▲0 rating0 commentsEngine room fire: fuel backflow through an open return line (Scot Stuttgart)IncidentAuxiliary Engine · "" · ER fire alarm, thick white smoke in port ERChemical tanker with two engine rooms, alongside in San Juan discharging cargo. The port AE was under LOTO for turbocharger and aftercooler cleaning. The crew removed the aftercooler and the fuel…Anonymous · 2 mo▲0 rating0 commentsSwitchboard earth lamps do not light, only one of three on lamp testTroubleshootingElectricalThe insulation resistance monitor (IRM) worked normally. The earth lamps did not light. With the test button pressed, only one of the three lamps lit.Anonymous · 3 mo▲1 rating0 commentsConsilium CS4000: "IOM70 Synchronisation signal" faultTroubleshootingFire & Safety · Consilium CS4000 · CENTRAL 1 IOM70 51 SYNCHRONISATION SIGNALFault alarm on the water mist main panel: "(212) CENTRAL 1 IOM70 51 SYNCHRONISATION SIGNAL", with "PUMP CONTROL BOX - UNIT FAULT INPUTS". On the I/O M70 module: PS LED flashing yellow, COM LED green.…Anonymous · 6 mo▲0 rating0 commentsHi Air Korea AC: compressor will not start, "FRESH ARM 1CRUN"TroubleshootingRefrigeration & HVAC · Hi Air Korea · FRESH ARM 1CRUNThe AC compressor did not start. No alarms were showing. When starting the compressor, only the controller on the AC control panel showed a new alarm: FRESH ARM 1CRUN. The manuals do not explain this…Anonymous · 4 mo▲1 rating0 commentsHyundai HV switchboard: generator VCB tripped, no reset buttonTroubleshootingElectrical · Hyundai HIMAP-BCThe generator engine shut down on lube oil. HIMAP showed reverse power, and the generator VCB (6600 V) tripped. The breaker could not be reset at the breaker. There is no reset button and no handle…Anonymous · 7 mo▲0 rating0 commentsGenerator engine fails on non-OEM bearings run to OEM intervals (Kommandor Susan)IncidentAuxiliary Engine · Caterpillar 3516B-TA · ER fire alarm, blackoutDiesel-electric vessel on sea trials, just out of the lock at Leith with a pilot on board. DG1 and DG4 were on line. The C/E heard a change in engine note on one generator, then a loud bang. The fire…Anonymous · 6 mo▲0 rating0 commentsConsilium CS4000: false fire alarm in cargo hold keeps coming backTroubleshootingFire & Safety · Consilium CS4000 · FIRE ALARM — FIRE ZONE 31 IS-DET 43Fire alarm from a cargo hold zone, but there was no fire. The Fault LED was also lit. After a reset the alarm came back the next morning and then would not reset. A full system restart did not help.…Anonymous · 6 mo▲0 rating0 commentsEmergency generator trips on blackout test, then will not close on the busTroubleshootingElectrical · Schneider Electric ComPacT NSX630Blackout test from the main switchboard: the supply to the emergency switchboard was switched off. The emergency generator started, closed onto the bus and took the load. After 5–10 minutes it…Anonymous · 6 mo▲0 rating0 commentsDual-fuel main engine: loud bangs and many alarms when changing over to gasTroubleshootingMain EngineThe main engine was started and changed over to gas. Loud bangs from the engine and many alarms.Anonymous · 7 mo▲0 rating0 commentsEngine room flooding from a corroded sea water pipe at the strainer (Oliver Hazard Perry)IncidentAuxiliary Engine · John Deere diesel generator · AC power fault alarm on fire alarm panel, blackoutSail training tall ship (128 ft), two Caterpillar C12 propulsion engines, two John Deere DGs (99 kW). Moored, one crewmember on board. Shore power breakers kept tripping, so the port DG ran…Anonymous · 7 mo▲0 rating0 commentsPods stuck at 90° after overspeed trip and a latched water-leak stop (Spirit of Discovery)IncidentPropulsion & Thrusters · Siemens SISHIp eSiPOD (SiPOD-M10) · Pod water leakage stop (WLS) sequence alarm, then propeller overspeedCruise ship with two Siemens eSiPOD pods (6,500 kW each, no rudder), crossing the Bay of Biscay in force 8–9 wind and 8–9 m waves. At 12:30 the port pod gave a WLS sequence alarm. Very soon after, it…Anonymous · 8 mo▲0 rating0 commentsAMS Totem Plus: ME Alpha Lubricator alarms go into inhibitTroubleshootingAutomation / PLC · Totem Plus IMACSAt sea, all ME Alpha Lubricator alarms on the AMS (about 6 channels) went into inhibit by themselves. Real alarms on the Alpha Lubricator panel did not come to the AMS. Alpha Lubricator solenoid…Anonymous · 8 mo▲0 rating0 commentsMAN ME-C: "Low stroke" slowdown, exhaust valve position signal drops outTroubleshootingMain Engine · MAN B&W ME-C · Low strokeMain engine slowdown with "Low stroke" alarm on one cylinder. On the MOP, the exhaust valve position signal from the inductive sensor dropped out about every 3 seconds. Each time, fuel injection to…Anonymous · 8 mo▲0 rating0 commentsAlfa Laval plate FWG: high brine temperature (60 °C) and low outputTroubleshootingFresh Water Generator · Alfa Laval (plate type)Low fresh water output and brine temperature up to 60 °C. Cleaning the plates did not help. Vacuum and heating water were normal. Readings, the same before and after cleaning: Reading Value Heating…Anonymous · 10 mo▲0 rating0 commentsHimsen 6H21/32: lowering the main bearing cap far enough to change the bearingKnowledgeAuxiliary Engine · Himsen 6H21/32When the main bearing cap is lowered with the special tool as the manual says, it goes down only 7–8 cm. That is not enough to change the bearing.Anonymous · 1 y▲0 rating0 commentsAutronica: loop fault on Ex detector stays after barrier replacementTroubleshootingFire & Safety · Autronica, BZB 500 interface unit · LOOP FAULTS: LOOP 01 / POINT FAULTS: 10106 SD(EXI)Open-circuit fault on the paint store detector line. The panel showed "LOOP FAULTS 1 LOOP 01" and "POINT FAULTS 1 10106 SD(EXI)". The system did not see the detector.Anonymous · 1 y▲0 rating0 commentsCummins NTA855 emergency generator: speed hunts ±30 rpm after a cold startTroubleshootingAuxiliary Engine · Cummins NTA855-D(M)On the first cold start, speed hunted by about ±30 rpm at 1800 rpm (frequency by about 0.5 Hz). After a restart (sometimes the 2nd or 3rd) it ran smoothly, and further starts were fine. A few hours…Anonymous · 1 y▲0 rating0 commentsConsilium CS4000: new manual call point gives "No answer"TroubleshootingFire & Safety · Consilium CS4000 · No answerAn old manual call point (P/N 11305) was replaced with the new type MCP-A, P/N 5200030-01A. The system did not find the new unit: alarm "No answer" for its address, although the address was set…Anonymous · 1 y▲0 rating0 commentsAux engine room fire: slipped fuel pump coupling and exhaust leak (Finnmaster)IncidentAuxiliary Engine · Mitsubishi S12R · ER smoke alarm, then blackoutRo-ro leaving Hull with a pilot on board. AE1 had just been paralleled with AE2. Eight minutes after leaving the berth, smoke was detected in the aux engine room. Both AE2 exhaust temperature gauges…Anonymous · 1 y▲0 rating0 commentsAlfa Laval boiler: both HMI panels show "Comm err station 0"TroubleshootingBoiler · Alfa Laval, Beijer HMI · Controller1_TCP: Comm err station 0After the boiler control power was switched off and on, neither HMI panel started working: not the local panel, not the one in the ECR. Both panels showed only the start screen with "Controller1TCP:…Anonymous · 1 y▲0 rating0 commentsFuruno DS-60 speed log: wind, GPS SOG and COG not shown, no alarmTroubleshootingNavigation · Furuno DS-60 (DS-600 display)The speed log stopped showing wind. After the input wires were tightened, GPS SOG and GPS COG also disappeared (dashes on the display). No alarms on the panel or on the screen. All other bridge…Anonymous · 1 y▲0 rating0 commentsBoiler feed pumps air-lock every few hours and trip on low pressureTroubleshootingBoilerBoiler feed water pumps get air-locked. After venting they run for 2–3 hours (sometimes up to 2 days), then the same again. Both pump motors trip. Low pressure alarms on the boiler panel, mostly at…Anonymous · 1 y▲0 rating0 commentsMitsubishi deck crane will not start after a limit switch stopTroubleshootingDeck Machinery · MitsubishiThe crane limit switches were being tested during a class survey. A limit switch tripped and the crane stopped. After that the crane would not start at all. There were no alarms.Anonymous · 1 y▲0 rating0 commentsGenerator will not come off the bus at stop: "Stop failure", reverse powerTroubleshootingElectrical · Stop failureThe undervoltage (UV) coil of a generator air circuit breaker (ACB) was burnt. To keep the breaker usable, the UV coil plunger was held in with its mechanical lock. The generator synchronised and…Anonymous · 1 y▲0 rating0 commentsAalborg thermal oil boiler: no fuel from the nozzle at ignitionTroubleshootingBoiler · Aalborg, LAL burner controlAfter a safety alarm test the boiler stopped and did not start again. The coil of the recirculation (return) solenoid valve had burnt. It had run hot for a long time: it looked melted and its wiring…Anonymous · 1 y▲0 rating0 commentsHoppe valve remote control shows open and closed at the same timeTroubleshootingAutomation / PLC · Hoppe HOMIPOn the HOMIP valve remote control, one electro-hydraulic valve showed "open" and "closed" at the same time. Locally the valve worked correctly and moved fully open and closed.Anonymous · 1 y▲0 rating0 commentsWinGD DF engine: running on VLSFO with a seized pilot fuel pumpKnowledgeMain Engine · WinGD DFThe pilot fuel pump seized. The question was how long the engine can run without it before the pilot injector nozzle holes coke up. The engine ran on VLSFO for 10 days with no pilot fuel supply. When…Anonymous · 1 y▲0 rating0 commentsMain engine: gas bubbles in the fuel system, fuel pressure jumpingTroubleshootingMain EngineAir (gas) bubbles in the main engine fuel oil system. Small bubbles stayed all the time. Fuel pressure was jumping.Anonymous · 1 y▲0 rating0 commentsGenerator con-rod seizes and holes the block: oil run far past interval (Ocean Navigator)IncidentAuxiliary Engine · Caterpillar 3516B · ER fire alarm, AE2 low LO pressure and oil filter plugged, blackoutAE2 on a coastal cruise ship (Caterpillar 3516B, 1,800 rpm) had run its LO for more than 5,000 h and its filter elements for 3,329 h. Both should be changed at 1,000 h (LO longer only under…Anonymous · 1 y▲0 rating0 commentsEngine room fan trips its breaker when the soft starter switches to bypassTroubleshootingRefrigeration & HVAC · Schneider Altistart 48 (ATS48)The main engine room supply fan is reversible and is started by a soft starter with a bypass contactor. The soft starter ran the fan up normally in about 15 seconds. At the moment the bypass…Anonymous · 1 y▲0 rating0 commentsSAM Electronics ME HT cooling: temperature swings 8 °C in autoTroubleshootingMain Engine · SAM ElectronicsThe ME HT cooling water temperature controller (HT cooler valve) could not hold the set point in auto. The temperature went up and down by about 8 °C. Because of this, the system was run in manual…Anonymous · 1 y▲0 rating0 commentsTMC Tamrotor screw compressor: "R:3137 RUN INHIBIT", "check pressure in pipe"TroubleshootingCompressed Air · TMC Tamrotor EMH 21-44 · R:3137 RUN INHIBITThe display showed 6.0 bar and "R:3137 RUN INHIBIT". The manual has only two alarms marked R. For them it says: "check pressure in pipe".Anonymous · 1 y▲0 rating0 commentsNewins IC5000 cold room indicator shows LLLL after resetTroubleshootingRefrigeration & HVAC · Newins IC5000The cold chamber remote temperature indicator read 6 °C different from the real temperature. The settings were reset as the manual says: hold two keys while switching the power on. After the reset,…Anonymous · 1 y▲0 rating0 commentsDiesel oil bunkering: tank overflow through a taped vent, engine room fire (Stride)IncidentBoiler · MAN B&W 7S70MC Mk6 · Diesel oil seen dripping from upper ER; no tank high-level alarm recordedGeneral cargo ship alongside at LaPorte, Texas, taking 80 mt of LSMGO into the port and starboard double-bottom DO tanks. The C/E and 3/E ran the bunkering from the ECR, with both fill valves open.…Anonymous · 1 y▲0 rating0 commentsDoppler speed log: water track vs bottom trackKnowledgeNavigationWater track and bottom track on a Doppler speed log use the same Doppler principle; the only difference is the surface that reflects the signal. This note covers how the log works in each mode.…Anonymous · 1 y▲0 rating0 commentsMooring winch with frequency converter: speed does not change with the joystickTroubleshootingDeck MachineryAn inverter-driven mooring winch stopped regulating speed from the joystick.Anonymous · 1 y▲0 rating0 commentsAC compressor loses oil pressure at start after overhaul with new partsTroubleshootingRefrigeration & HVAC · Low oil pressureThe air-conditioning compressors were overhauled with a new spare parts kit. After the overhaul, oil pressure dropped at every start.Anonymous · 1 y▲0 rating0 commentsBock compressor (AC plant): oil solenoid valve coils overheat and meltTroubleshootingRefrigeration & HVAC · BockAC plant with a Bock compressor. The coil of the oil solenoid valve (220 V, 60 Hz, 10 W) burnt. A new coil heated up very fast and melted. The next coils melted too. Before this, everything had…Anonymous · 1 y▲0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y▲0 rating0 commentsMAN B&W ME: how cylinder prelubrication before start worksKnowledgeMain Engine · MAN B&W MEBackground The engine is a MAN B&W ME-type two-stroke main engine with Alpha cylinder lubricators. The ME hydraulic system pressure drives the lubricators. From the MOP (Main Operating Panel), the…Anonymous · 1 y▲0 rating0 commentsMAN ES two-stroke: why the piston skirt has bronze bandsKnowledgeMain Engine · MAN Energy Solutions (2-stroke)The bronze bands on a MAN ES 2-stroke main engine piston skirt are there to keep adhesive wear on the cylinder liner low when the skirt touches the liner wall. This note explains how they work and…Anonymous · 2 y▲0 rating0 commentsAlfa Laval separator: alarm A85 (MT60 fault), water content shows only dashesTroubleshootingPurifier · Alfa Laval · A85 (MT60 fault)Separator with a water content transducer. The transducer had problems for about two weeks. The transducer board was replaced with a new one. After that, alarm A85 (MT60 fault) came up. The old board…Anonymous · 2 y▲0 rating0 commentsBunker fuel quality: ISO 8217 fuel can still cause engine problemsKnowledgeMain EngineThese are my general notes about bunker fuel quality. They do not describe a real fault on a ship. I give no engine maker, no readings and no test results. I wrote them in two parts. Main point…Anonymous · 2 y▲0 rating0 commentsWestfalia OSD 60-91: bowl does not close, ejection monitoring alarmTroubleshootingPurifier · Westfalia OSD 60-91 · Ejection monitoringTwo main engine LO separators stopped one after the other on the ejection monitoring alarm. On both, the bowl did not close at all. No discharge either, not even a small one. No. 1 stopped 1,000…Anonymous · 2 y▲0 rating0 commentsKangrim boiler: "Flame failure" alarm while stopped, will not resetTroubleshootingBoiler · Kangrim · Flame failureFLAME FAILURE alarm came up while the boiler was stopped (not firing). The alarm could not be reset. A restart did not help.Anonymous · 2 y▲0 rating0 commentsIMO fuel supply pump gives only 5 bar on diesel oilTroubleshootingPumps · IMOThe fuel supply pumps (IMO screw pumps) gave only about 5 bar when running on diesel oil. The ship rarely ran on diesel, so the fault went unnoticed for a long time. It took three months to find.Anonymous · 2 y▲1 rating0 commentsPropeller shaft earthing device: what it does and why it mattersKnowledgePropulsion & ThrustersA colleague asked me what a shaft earthing device does and why it is important. I work on ships, and this is how I explain it. Why the device is needed When the shafting turns, the propeller,…Anonymous · 3 y▲0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y▲0 rating0 commentsRolls-Royce steering gear: "Hydraulic lock" alarm at every small rudder movementTroubleshootingSteering Gear · Rolls-Royce · Hydraulic lock"Hydraulic lock" alarm on the steering gear. It started after a service in dry dock. At first it came now and then. Sometimes it cleared by itself, sometimes tightening the contacts helped. Later it…Anonymous · 2 y▲0 rating0 commentsBallast pump coupling stuck: removed without heat using an extractor and jackTroubleshootingPumpsA stuck coupling flange on a tanker ballast pump can be pulled off without heat using a home-made extractor and a hydraulic jack. That is how we freed ours. The ballast pump sits in the pump room of…Anonymous · 2 y▲0 rating0 commentsSchaller Visatron VN215 oil mist detector: error E 012 a week after serviceTroubleshootingMain Engine · Schaller Visatron VN215/93 · E 012The oil mist detector was fully serviced: optics cleaned, filters changed, negative pressure set as per the manual. One week later it showed error E 012.Anonymous · 2 y▲0 rating0 commentsMAN 6S50ME-B: high exhaust temperature on all cylinders at part loadTroubleshootingMain Engine · MAN B&W 6S50ME-BAt 82–85 rpm (about 55% load; normal sea speed is 90 rpm), exhaust temperature rose on all six cylinders. Exhaust outlet temperatures were 416–437 °C, mean 427 °C. At sea trial this was about 340 °C.…Anonymous · 2 y▲0 rating0 commentsAlfa Laval P615 oil purifier: bowl does not close, PT4 0.00TroubleshootingPurifier · Alfa Laval P615 · PT4 high at dischargeThe bowl did not close for a week. PT4 showed 0.00. A manual discharge gave the alarm "PT4 high at discharge".Anonymous · 2 y▲0 rating0 commentsPanasia PAS-200 isolator: input drops to 6.5 V under loadTroubleshootingAutomation / PLC · Panasia PAS-200New PAS-200 signal isolators (1 input, 2 outputs) were fitted in the cargo control room in place of old ones. With nothing connected, the input voltage was 24 V. With a P/I converter connected, the…Anonymous · 2 y▲0 rating0 commentsDEIF PPM-3: busbar voltage read too low, generator will not auto-synchroniseTroubleshootingAutomation / PLC · DEIF PPM-3The DEIF PPM-3 controller of one generator measured the busbar voltage lower than it really was. The PMS saw a voltage fault. Auto synchronising was not possible, only manual. When the measured…Anonymous · 2 y▲0 rating0 commentsYanmar generators: look-alike turbochargers are not interchangeableKnowledgeTurbocharger · YanmarA ship had three Yanmar diesel generators: two with 1600 kW generators and one with a 1200 kW generator. The diesel engines were the same, and the turbochargers looked the same from outside. But the…Anonymous · 2 y▲0 rating0 commentsCPP hub oil loss from a cracked blade foot, not a blade seal (Maunalei)IncidentPropulsion & Thrusters · MAN Energy Solutions Mark 5 CPP; MAN B&W 7L70MC-C · Engineering alarm, CPP hub head tank found emptyContainership, MAN B&W 7L70MC-C two-stroke ME directly coupled to a 5-blade MAN Mark 5 CPP. On passage to Anchorage an alarm came up: CPP hub head tank empty. The crew reduced pitch and refilled the…Anonymous · 2 y▲0 rating0 commentsAlfa Laval PA605 will not start after emergency stop is releasedTroubleshootingPurifier · Alfa Laval PA605 · Emergency button pressThe emergency stop button was pressed. After the button was released, the pump and the separator would not start. The alarm "Emergency button press" stayed on.Anonymous · 2 y▲0 rating0 commentsISO 4406 vs ISO 4407: oil cleanliness code vs particle countingKnowledgeMain Engine · MAN Energy Solutions ME / ME-B / ME-CISO 4406 is the cleanliness code MAN refers to for main engine system oil on its electronically controlled 2-stroke engines (ME type); ISO 4407 and ISO 11500 are particle counting methods. This note…Anonymous · 2 y▲0 rating0 commentsYanmar generator: HT cooling water outlet 6 °C hotter than on the other engineTroubleshootingAuxiliary Engine · Yanmar (450 kW)Two Yanmar 450 kW generators in parallel, about 300 kW each. Engine HT inlet HT outlet Engine 1 76 °C 80 °C Engine 2 76 °C 86 °CAnonymous · 2 y▲0 rating0 comments220 V insulation alarm every morning, gone before you reach the switchboardTroubleshootingElectrical · Low insulation 220 VLow insulation alarm on the 220 V system early every morning, at breakfast time. By the time the engineer reached the switchboard, the reading was normal again. It started when a new cook joined the…Anonymous · 2 y▲0 rating0 commentsDamcos slop valve shows 67 % when closedTroubleshootingAutomation / PLC · DamcosCargo (slop) valve that can be opened by percent. At 100 % open, the monitor and the local indicator agree. With the valve actually closed, the indicator shows 67 %. When opened to 80 %, the valve…Anonymous · 2 y▲0 rating0 commentsSauer air-cooled service air compressor overheats (105 °C)TroubleshootingCompressed Air · Sauer Compressors, Air Control 1 controllerThe air-cooled service air compressor overheated. The controller showed 105 °C at 5.6 bar.Anonymous · 2 y▲0 rating0 commentsAlfa Laval 856 separator: "Bowl leak" alarm during the leakage testTroubleshootingPurifier · Alfa Laval 856 · Bowl leak"Bowl leak" alarm, but only during the test steps TI 66 or TI 71 (leakage test on fuel). Most often when displacement water was fed. During TI 66 the pressure fell from 1.6 to about 0.4 bar in about…Anonymous · 2 y▲0 rating0 commentsHFO transfer pump: start relay chatters, pump will not start in manualTroubleshootingPumpsWhen Start is pressed, relay 4 in the starter crackles and buzzes. The main contactor does not pull in. The main contactor is new. With one output wire of the control circuit disconnected, the pump…Anonymous · 2 y▲0 rating0 commentsKongsberg K-Chief 600: "ME SBW pot.meter" alarm after lever calibrationTroubleshootingMain Engine · Kongsberg K-Chief 600 · ME SBW POT.METERThe telegraph lever on the starboard bridge wing was calibrated. The calibration went normally. At the next manoeuvring the alarm "Lock in Last 'Speed Set Bridge'" came. It cleared. The alarm "ME SBW…Anonymous · 2 y▲0 rating0 commentsSauer air compressor keeps tripping, nothing found by handTroubleshootingCompressed Air · SauerThe air compressor tripped again and again for about 1.5 years.Anonymous · 2 y▲0 rating0 commentsMAN ME HCU and HPS event logs: compare only with the same engineKnowledgeMain Engine · MAN Energy Solutions ME (electronically controlled)HCU and HPS event logs from the MOP are a useful troubleshooting tool on MAN ES ME engines, but you can only compare events from the same engine. These are my notes on what the events are, how I view…Anonymous · 3 y▲0 rating0 commentsNMF deck crane: no POWER REQUEST after flooding, CPU blinks RUN/STOPTroubleshootingDeck Machinery · NMF crane, Moeller XC-CPU201The cranes were badly flooded: slip rings and control panels. Slip rings and panels were cleaned and dried. The cranes had been without power for 2 days. Cranes 1 and 3 started. On crane 2 the POWER…Anonymous · 3 y▲0 rating0 commentsOceanGuard BWTS: "EUT Power Abnormal" 10 s after startTroubleshootingBallast System · OceanGuard · EUT Power Abnormal AlarmThe BWTS worked normally 3 days before. Now, about 10 seconds after start, the alarm "EUT Power Abnormal Alarm" came up and the system stopped. The EUT power unit got its supply: LEDs on all modules…Anonymous · 3 y▲0 rating0 commentsSEA-Mate B500 blender stops after blending, blend not dischargedTroubleshootingMain Engine · Marine Fluid Technology SEA-Mate Blender B500In auto mode the unit mixes the oils, then stops and stays stopped. It should open the valve and pump the blend on, but it does not. No alarm.Anonymous · 3 y▲0 rating0 commentsOWS 15 ppm monitor cannot detect a blocked sampling lineKnowledgeOWS & Bilge · JOWA; Bilgemon488 15 ppm monitorA 15 ppm bilge alarm without a low sample flow switch cannot tell when its sampling line is closed or blocked, so the OWS can keep discharging overboard. A poorly placed sampling point can also make…Anonymous · 3 y▲0 rating0 commentsFatal engine room fire after opening a pressurised fuel filter (Moritz Schulte)IncidentAuxiliary Engine · MAN B&W L23/30H · ER fire alarmLPG carrier discharging alongside in Antwerp. AE2 and AE3 were running and AE1 was on standby. After the morning toolbox talk the newly promoted 3/E asked the 2/E if he could clean the AE1 fuel…Anonymous · 3 y▲0 rating0 commentsBoiler burner smokes, and more air makes it worseTroubleshootingBoilerThe boiler was smoking. Adding more combustion air made the smoke worse. The burner is set to run on the first stage only. The second stage was switched off on the panel.Anonymous · 3 y▲0 rating0 commentsEltek fire panel: "Fault in addressable loop", but all detectors test OKTroubleshootingFire & Safety · Eltek · FAULT IN ADDRESSABLE LOOP: 01The panel showed FAULT CONDITION: "FAULT IN ADDRESSABLE LOOP: 01". The FAULT lamp was on. The loop worked: the detector test on this loop passed. The manual has no description of this fault. The…Anonymous · 3 y▲0 rating0 commentsIncinerator will not light: thick white smoke, flame sensor drops outTroubleshootingIncinerator & SewageThe incinerator would not light. The flame sensor lost the flame. Before, it had worked every day. The furnace had not been cleaned for a long time. Both chambers were full of ash, and all the air…Anonymous · 3 y▲0 rating0 commentsHyundai steering gear: pump stops 4 seconds after start from the bridgeTroubleshootingSteering Gear · HyundaiIn the evening the running steering gear pump stopped, and the standby pump started. Started from the bridge (autopilot), the pump motor ran for about 4 seconds and then stopped. No alarms on the…Anonymous · 3 y▲0 rating0 commentsCaterpillar 3408 generator will not start after blackoutTroubleshootingAuxiliary Engine · Caterpillar 3408The generator engine stopped and caused a blackout. Dirty fuel filters had let air into the fuel system. After the filters were changed, the engine cranked on the air starter but did not start.Anonymous · 3 y▲0 rating0 commentsMAN B&W ME: HPS pressure build-up time and decay checkKnowledgeMain Engine · MAN B&W MEOn a MAN B&W ME engine with one start-up pump running, I take an HPS pressure build-up time under 30 s as acceptable, and I also check the pressure decay time. The full maker requirements are in the…Anonymous · 3 y▲0 rating0 commentsEmergency generator runs but its breaker will not close on blackoutTroubleshootingElectricalEmergency generator load test: the MSB–ESB transfer breaker was opened. The emergency generator started normally. Its breaker did not close onto the ESB bus.Anonymous · 3 y▲0 rating0 commentsSiemens LOGO! fuel changeover: program loaded but does not runTroubleshootingAutomation / PLC · Siemens LOGO! 230RC with DM8 230R and AM2 expansion modules · Control failThe automatic HFO/MDO changeover (valves and fuel heating) is controlled by a Siemens LOGO! 230RC with expansion modules. A "Control fail" alarm came up on the fuel page of the control PC. Expansion…Anonymous · 3 y▲0 rating0 commentsStandard bearing shell on an undersize journal: con-rods break out (Ocean Guardian)IncidentAuxiliary Engine · Caterpillar 3516B · No alarm; loud bang, then smoke and fire in ERDiesel-electric offshore supply vessel, four Caterpillar 3516B main DGs (1,990 kW each). All four were overhauled by shore technicians in early 2022. On sea trials, DG3 had run about 4 h since…Anonymous · 3 y▲0 rating0 commentsLNG dual-fuel ship: how the fuel gas supply system worksKnowledgeMain EngineThe fuel gas supply system (FGSS) on an LNG dual-fuel ship controls boil-off gas pressure in the LNG fuel tanks and turns LNG into gas for the engines and boilers; its design is set mainly by the…Anonymous · 3 y▲0 rating0 commentsNabtesco governor: main engine will not go above 66 rpm, SCAVEN. LIMIT lamp onTroubleshootingMain Engine · Nabtesco governor control unit · M/E GOVERNOR SYSTEM ABNRThe main engine would not run faster than 66 rpm (Half Ahead). Scavenge air pressure was 0.2 bar. The auxiliary blowers were still running. On the governor control unit the SCAVEN. LIMIT lamp was on.…Anonymous · 3 y▲0 rating0 answersMain engine scavenge drain tank level rising: piston crown O-ring leak suspectedTroubleshootingOpenMain EngineThe level in our main engine scavenge drain tank keeps going up, and I suspect system oil leaking into the scavenge space from the piston crown O-rings. The engine has a scavenge space, so it is most…Anonymous · 3 y▲0 rating0 commentsTwo-stroke liner and ring scuffing: causes, symptoms and monitoringKnowledgeMain EngineScuffing is heavy adhesive wear of cylinder liners and piston rings in two-stroke engines that starts when the oil film breaks down, and it usually comes from several factors acting together. These…Anonymous · 3 y▲0 rating0 commentsRunning the exhaust gas economizer dry: soot fire risk and precautionsProcedureBoilerAn exhaust gas economizer (exhaust gas boiler) can be run dry in an emergency, but the main risk is a soot fire: with no water inside, the tubes run hotter. This procedure lists the precautions I…Anonymous · 3 y▲0 rating0 commentsTwo-stroke main engine will not start without an auxiliary blowerKnowledgeMain EngineA two-stroke main engine (M/E) will not start unless at least one auxiliary blower is running; the control software blocks the start, so in practice it works as a start interlock. The M/E will start…Anonymous · 3 y▲0 rating0 commentsStern tube air seal: risk of losing air supply at deep draftKnowledgePropulsion & ThrustersLoss of the air supply to a stern tube air seal is a serious condition, because at deep draft the oil head alone may not hold back seawater and seawater may enter the stern tube. Loss of air supply…Anonymous · 3 y▲0 rating0 commentsMAN B&W two-stroke: limits for judging engine performanceKnowledgeMain Engine · MAN B&W MC/MC-C, ME/ME-C/ME-BThis is my checklist of practical limits for judging the performance of MAN B&W two-stroke main engines, both mechanical (MC/MC-C) and electronic (ME/ME-C/ME-B). I don't have the source of the limits…Anonymous · 3 y