again, but…Anonymous · 4 y▲0 rating0 commentsGenerator engine fails on non-OEM bearings run to OEM intervals (Kommandor Susan)IncidentAuxiliary Engine · Caterpillar 3516B-TA · ER fire alarm, blackoutDiesel-electric vessel on sea trials, just out of the lock at Leith with a pilot on board. DG1 and DG4 were on line. The C/E heard a change in engine note on one generator, then a loud bang. The fire…Anonymous · 6 mo▲0 rating0 commentsEngine room flooding from a corroded sea water pipe at the strainer (Oliver Hazard Perry)IncidentAuxiliary Engine · John Deere diesel generator · AC power fault alarm on fire alarm panel, blackoutSail training tall ship (128 ft), two Caterpillar C12 propulsion engines, two John Deere DGs (99 kW). Moored, one crewmember on board. Shore power breakers kept tripping, so the port DG ran…Anonymous · 7 mo▲0 rating0 commentsMAN B&W ME-C on VLSFO: which cylinder oil BN to useKnowledgeMain Engine · MAN B&W ME-CThere is no single right cylinder oil BN for MAN B&W ME-C two-stroke engines burning VLSFO (0.5 % sulphur): results depend on the engine and on how it is run. These are my notes from about three…Anonymous · 4 y▲0 rating0 commentsGenerator con-rod seizes and holes the block: oil run far past interval (Ocean Navigator)IncidentAuxiliary Engine · Caterpillar 3516B · ER fire alarm, AE2 low LO pressure and oil filter plugged, blackoutAE2 on a coastal cruise ship (Caterpillar 3516B, 1,800 rpm) had run its LO for more than 5,000 h and its filter elements for 3,329 h. Both should be changed at 1,000 h (LO longer only under…Anonymous · 1 y▲0 rating0 commentsMAN B&W two-stroke: limits for judging engine performanceKnowledgeMain Engine · MAN B&W MC/MC-C, ME/ME-C/ME-BThis is my checklist of practical limits for judging the performance of MAN B&W two-stroke main engines, both mechanical (MC/MC-C) and electronic (ME/ME-C/ME-B). I don't have the source of the limits…Anonymous · 3 y▲0 rating0 commentsFresh water generator: checklist for low output or high salinityProcedureFresh Water GeneratorThis is my checklist for a fresh water generator (FWG) that makes too little water or gives high salinity in the distillate. It applies to a vacuum evaporator heated by engine jacket water, where an…Anonymous · 4 y▲0 rating0 commentsSOx scrubber failure: what to do to stay compliant (MEPC.1/Circ.883)ProcedureOtherWhen the exhaust gas cleaning system (EGCS, SOx scrubber) fails and no longer meets the scrubber guidelines, I follow IMO MEPC.1/Circ.883, which covers EGCS malfunctions. This procedure sets out the…Anonymous · 4 y